Loading...
8760_SITE PLAN - 369 MAIN STREET.pdf~7~O ~ (5 t'k P(On- J~q Main 0f-f ttJ- • Town of Agawam 36 Main Street Agawam, Massachusetts 01001-1801 PLANNING BOARD May 8, 2015 Ricardo Sousa Prince Lobel Tel. 413-786-0400 Fax 413-786-9927 100 Cambridge Street, Suite 2200 Boston, MA 02114 Dear Attorney Sousa: -'.", ~ Ul • .D r-' At its duly called meeting held on May 7, 2015, the Agawam Planning Board voted to rescind their Site Plan approval of February 5, 2015 for plan entitled "SBA Agawam Monopole -T- Mobile -Wireless Telecommunication Facility, 369 Main Street, Agawam, MA", dated 12/30/2014, revised 2/4/15 as you requested in your letter dated April 15, 2015. If you have any questions, please contact this office at (413) 786-0400, extension 8737 . . Mark. R. Paleologopoulos, Chairman AGAWAM PLANNING BOARD MRP:prk Cc: Building Inspector, Law Dept., ZBA, Town Clerk, File Pamela Kerr From: Sent: To: Cc: Subject: Attachments: Pam, • Vince Gioscia Wednesday, May 06, 2015 9:39 AM Pamela Kerr 'Jeffrey Fialky' (JFialky@BaconWilson.com) 369 Main Street Planning BD. 369 Main Street Site Plan.pdf • I spoke to outside counsel on the matter. He and I agree that there is no problem with granting the request as attached to this email. Thanks, Vincent F. Gioscia, Esq. City Solicitor Agawam Law Department 36 Main Street Agawam, MA 01001 Telephone: 413-786-0400 ext. 8281 Facsimile: 413-786-9927 E-mail: solicitor@agawam.ma.us 1 ·' • Town of Agawam Interoffice Memorandum To: Vince Gioscia, Town Solicitor and Erik Wight, Building Inspector CC: From : Date: Subject: Planning Board 4/22/15 SBA Tower -369 Main Street Please review and comment on the attached correspondence from Prince Lobel requesting the Planning Board to rescind its Site Plan approval for SBA Towers, 369 Main Street. This item will be placed on the Board's May 7th agenda. prk FROM THE DESK OF ... YOUR NAME TITLE TOWN Of AGAWAM 36 MAIN$T AGAWAM, MA 01 001 Email address Here 4 13·786·0400 X Extension Fax: 41 3-786·9927 - • ~ PRinCe LOBeL April IS, 2015 Deborah S. Dachos Director of Planning and Community Development Office of Planning and Community Development Town of Agawam 36 Main Street Agawam, MA 0 \00 I • Prince Lobel Tye lLP 100 cambridge Street, Suite 2200 Boston, Massachusetts 02] 14 6174568000 main 61 7 456 8100 fax PrinceLobel.com Re: SBA Communications Corporation ("SBA") Wireless Telecommunications Facility Property Address: 369 Main Street, Agawam, MA 01001 (the "Property") Dear Ms. Dachos: On behalf of SBA Communications Corporation ("SBA") and T -Mobile USA, LLC ("T -Mobile" and together with SBA the "Applicants"), this letter, and the attachments, shal1 serve as a request to rescind the Site Plan Review Approval with respect to the proposed modification of the existing wireless telecommunications facility located at the Property dated February 4, 2015 (the "Site Plan Approval"). The Applicants are proposing to modify the existing Wireless Telecommunications Facility located on the existing 170' monopole (the "Facility"). T-Mobile will be upgrading and modernizing its existing facility to provide seamless wireless service, adequate coverage, and capacity to the Town of Agawam and its residents, pursuant to the mandate of the Telecommunications Act of 1996 and its license issued by the Federal Communications Commission (the "FCC") and the Town of Agawam Zoning Ordinance (the "Ordinance"). On March 23, 2015, the Applicants were approved by the Board of Appeals (the "Board") to modify the Facility through the administrative approval process of the Inspector of Buildings (the "Decision"). The Board approved the application to modify the Facility pursuant to the requirement under Section 6409' of the Middle Class Tax Relief and Job Creation Act of2012 (TRA), the Federal statute that requires that local municipalities must approve an eligible facilities request for the modiiication of an existing tower or base station as long as it does not substantially change the physical dimensions of such tower or base station. A copy of the Board's Decision and the Applicant's Section 6409 Eligible Facilities Request are atiached hereto. RECEIVED APR 22 2015 AG14WAM PLANNING BOARD Deborah S. Dachos April 15,2015 Page 2 • • As the Planning Board is a recommending body and the Board has not relied upon or referenced the Site Plan Review Approval or the conditions set forth in the same, in the Board's Decision, the conditions are no longer applicable to the Facility application located on the Property. Moreover, pursuant to section 180-13(b) of the Zoning Bylaws for the Town of Agawam (the "Bylaws") the proposed modification to the Facility does not require Site Plan Review. As such, pursuant to the Bylaws and the Board's Decision, the Applicants will be filing a building permit application directly with the Inspector of Buildings. For the foregoing reasons the Applicants respectfully request that the Office of Planning and Community Development rescind the Site Plan Review Approval dated February 4, 2015 as it is not a condition upon which administrative approval by the Inspector of Buildings is subject to nor did the Board rely upon, reference, or require in its Decision dated March 23,2015. rsousalalprinceiobel.com Direct: (617) 456-8123 2176518.1 • • TOWN OF AGAWAM 36 MAIN STREET AGAWAM; MA. 01001 DECISION OF BOARD OF APPEALS Petition of: SBA Communications Corp. and T-Mobile, LLC Premises affected: 369 Main Street Date: March 23,2015 Case #: 1934 The Board of Appeals conducted two public hearings followed by a public meeting on March 23,2015 for all parties interested in the appeal of SBA Communications and T -Mobile Inc., which is seeking a Special Permit in accordance with Section 180-97 of the Town of Agawam 's Zoning Ordinances which would allow for the construction of a telecommunications tower with less than the required distllDce from the base of the tower to the property line at the premises identified as 491 Mill Street. After the public hearing and a thorough review of the facts presented, the Agawam Board of Appeals made the following findings: I. The subject property is located in an area of town zoned Industrial A. 2. The petitioner is seeking to remove three antennas, replace them and add three more antennas for a total of six antennas. 3. The petitioner will also remove and add cabinets to the existing platform. 4. Section 6409 of the Middle Class Tax Relief and Job Creation Act of 2012 (TRA) mandates that local municipalities must approve an eligible facility's request for modification on an existing tower or base station as long as it does not substantially change the physical dimensions of such tower or base station. 5. The Federal Communications Commission (FCC) has defined substantial change into six major catagories: 1) increases Ileight of tower by more than 10% or height of one additional antenna, 2) protrudes more than twenty feet from the edge of the tower or more than the width of tower structure at level of appurtenance, 3) installation of more than standard number of new equipment cabinets, but not to exceed four, 4) entails any excavation or deployment outside current site, 5) would defeat existing concealment elements or 6) does not comply with conditions associated with prior approval of construction or modification unless non-compliance is due to an increase of height and/or width, addition of cabinets or new excavation that does not exceed corresponding "substantial change" thresholds. 6. The proposed changes to the wireless facility will not increase the height of the tower nor protrude from the edge of the tower more than twenty feet. 7. The proposed number of cabinets and existing cabinets will not exceed four in total . 8. There will be no excavation or deployment outside the existing facility. 9. The proposed changes will not defeat existing concealment elements. 10. There will be no substantial change in the physical dimensions of this wireless facility. DECISION (page 2) Case # 1934 SBA and T -Mobile • • At the request of the petitioner, the petitioner no longer needs to meet with this Board every five (5) years to adj1.L1t the monetary amount of the Removal Performance Guaranty. Instead, the petitioner will send an updated Removal Performance Guaranty to this Board every five (5) years with a cost affidavit to support any change. Thcrefoo: by a unanimous vote of its three members, the Agawam Zoning Board of Appeals turns this matter over to the Inspector of Buildings for administrative approval. This Decision is subject to appeal in accordance with MG.L. Ch. 40A, Section 17 within 20 days after this decision is filed with the Agawam Town Cleric. ~.~~~~~~~ Doreen Prouty a James Marmo • ~ PRinCe LOBeL March 6,2015 VIA UPS AND E-MAIL Ms. Jennifer BOllfiglio Senior Clerk Agawam Zoning Board of Appeals 36 Main Street Agawam, MA a 100 I Mr. Erik Wight Building Inspector Town of Agawam 36 Main Street Agawam, MA 01001 Ms . Doreen Prouty Committee Chairperson, Zoning Board of Appeals Town of Agawam Zoning Board of Appeals 36 Main Street Agawam, MA 01001 ~ / Prince lobel Tye llP ! 100 Cambridge Street, Suite 2200 I Boston. Massachusetts 021 14 I 617 456 8000 main 617456 8100 fa>< I PrinceLobel.com RE: T-Mobile -Section 6409 -Eligible Facilities Request Application, 369 Main Street, Agawam, MA 01001 (the "Property"). Dear Ms. Bonfiglio, Mr. Wight and Ms. Prouty: On behalfofSBA Communications Corporation ("SBA") and T-Mobile USA, LLC ("T-Mobile" and together with SBA the "Applicants"), this letter, and the attaclunents shall serve as an Eligible Facilities Request Application to modify its existing wireless communication facility located on the existing 170' monopole (the "Facility"). T-Mobile will be upgrading and modernizing its existing facility (details of which to be outlined below) to provide seamless wireless service, adequate coverage and capacity to the Town of Agawam, and its residents, pursuant to the mandate of the Telecommunications Act of 1996 and its license issued by the Federal Communications Commission (the "FCC") and the Town of Agawam Zoning Ordinance (the "Ordinance"). The proposed modifications, as depicted on pages A-I, A-2 and A-3 of the attached plans, consist of the following: 2143176.1 Town of Agawam March 6, 2015 Page 2 of4 • • • Replace the existing three (3) panel antennas with six (6) new air panel antennas. • The new antennas will be mounted to new mounts and will be installed at an elevation of 157' feet more or less, the same height as the existing antennas .. • New cabling will be installed and run through the inside of the existing monopole to COlmect the antennas to a new cabinet to accommodate the 2G/3G and 4G equipment modernization. • All of the cabinets will continue to be located on an existing steel platform. Although the Town of Agawam has provisions within the Ordinance that regulate the construction and major modification of wireless communication facilities, the standard of review of an application request for the modification of an existing wireless communication facility on an existing wireless tower or base station has been changed by the passage of an important provision of the Middle Class Tax Relief and Job Creation Act of2012 ("TRA"). The TRA is a Federal Act that was signed into law on February 22,2012. Section 6409 of the TRA requires a streamlined modification and collocation approval process to ensure timely deployment of wireless services. In patiicular, Section 6409 of the TRA mandates that State and local governments must approve an eligible facilities request 1 for the modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. The approval cannot be discretionary if the proposed modification does not substantially change the physical dimensions of such tower or base station2• Further, the Federal Communications Commission ("FCC") under the Nationwide Collocation Agreement (attached hereto as Exhibit 1) defines a substantial change as "the mounting of the proposed antenna would involve adding an appurtenance to the body of the tower that would protrude from the edge of the tower more than twenty feet" or "the mounting of a proposed antenna on the tower that would increase the existing height of the tower by more than 10% ... " Because the proposed modifications at the Facility located on the Property will not increase the the body of the tower nor will the mounting of the proposed antennas increase the existing height of the tower, it is our understanding that the Town of 1 The TRA defines "eligible facilities request" as any request for modification of an existing wireless tower or base station that involves: • Collo<::ation of new transn"lission equipment; • Removal of transmission equipment; or • Replacement of transmission equipment. In the Nation'wide Programmatic Agreemenf for the Collocation q(fVireless Antennas (2001), the Federal Communications Commission ("FCC") defines "collocation" as the "mounting or installation of antennas on an existing tower, building or structure for the purpose of transmitting and/or receiving radio frequency signais for communications purposes." 2 Federal regulations define a "base station" as "[a] station at a specified site authorized to communicate with mobile stations;" or "[alland station in the land mobile service." 47 C.F.R. §§24.5, 90.7 2143176.1 Town of Agawam March 6, 2015 Page 3 of4 • • Agawam, acting through the Building Department, has the right to authorize the proposed modifications of the Facility with the issuance of a Building Permit, pursuant to this Eligible Facilities Request. Moreover, to the extent that the Ordinance requires that the proposed modification request be subjected to a review by the Zoning Board of Appeals (the "Board"), that review is preempted by the TRA. As the Supreme Court stated in Altria Group v. Good, 555 U.S. 70 (2008), a federal law that conflicts with a state law will trump, or "preempt", that state law: Consistent with that command, we have long recognized that state laws that conflict with federal law are "without effect." Maryland v. Louisiana, 451 U. S. 725, 746 (1981). Since the TRA makes approval mandatory if the proposed modification of an existing wireless tower or base station does not substantially change the physical dimensions of such tower or base station, any discretionary review of said modification application would be in conflict with the TRA. Finally, the TRA requires this jurisdiction to issue a final detennination on this Eligible Facilities Request promptly. Accordingly, we respectfully request that you administratively review the subject Eligible Facilities Request application, determine that the proposed modifications do not substantially change the physical dimensions of such tower or base station, and issue all necessary permits accordingly. Please do not hesitate to contact me with any questions, comments or concerns. I thank you for your attention to this matter. Email: rsousa(al.princelobel.com Enclosures 2[43176.1 Town of Agawam March 6, 2015 Page 4 of4 • • Exhibit 1 Nationwide Programmatic Agreement for the Collocation of Wireless Antennas 2143176.1 • • NATIONWIDE PROGRAMMATIC AGREEMENT for the COLLOCATION OF WIRELESS ANTENNAS Executed by The FEDERAL COMMUNICATIONS COMMISSION, The NATIONAL CONFERENCE OF ST ATE mSTORIC PRESERVATION OFFICERS and The ADVISORY COUNCIL ON HISTORIC PRESERVATION WHEREAS, the Federal Conununications Commission (FCC) establishes rules and procedures for the licensing of wireless communications facilities in the United States aDd its Possessions and Territories; and, WHEREAS, the FCC has largely deregulated the review of applications for the construction of individual wireless communications facilities and, under this framework, applicants are required to prepare an Environmental Assessment (EA) in cases where the applicant determines that the proposed facility falls within one of certain environmental categories described in the FCC's rules (47 C.F.R. § 1.1307), inclUding situations which may affect historical sites listed or eligible for listing in the National Register of Historic Places ("National Register''); and, WHEREAS, Section 106 of tile National Historic Preservation Act (16 U.S.C. §§ 470 el seq.) ("the Act") requires federal agencies to take into account the effects of their undertakings on historic properties and to afford the Advisory Council on Historic Preservation (Council) a reasonable: opportunity to comment; and, WHEREAS, Section 800.l4(b) of the Council's regulations, "Protection of Historic Properties" (36 CFR § 800.14(b», allows for programmatic agreements to streamline and tailor the Section 106 review process to particular federal programs; and, WHEREAS, in August 2000, the Council established a Telecommunications Working Group to provide a forum for the FCC, Industry representatives, State Historic Preservation Officers (SHPOs) and Tribal Historic Preservation Officers (THPOs), and the Council to discuss improved coordination of Section 106 compliance regarding wireless conununications projects affecting historic properties; and, WHEREAS, the FCC, tbe Council and the Working Group have developed this Collocation Programmatic Agreement in accordance with 36 CFR Section 800.14(b) to address the Section 106 review process as it applies to the collocation of antennas (collocation being defined in Stipulation I.A below); and, WHEREAS, the FCC encourages collocation of antennas where technically and economically feasible, in order to reduce the need for new tower construction; and, WHEREAS, the parties hereto agree that the effects on historic properties of collocations of antennas on towers, buildings and structures are likely to be minimal and not adverse, and that in the cases where an adverse effect might occur, the procedures provided and referred to herein are proper and sufficient, consistent with Section 106. to assure that the FCC will take such effects into account; and WHEREAS, the execution of this Nationwide Collocation Programmatic Agreement will streamline the Section 106 review of collocation proposals and thereby reduce the need for the construction of new towers, thereby reducing potential effects on historic properties that would otherwise result from the construction of those unnecessary new towers; and, • • WHEREAS, the FCC and the Council have agreed that these measures should be incorporated into a Nationwide Programmatic Agreement to better manage the Section 106 consultation process and streamline reviews for collocation of antennas; and, WHEREAS, since collocations reduce both the need for new tower construction and the potential for adverse effects on historic properties, the parties hereto agree that the terms of this Agreement sbould be interpreted and implemented wherever possible in ways that encourage COllocation; and WHEREAS, the parties hereto agree that the procedures described in this Agreement are, with regard to collocations as defined herein, a proper substitute for the FCC's compliance with the Council's rules, in accordance and consistent with Section] 06 of the National Historic Preservation Act and its implementing regulations found at 36 CFR Part 800; and WHEREAS, the FCC has consulted with UJe National Conference of State Historic Preservation Officer.; (NCSHPO) and requested the President of NCSHPO to sign this Nationwide Collocation Programmatic Agreement in accordance with 36 CFR Section 800.14(b)(2)(iii); and, WHEREAS, the FCC sought comment from Indian tribes and Native Hawaiian Organizations regarding the terms of this Nationwide Programmatic Agreement by letters of January 11,2001 and February 8, 200 I; and, WHEREAS, the terms of this Programmatic Agreement do not apply on "tribal lands" as defined under Section 800.16(x) of the Council's regulations, 36 CFR § 800.l6(x) ("Tribal lands means all lands within the exterior boundaries of any Indian reservation and all dependent Indian communities."); and, WHEREAS, the terms of this Programmatic Agreement do not preclude Indian tribes or Native Hawaiian Organizations from consulting directly with the FCC or its licensees, tower companies and applicants for antenna licenses when collocation activities off tribal lands may affect historic properties of religious and cultural significance to Indian tribes or Native Hawaiian organizations~ and~ WHEREAS, the execution and implementation of this Nationwide Collocation Programmatic Agreement will not preclude members of the public from filing complaints with the FCC or the Council regarding adverse effects on historic properties from any existing tower or any activity covered under the terms of this Programmatic Agreement. NOW THEREFORE, the FCC, the Council, and NCSHPO agree that the FCC will meet its Section 106 compliance responsibilities for the collocation of antennas as follows. STIPULATIONS The FCC, in coordination with licensees, tower companies and applicants for antenna licenses, will ensure that the following measures are earned out. I. DEFINITIONS For purposes Oflhis Nationwide Programmatic Agreement, the following defmitions apply. A. "Collocation" means the mounting or installation of an antenna on an existing tower, building or structure for the purpose of transmitting and/or receiving radio frequency signals for communications purposes. 2 • • B. "Tower" is any structure built for the sole or primary purpose of supporting FCC-licensed antelUlas and their associated facilities. C. c£Substantia1 increase in the size of the tower" means: I) The mounting of the proposed antenna on the tower would increase the existing height of the tower by more than 10%, or by the height of one additional antenna array with separation from the nearest existing antenna not to exceed twenty feet, whichever is greater, except that the mounting of the proposed antenna may exceed the size limits set fOlth in this paragraph if necessary to avoid interference with existing antennas; or 2) The mounting ofthe proposed antenna would involve the installation of more than tbe standard number of new equipment cabinets for the technology involved, not to exceed four. or more than one new equipment sbelter; or 3) The mounting of the proposed antenna would involve adding an appurtenance to the body ofthe tower that would protrude from the edge ofthe tower more than twenty feet, or more than the width of the tower structure at the level of the appurtenance, whichever is greater, except that the mounting oftbe proposed antenna may exceed the size limits set forth in this paragraph if necessary to shelter the antenna from inclement weather or to connect the antenna to the tower via cable; or 4) The mounting of the proposed antenna would involve excavation outside the current tower site, defined as the current boundaries of the leased or owned property surrounding the tower and any access or utility easements currently related to the site. II. APPLICABILITY A. This Nationwide Collocation Programmatic Agreement applies only to the collocation of antennas as defined in StipUlation I.A, above. B. This Nationwide Collocation Programmatic Agreement does not cover any Section 106 responsibilities that federal agencies other than the FCC may have with regard to the collocation of antennas. m. COLLOCA nON OF ANTENNAS ON TOWERS CONSTRUCTED ON OR BEFORE MARCH 16,2001 A. An antenna may be mounted on an existing tower constructed on or before March 16,2001 without such collocation being reviewed under the consultation process set forth under Subpart B of 36 CFR Part 800, unless: I. The mounting of the antenna will result in a substantial increase in the size ofthe tower as defined in Stipulation I.C, above; or 2. The tower has been determined by the FCC to have an effect on one or more historic properties, unless such effect has been found to be not adverse through a no adverse effect finding, or if found to be adverse or potentially adverse, has been resolved, such as through a conditional no adverse effect determination, a Memorandum of Agreement, a 3 • • programmatic agreement, or otherwise in compliance with Section 106 and Subpart B of 36 CFR Part 800; or 3. The tower is the subject of a pending environmental review or related proceeding before the FCC involving compliance with Section 106 of the National Historic Preservation Act; or 4. The collocation licensee or the owner of the tower has received written or electronic notification that the FCC is in receipt of a complaint from a member of the public, a SHPO or the Council, that the collocation has an adverse effect on one or more historic properties. Any such complaint must be in writing and supported by substantial evidence describing how the effect from the collocation is adverse to the attributes that qualify any affected historic property for eligibility or potential eligibility for the National Register. N. COLLOCATION OF ANTENNAS ON TOWERS CONSTRUCTED AFTER MARCH 16,2001 A. An antenna may be mounted on an existing tower constructed after March 16,2001 without such collocation being reviewed under the consultation process set forth under Subpart B of36 CFR Part 800, unless: I. The Section 106 review process for the tower set forth in 36 CFR Part 800 and any associated environmental reviews required by the FCC have not been completed; or 2. The mounting of the new antenna will result in a substantial increase in the size of the tower as defined in StipUlation I. C, above; or 3. The tower as built or proposed has been determined by the FCC to bave an effect on one or more hisloric properties, unless such effect has been found to be not adverse through a no adverse effect finding, or if found to be adverse or potentially adverse, bas been resolved, such as through a conditional no adverse effect determination, a Memorandum of Agreement, a programmatic agreement, or otherwise in compliance with Section 106 and Subpart B of36 CFR Part 800; or 4. The collocation licensee or the owner of the tower bas received written or electronic notification that the FCC is in receipt of a complaint from a member of the public, a SHPO or the Council, that the collocation bas an adverse effect on one or more bistoric properties. Any such complaint must be in writing and supported by substantial evidence describing how the effect from the collocation is adverse to the attributes that qualify any affected historic property for eligibility or potential eligibility for the National Register. V. COLLOCATION OF ANTENNAS ON BUILDINGS AND NON-TOWER STRUCTURES OUTSIDE OF HISTORIC DISTRICTS A. An antenna may be mounted on a building or non-tower structure without sucb collocation being reviewed under the consultation process set forth under Subpart B of 36 CFR Part 800, unless: I. The building or structure is over 45 years Old;' or I Suitable methods for determining the age of a building include. bUI are not limited to: (I) obtaining the opinion of a consultant who meets the Secretary of Interior's Professional Qualifications Standards (36 CFR Part 61) or (2) 4 • • 2. The building or structure 1S inside the boundary of a historic district~ or if the antenna is visible from the ground level of the historic district, the building or structure is within 250 feet oftbe bcundary of the historic district; or 3. The building or non-tower structure is a designated National Historic Landmark, or listed in or eligible for listing in the National Register of Historic Places based upon the review of the licensee, tower company or applicant for an antenna license; or 4. The collocation licensee or the owner of the tower has received written or electronic notification that the FCC is in receipt of a complaint from a member of the public, a SHPO or the Council, that the collocation has an adverse effect on one or more historic properties. Any such complaint must be in writing and supported by substantial evidence describing how the effect from the collocation is adverse to the attributes that qualify any affected historic property for eligibility or poteotial eligibility for the National Register. B. Subsequent to the collocation of an antenna, should the SHPOffHPO or Council determine that the collocation of the antenna or its associated equipment installed under the terms of Stipulation V has resulted in an adverse effect on historic properties, the SHPOrrHPO or Council may notify the FCC accordingly. The FCC shan comply with the requirements of Section 106 and 36 CFR Part 800 for this particular collocation. VI. RESERVA nON OF RIGHTS Neither execution of this Agreemen~ nor implementation of or compliance with any tenn herein shall operate in any way as a waiver by any party hereto, or by any person or entity complying herewith or affected hereby, ofa right to assert in any court oflaw any claim, argument or defense regarding the validity or interpretation of any provision of1he National Historic Preservation Act (16 U.S.C. §§ 470 et seq.) or its implementing regnlations contained in 36 CFR Part 800. VII. MONITORING A. FCC licensees shan retain records of the placement of all licensed antennas, including collocations subject to this Nationwide Programmatic Agreement, consistent with FCC rules and procedures. B. The Council will forward to the FCC and the relevant SHPO any written objections it receives from members of the public regarding a collocation activity or general compliance with the provisions of this Nationwide Programmatic Agreement within thirty (30) days following receipt of the written objection. The FCC will forward a copy ofthe written objection to the appropriate licensee or tower owner. VIlI. AMENDMENTS If any signatory to this Nationwide Collocation Programmatic Agreement believes that this Agreement should be amended, that signatory may at any time propose amendments, whereupon the signatories will consult to consider the amendments. This agreement may be amended only upon the written concurrence of the sigoatoTles. consulting public records. 5 • • IX. TERMINATION A. If the FCC determines that it cannot implement the termS of this Nationwide Collocation Programmatic Agreement, or if the FCC, NCSHPO or the Council determines that the Programmatic Agreement is not being properly implemented by the parties to this Programmatic Agreement, the FCC, NCSHPO or the Council may propose to the other signatories that the Programmatic Agreement be terminated. B. The party proposing to terminate the Programmatic Agreement shall notifY the other signatories in writing, explaining the reasons for the proposed termination and the particulars of the asserted improper implementation. Such party also shaJl afford the other signatories a reasonable period of time of no less than thirty (30) days to consult and remedy the problems resulting in improper implementation. Upon receipt of such notice, the parties shall consult with each other and notify and consult with other entities tbat are either involved in such implementation or that would be substantially affected by termination of this Agreement, and seek alternatives to termination. Should the consultation fail to produce within the original remedy period or any extension, a reasonable alternative to tennination, a resolution of the stated problems, or convincing evidence of substantial implementation of this Agreement in accordance with its terms, this Programmatic Agreement shall be terminated thirty days after notice of termination is served on all parties and published in the Federal Register. C. In the event that the Programmatic Agreement is terminated, the FCC shall advise its licensees and tower construction companies of the termination and ofthe need to comply with any applicable Section 106 requirements on a case-by-case basis for collocation activities. X. ANNUAL MEETING OF THE SIGNATORIES The signatories to this Nationwide Collocation Programmatic Agreement will meet on or about September 10, 2001, and on or about September JO in each subsequent year, to discuss the effectiveness of this Agreement, including any issues related to improper implementation, and to discuss any potential amendments that would improve the effectiveness oflhis Agreement. Xl. DURATION OF THE PROGRAMMATIC AGREEMENT This Programmatic Agreement for collocation shall remain in force unless the Programmatic Agreement is terminated or superseded by a comprehensive Programmatic Agreement for wireless communications antennas. Execution of this Nationwide Programmatic Agreement by the FCC, NCSHPO and the Council, and implementation of its terms, evidence that the FCC has afforded the Council an opportunity to comment on the collocation as described herein of antennas covered under the FCC's rules, and that the FCC has taken into account the effects of these collocations on historic properties in accordance with Section 106 of the National Historic Preservation Act and its implementing regolations, 36 CFR Part 800. • • FEDERAL COMMUNICATIONS COMMISSION _________________ Date: ________ _ ADVISORY COUNCIL ON HISTORIC PRESERVATION _________________ Date: ________ _ NATIONAL CONFERENCE OF STATE HISTORIC PRESERVATION OFFICERS _________________ Date: ________ _ 7 • • Exhibit 2 Plans by SBA Communications Corporation, dated July 21 ,2014 SGOPt or ~ Slr! .ADORts!, LO.TITUO[; 1.0Na'lLJI)(, JlJR!SDlCIIOH: ZON1NC ~~IS~CfIO~. elll'lll£~t vst: PROl'O'3[~ ~[, DESlCr. CIJ«l'~t' TOWII: ewr<E~, SIM SITt 10, SB/I 0141.1[, T.. MUVltlt U''''MlCO l[~(alII~TIOIIS rlOll1Y T-II08II.[ (OUIPU(HT uoot.'Ul'TION Jst foO'IN !I11£f'T -'G4'*''''. W. 011)01 '2' OS' 02.1' N (!SII RECORD) 12' le' ca.," W (SIIII ft[COltO) ""'"0Not.I., STAn: .. lOC,IJ. coors OR O!lOlW.HCES a'IHI;I I;IN INfC~I.IATDI ~RtMDllI !'r T_t.DIIU. nus ltLE~OM~\lNltA1IDNS ~If'M[~l 1;I[P'll;fl'1.ltHT I::; oil! ElIQ~,( fAC'1JIY \lMOt/l l~' TAX RtLIO' ACT cr 2012 •• 7 11K HS6{ll. NIP) ~ SUBJtCT ;1;1 ..... ExProTEO (llQetE fl.ClUflU Rl OuUT/It£Y1l'" NOn ~0Hi1\(l P1'I[_(MPOOH rOil ~ Dl$l:RC1IOHM'f Pt~1lm (yAAIUIIX, speCIAL ~ERl.llt. !11T( ~LJ,H ~C'o'ICW). ItL'l:Ot.o~1oHCA11OHS rltClUTY Itl~Tte!t$ rACIlITY .. '(1.< TOW(1I'i .. u.c ..... 'J~4. /oClfiY-1A/iIlV'S (ON.' GIHtllAU<'OI"I5 10·1 COM' __ .. iVCIa.eY"TQN .. , •• .. M ,., ., _0<5 ..... :)AHTt"Ju. 'CHWUl.U .OOI"""',.,~ ..... DCl.t0.5 ott.,I.' '_"'"T~"III f:CI\I"'''''"T~'fI ,., O!l.OII"OIl .. O. olle"" .. ! OWl!\l\fIII' on.lLt C(lNSTRIIC'TION ~" OPERAllO!<S __ ., ... IIm. .... Peter Nute, SBA .,.. ... -";'~.~~ ... ttl £M!:lN££JI:,wt ~" TOWEll: OWNER DATE l~ I Sitt /(0. ~" .f11:U " .... '. -..... ~ ~'··h I'IIO.-c:T *, .. I--~~;;t~, SITE NAME: SBA AGAWAM MONOPOLE 369 MAIN STREET AGAWAM, MA 01001 SITE NUMBER: 4SH M026A -~.~,~, .J,e .".' .. Ttl., llCIC\IW(.'It '" no( «EA'I'ICIOl. 0£5IGH. "1IOP(1ffY NOC ID"tIIICHTfD WIftI at r.1i08I£ ~. uc. ~ ~T!0f4 011 OR: 0Ii1H0UT EltPI\LSS ~ OIINSL'Ir IS STM:tl'l' I'!IOtIeIIRI. 0IA'lJC0+J1OW No(l USt 8'1' COIItIINWDil ,\Wi~n rOIl nu: ~ or COHOOC'!\IIC neR tHoflAl'o' .wJIIOIIIlt'O ill:&\IIJ.fOII\' AICl ~'Nt ~ 15 sPtClfOl~Y N.Ul'JI'El). JIll: FJ«JlY IS .vi IIN_!I(D ..-I( "I'tO s£c~ EDUII'Utl'ff l!<Sl.ouAl>CnI. It I:) CIIIl'l' AC«SSaI Irr """t«CI ~15 0'I)It O'(I\I:I:lIC IIGt/T1Nt _I{~ _ 1~(1I1J0Itf. ooa lICIT II£OUfI{ ~ ..... 1[11: ()fI s.«n.oRr SOlO S(lNCt. J10If '''''"''' IS 1101 ~II n 1I(W\Al!CMS II(QUfJIC I'UIILC .ACCUS P(II _ 1I(0WIE1oI(JfIS. NIl ctlllOIIOfI IlU'll£'$(NT,\,TIY( IN M~ 1. Tl1I'I!ft 00111( ............ I'IItMOf 0l.0lI0\I. STl'IIICT1JIUI. sr""",t1Y 1IHIoI."'S15 or f;XmINI:< AMn:~ ... 'iII'lIlfI STlIVCTURt. CEHER/Il C0MIlIAC1OR SCQI'[ or WOItI( SlWl. I'ICl.IJOt IILl rttlNl/IOl !II1UCTlJIW. IoIOOII'lCIoTll).'fS. 1l[-IIUW[)lIHC IIr to.\XtAl C41.U OIl on.!1I: ~[c ..... IOIQOIt'C.t.TXl/IS "'! O\Jf\I!ICO l>>CR(1)i, Z. SflWc:"lIlIAI.. ot~ "'*I) DtT/o.1U5. fD~ ""ltM ..... WOU~lS ~O ... 1'LUI1l rf PltCnUA ots~~ C1tOul'. LtC. 011 !D\Al~ Of r-~Il£ ME IIICl.VSfIE or Tilt [HTlllt ..... UIHl~ Sl$Ipoon lT~uervft[ (OLOllo'<!. !5TRUCTUIW. STA!JjUJY I.IW,l'S15 II'! ::k~' ~~~~Os=:i"'~rlolw,J.XI~:O~T~~N.t.,~~:l ~~[t~J~~ (Q\JIPQIN'T D[~U7I'II[NT .AS otPlCllO H[~[IN. ® DIG SAFE SYSTEM I"", ME, NH, RI, VI), 1-888-344-7233 CAll BEfORE YOU DIG (el): 1-800-922-H55 * UNDERGROUND SERVICE ALERT • • '" ~ z :;i ffi iii " • • • Ii ~ ~ ~ • > § e ~ • ~ 0 -E >. E Et • z !2 • I-"S-c( siii C .J ~ III ~ " :: z . ~ i=",'; ;: -., "X ri Wen 2 -~ z ::I !1. 0 ~ , { (El f-MOBllE P.l.NEL ANlENNAS TYI', or {ll \.~, pm SECTOR. (J) TOTAl. , TO BE REI.1OVEO (El MO~OPOI.E~ (E) SN'CTY cUlm <::s '" CliMBINC PEes #f ~ EXISTING ANTENNA PLAN @ ~LE:-;-;'!.·-("i-i;i7) ;·"2,~' (12-.J4j j..."",§"~'_;;;!"",~"",:=: ,-, (~a.: ~ B~~g"J" ,,' """ SECIOA k SECTOR Il: SEOOR ~ ..". SE!;'IOR A:, $£Cloo e: ,,~o fXI5UNC ANTENNA $CHErn II E !:1m ~ ~ KAf~EIf<j eOO-l0~0& U."2.h)a ~"'TfIII£1I< 100-1051)< e.h2.7.~ KATMlI[1H ~OO_10S!J' G.'d.'.~' PROFOSEQ MUfNNA 5GHFPI!! f '"" """" ""-""""1 ERIC'S501j "~ZI 1!2/0/~"~ 12.7.e..,~., (~ICSS~ AI~21 B~A/~2P t2.7.ed~.' ERIeSSON AI/l21 a2,O/o,p Eft1C'S5D>1 AI~Z1 !l'~/B2P E~ICS!OH IIIR21 82NB~P E~IC'SSO>I AI~21 BU/BV' "'" ,. ~ffV! III ~ ftf I)<,T~ SI1([! roll '2.7.!·5~.' \7.7.a.~., 12'7.0.".' !2.7.a.55.' (P) T-NlU ~BLY (!rrePRO . !'ART 'I,IDS-NP) TO REPU.CE (E) I.IOI1HTS (El NONOPOlE (p) 2-'~· SCH40 (1-7{t~GO~~ SUf'PORT PIPE TIP. (2) PEl!. stCTO~ {e TOTIQ , (P) AlR11 ~ fl.J'\ ~W~~~ (P) 'T!.AA. TYP. OF (1) PEIl SECTOR. (3 TOTAL) LOCAlED ON IHItNN.I, PIPE J.IOUNT (El SoIJ'E'O' CLIMB ole C~lt.lBING PEGS Fl"",,~Sm'l...:s. @ PROPOSED ANTENNA PLAN ffiCPl RBo\72 \BJ , @ -... -... / PROPOSED eaUlPMENT AREA SeALE, 1" .. !' (11017) 1"",2,$' (22'''9 2.5 ~CAI..~, 1· .. i!I·-(~ ,-, 1· .. 2.~' (22,J4) l:""",~"~'iii;;;!~""'~~ ,., , • • (~) m ~Nrr )0 Ir M:OIQYrO (t) lOp<: @ EXISTING EQUIPMENT FRAME SCALE; l" .. :r (lht'1) ,"",,' (n.J~) AU. f1W« "lJDI.KI\ON$ NCI ~ltIoe:COWlmD PRIOR 'IU INSTAUIiOOH OF PRDf'OSUl ~~~mn.MAS I FIIl£s~ -IIMJR!E'''' I (E) !tAR CRIoTINC--.[ let 1Jfro~ 'GO"'" @ SIl'E NUMBEA: srre: N.6I.e SBANJAWAM • @ 'a l! -{PJ {IJ 1-.1/11-IMIRD '\ • CA8l£ (FIlU.OW (!) CQ,U[ AI , ..... CAal£S TO ..INf'DINU) ICE: IllAlOO~ -\1:./ IOl'I; "'" M:. ~~UAl ~~~_~~TO PROPOSEO EQUIPMENT FRAME sCAli;: 1".2' (1\,;\7) ," .. ,' (U~34) ,-, • • "-'ACE S~CE, ~~OlE~~'" O=>/20/U :t~:T!i.~ ANTENNA MOUNT, TYP. @ : ji •. (~)~~,:'~~'" l'I'P.~(2}m ~ I. 'ITmU\ @ 1l0l00 1OOU>lll:.g III "'E ,~~--~----ittO. ,-. ~. ·Mobile- T.M08ILE NOATHWT LLt '$~"'Y.SUllt. ---. W. Dlln It.IAct SOURCE: 1'1t01E~1tt. 05n9/1~ PROPOSED ANTENNA MOUNT, TYP. t.: IV.5. • H • --""'"--:\ (j 1--"" J 1=;;:::'''0'"= ......ti I , '1 r !!ii"."" •. " ""I'" ~'ilgr _ I 'If ?2j't!:!". ',. ,fl¥ ;.ca;:".,,,,, ... "1 """-"'" bt.~~ ~T~1,,\1t MM'Jr...cTUI'I(ft'$ I'ItCO~"'ENC"'lIONS J"l ", :1" " 1 U I I I " ~"'"~ ""'-"'" ~ j" 55 011 /o,US ~y. !OI.1'5 ~tll! W,NvrACfIJR(!II'$ 't(t:OIoolI.l(NOJ,ItON$ t--:;;---3;1..)" ------;;;I rfI I'J 00 L-I ----1 o o o o o o o o o 0 ""-"'" RBS 6201 CABINET ~~!-TA ENCLOSURE @ \l!A"~ CABINET DETAIL @ ql. ·Mobile· T.MOBILE NORTHIAll LLC • • • • • ~ , ~" ~ , • ~ ii~ ~ I E .\:~ • I ~ ,. • •• ~ , ." ~ ~ " g ~ " ~a!:!~~ a~~ .~~~.O ~. ~ig ';~3.~i;/\:i' <0· ~ .... ut:~ ~ ~~~ ~ "aa"~, -.~~8" • ~fI.~ " tt .... o'* @ H::'~-g =-~s g __ 0 --,'" • 0--" .~ ~~i~1 ii~ ~= i iii -tl •• ~ ~~= ~~ I=~~ ~ ~,~wl ~~d; ~~~r~ i~~~~ ~~;;~~ ill ~ ~. ~ ~~ ,; E~ E o .1 • .' . -,( -.' • " " , . """ ~ "" " C(lt.lNEC~~. WELO-'::"~ '" "" I.\~C~.OJII~ C;QNN(CTlON, TYP. r~"' ~'rS{81WCf. r~'''~ """"" jl ~;4:: j (-" KO =:::~ 7~ ca TO '~RO\J~ RINe: ~ _ .!2~. __ ----..,., TO HISr. CROUI'/O j .. CONNECTION "CO ;,x}'!?tL GROUND RISER DIAGRAM @ ~,=\~ COU .JU),IfI[FI (~.) ~ 11 -.a..T\'IQI~C: 1m (7YP.J """"" ClIOUNo I(IT (TYP.) """".-' -¥--"tIt(NNA CAel.E W£tl.TfIERPRoonNC to Cr\8U: TltAy KIT (m>,) (TYP.) r':';~ ~=---........ co...: ClIO'JNII ~lT , • COI.IM5CCPE ICIT NO. CI·oo,14..(f 011 £0tW.. 1. DO NOT ~:n ... u. GAelt eltOUIIO J(ff ... , A. I!'EHO MO (2 MI'C SCII', 8OHO£D 70 CAQVNO 1I'IIIE AtOtll 008\,.i; lftoo,y TO ClGl!(jtIICg AtWoYS ON HC'\' GJlOuNO 'l11li£ OO'ol/H TO Clcer. GROUND WIRE TO IDI!iH.l IWIOWNK TWO HOI£ COI"PU CQVPR£SSlOIf l(R1,11lW. tit" fUD(A$ IN COHDtlJI' SIlEO It.' ACtQAOlo.'<C ..... """'" ==rifr CIIO'..f<OI*: c.oetE W/llWlUF...cTtJRff!S R(()()W"(~noH$ IN,) B.-TTER'I' STRING COfI'nGVAATlON lO lit .. GIIOJID eAA lJtT(hUNtD BY 1-1010611..[ LOClt ''''...sHEII'~~I.AT \VASilE!!, TYP. mo, J/!-.I-I/~. Il[~ BOLT NUT. TrP. CRO\ll«l !WI (Xl"OSED &/OfiE coPPER 00 If[ C~ CIa! I<U'T H) "'ISO\,.UT( IoI.WIIoIVM, foIO IN$UWOI AUO'IJ[!) ,.,TMN lME "'"'" ~SIOH 1~ (M'OI.) 1. 'OO:flUHt I,.or" M "'STACIOI'IC -or COHN(CTICI!\I IS HOT PElbanm. 2. OXIO£ INMIIPINC CO¥PCl\JMll TO II( US(!) "T .ou. LCIao'JlOlolS. 3. ~ IX:7Mf..tACS ntOM IJPP(iI ~, LCIW[II; £ca. -'NO wc:e. " .... l CIIOI.KI LUGS WIJST !IE: i'l£At Sl<1IUN~ "1 WIIU!WQ COI'fN(CTI<»I A8o\7t CA91H(T otLlA "".~ W/IN'I'£R1OR U~1 TYPICAL GROUND ~,e~,f.0NNECTION DETAIL 0 gS,~,~E-LINE SCHEMATIC ® It/SEIMC( , /oI£1!~ ",{Ioo-. .. f?Np=LT~ .. TQ ~;g:"'r(' n~ .. oo""" <" ", .. , ~ "" UWI $! -TIWl~(I) 112 AWG T £.1.WN.o.I. IIIl!~'~ .""" ~ '" ... " ""'" '"'' ' :---6~OI c.o.BMl -:I~J( ''''''.. ! , /1:h"" ... '" '" _,.,."'" -, '~ , .. y ~/'~~~'<~"~_"_-::=:::-__ I ..... ']..., . <0 '" . ""',.", ,., 1>4'-'" ,,,.,, : tQHOtJCfORS Rt:QLWlEC 1M ACOOJlnANCE WITH NEe :." . (~·t.l0VE) I I.IPPPC(3) I . R[f'[EO (£) '~,~ AWC·CU 6OA~2" l •' .. , ". 'I"~ "'"... r-.. .,'" " ,-, , """IT '. . ...... eO~1Ttt.Cl0,A ~~NO 1oI!E1 N~ 'I~~ ,. $U~Qf (l " AWC tv .. (') ""m " "'''''. P~~-~.~ + .. Gf1 t~,~COH(UT , "'l -, $(IMC(,,~ , ONE LINE POWER DIAGRAM $~t: N.T.!. tIl --Mobile- @ • • • • • Town of Agawam 36 Main Street Agawam, MassachnsettsOlOOl-1837 February 17, 2015 SBA Towers II, LLC 33 Boston Post Road Marlborough, MA 01752 RE: Revised Approval Letter To Whom It May Concern: Tel. 413-786-0400 Fax 413-786-9927 C-, UJ At its duly called meeting held on February 5, 2015, the Agawam Planning Board voted to approve the Site Plan entitled "SBA Agawam Monopole -T-Mobile -Wireless Telecommunication Facility, 369 Main Street, Agawam, MA; prepared by Pro Terra Design Group, LLC" and dated 12/30/2014, revised 214/15. This vote was conditional upon all professional staff comments (attached) being addressed. If you have any questions, please contact this office at 786-0400, extension 8738. Mark R. Paleologopoulos, Chairman AGAWAM PLANNING BOARD MRPIDSD:prk i- • • AGAWAM OFFICE OF PLANNING & COMMUNITY DEVELOPMENT SITE PLAN REVIEW REVIEWER: D. Dachos DATE: February 4,2015 DATE RECEIVED: January 12. 2015 DISTRIBUTION DATE: January 13,2015 PLANNING BOARD MEETING DATE: February 5, 2015 APPLICANT INFORMATION 1. Name of Business: SBATowers II, LlC Address: 369 Main Street, Agawam 2. Owner: SBA Towers II, LtC Address: 33 Boston Post Road! tvtarlborough, MA 01752 Telephone: 50B-251-0720 · 3. Engineer: ProTerra Design Group, LLC Fax: . Address: 4 Bay Road, Building A, Suite 200, Hadley, MA 01035 Telephone: 413-3204918 FaIC: PlAN REVIEW Scale: 1" = 100' Date: December 30, 2014 TItle Blode (Street Address. Applicant's Name. Address. Scale. NIlr:ne of Preparer of Plan): O.K. Desalptlon of Project: T-Mobile wishes to upgrade its equipment on the tower and in the premises. The tower height is not changing. nor Is the site compound changing in size. The new cabinets are to be placed on the existing steel platform .. Site Plan Review Page 2 • Desalptlon of Site:: The site consIsts of approximately 21 aaes most of which is currently used as a solar panel field and cell tower site. A sniall portion of the parcel is deSignated as wetlands and floodplain. The Conservation Commission has issued a Negative Determination of Applicability for the proposed work.. Provision for Traffic Flow:. Unchanged. Parking: Unchanged. Drainage: Unchanged. Public Utilities: Unchanged. Landscap/ng/Saeenlng and Buffers: The following landscape note must be placed on the plan: "All plantIngs must be maintained and that portion of the public way abutting the parcel and including the treebelt.shall be maintained In a safe and attractive condition by the owner of the parcel." Slsn location: NA Exterior Ughtlng: Unchanged. Rendering or Elevations: O.K. Dumpster location: N.A. Other Comments or Concerns: The subject site is not to be used for equipment and/or vehicular storage or parking without site plan approval by the Plal'lning Board and compliance with Agawam's Zoning Ordinance. ..... "", ';';'" \'\, ;' j i i I i II I ,. . , • The information depicted on this map i8 for 'planning purposes only. It is not adequate for legal boundary dllfinlion. regulatory int8/llflll8tiOn. or parcel-level anaIyses_ J • " -~ ", ,:. \ \"0 j ,\1 i .; ___ ----.L--.. --~ t--_·_-- ! , i • ... I /1 I f " . I j i , , -) I r I ,- I ...• -~--~--.•. -... --.~------- I I Parcel k13 2 9 -Main Street 2151201510:26:52 AM 1:3228 1""269' To: CC: From: Date: Subjed: • • TOWN OF AGAWAM Department of Public Works Planning File 1000 Suffield Street • Agawam, MA 01001 Tel (413) 821 0600 • Fax (413) 821 0631 Christopher J. Golba • Superintendent MEMORANDUM Engineering Division February 3, 2015 SBA Tower Site -T -Mobile -369 Main Street -CC 315 Per your request, we have reviewed the plan entitled "SBA Agawam Monopole - T -Mobile -Wireless Telecommunication Facility, 369 Main Street, Agawam, MA; Prepared by: ProTerra Design Group, LLC. 4 Bay Road, Building A, Suite 200, Hadley, MA 01035; Scale: As-shown; Dated: 12/3012014." Engineering recommends approval of the plans. Engliieenng reserves the right to niakii additional coInIIients as new information is -submitted. If you have any questions please do not hesitate to contact this division. Sincerely, ~ (jf&~- Vladimir Caceres Civil Engineer I s:\cc1J IS -369 main st -optasite towers\l-mobile 2015\memo I.doc 'fI1;k/JCt. < Michelle C. Chase, P.E. Town Engineer • • Town of Agawam 36 Main Street Agawam, Massachusetts 01001-1837 February 9, 2015 SBA Towers II, LLC 33 Boston Post Road Marlborough, MA 01752 To Whom It May Concern: Tel; 413-786-0400 Fax 413-786-9927 At its duly called meeting held on February 5, 2015, the Agawam Planning Board voted to approve the Site Plan entitled "SBA Agawam Monopole - T -Mobile -Wireless Telecommunication Facility, 369 Main Street, Agawam, MA; prepared by Pro Terra Design Group, LLC" and dated 12/30/2014 , revised 2/4115. If you have any questions, please contact this office at 786-0400, extension 8738: Mark R. Paleologopoulos, Chairman AGAWAM PLANNING BOARD MRPIDSD:prk .. u, ()1 February 5, 2015 Town of Agawam Conservation Commission Ms. Pamela Kerr, Clerk 36 Main Street Agawam, MA 01001 Re: T-Moblle Antennas @ 369 Main Street, Agawam, MA 01001 T-Mobile Site /I 4SHM026A Dear Ms. Kerr: SBA Per request of the Board, attached please find an updated P-1 plan showing the new linear extent and approximate Base Flood Elevation of the FEMA 100-Year Flood Plain. The location of the equipment compound within the FEMA Flood Plain remains a designated protected resource area "Bordering land Subject to Flooding". That said, the change in the FEMA Mapping is not relevant. Additionally, the "old" FEMA Base Flood Elevation from 1978, depicted on Record CO for OEP File 87-0548, is elevation (approx.) 61.5 . The Record CO indicates the top of the TMO Platform at elevation 62.0. The "new" FEMA Base Flood Elevation from 7/16/13, depicted on the FEMA KMZ File, is elevation (approx.) 60.1, which is lower than the original designation. Using the original, accurate field topographic surveys submitted with OEP File 87-0548, the actual horizontal extent of the "new" 100-Year Flood Plain is smaller within the general vicinity of the Existing Equipment Compound. As a result of these changes, the SBA/T-Mobile installation is actually further from the current Flood line than had previously been assumed and our installation is even more acceptable, from a flooding point of view. Respectfully submitted, ~IIA.t~I.'r~~--------/ Properly Specialist SBA COMMUNICATION'S CORPORATION 33 Boston Post Road West Suite 320 Marlborough MA 01752 508.251 .0720 x 3804 + T 508.251 .1755 + F 203.446.7700 + C koellelier@sbasite.com • • AGAWAM OFFICE OF PLANNING & COMMUNITY DEVELOPMENT SITE PLAN REVI EW REVIEWER: D. Dachos DATE: February 4,2015 DATE RECEIVED: January 12,2015 DISTRIBUTION DATE: January 13, 2015 PLANNING BOARD MEETING DATE: February 5, 2015 APPLICANT IN FORMATION 1. Name of Business: SBA Towers II, LLC Address: 369 Main Street. Agawam 2. Owner: SBA Towers II, LLC Address: 33 Boston Post Road. Marlborough, MA 01752 Telephone: 508-251-0720 3. Engineer: ProTerra Design Group, LLC Address: 4 Bay Road, Building A. Suite 200. Hadley, MA 01035 Telephone: 413-320-4918 Fax: PLAN REVIEW Scale: 1" = 100' Date: December 30, 2014 Title Block (Street Address, Applicant's Name. Address. Scale. Name of Preparer of Plan): O.K. Description of Project: T-Mobile wishes to upgrade its equipment on the tower and in the premises. The tower height is not changing, nor is the site compound changing in size. The new cabinets are to be placed on the existing steel platform. Site Plan Review Page 2 • • Description of Site:: The site consists of approximately 21 acres most of which is currently used as a solar panel field and cell tower site. A small portion of the parcel is designated as wetlands and floodplain. The Conservation Commission has issued a Negative Determination of Applicability for the proposed work. Provision for Traffic Flow:. Unchanged. Parking: Unchanged. Drainage: Unchanged. Public Utilities: Unchanged. landscaping/Screening and Buffers: The following landscape note must be placed on the plan: "All plantings must be maintained and that portion of the public way abutting the parcel and including the treebelt shall be maintained in a safe and attractive condition by the owner of the parcel." Sign location: N.A. Exterior Ughtlng: Unchanged. Rendering or Elevations: O.K. Dumpster Location: N.A. Other Comments or Concerns: The subject site is not to be used for equipment and/or vehicular storage or parking without site plan approval by the Planning Board and compliance with Agawam's Zoning Ordinance. r / I /" • " I' # I; \ , -~ -, ,.. , " , " .".. /. , " .. -'" , " .\ , . , \. J ., , , " .' ~ :--' • .... ' . --• ..jj~,}- J ... • • " .. -. ,.,.,, '" 1...'-:.( _. '. ~ ':s '-I '-/Lc ' • -.J ., ...l • .. ...J;r ... ."A ., \ , " )' , • ,.J J I -, .rJ-" '"j' , " , !J" rtf ~'. o t ......\ -1 ~I J. J I ._ The information depicted on this map is for planning purposes only. It is not adequate " .. \ • I .. \ 'i ~ \ .\ for legal boundary definition, regulatory Parcel k13 2 9 . Main Street interpretation, or parcel·level analyses. 2/5/2015 10:26:52 AM , • M r . .. , , M ' - ® 1 :3228 1"=269' .. I . • ---1 I The information depicted on this map is for planning purposes only. It is not adequate for legal boundary definition, regulatory Parcel k13 2 9 -Main Street in~reretation, or parcel-level analyses. 2/5/201510:28:13 AM ® 1 :3228 1"=269' To: CC: From: Date: Subject: • • TOWN OF AGAWAM Department of Public Works -- Planning File 1000 Suffield Street • Agawam, MA 01001 Tel (413) 821 0600 • Fax (413) 821 0631 Christopher J. Golba • Superintendent MEMORANDUM Engineering Division February 3, 2015 SBA Tower Site-T-Mobile -369 Main Street-CC 315 Per your request, we have reviewed the plan entitled "SBA Agawam Monopole - T -Mobile -Wireless Telecommunication Facility, 369 Main Street, Agawam, MA; Prepared by: ProTerra Design Group, LLC. 4 Bay Road, Building A, Suite 200, Hadley, MA 01035; Scale: As-shown; Dated: 1213012014." Engineering recommends approval of the plans. Engineering reserves the right to make additional comments as new infonnation is submitted. If you have any questions please do not hesitate to contact this division. Sincerely, ~ (Jio~. Vladimir Caceres Civil Engineer I s:\cc\315 ·369 main Sl-optasite towers\l-ffiobile 201 S\memo Ldoc ruL4CL< Michelle C. Chase, P.E. Town Engineer • • Town of Agawam Interoffice Memorandum To: CC: From: Date: Subject: Eng. Dept., Police Dept., Fire Dept., ADA Committee Planning Board -y?Y 1/13/15 Site Plan -369 Main Street -SBA Towers -T-Mobile Please review and comment on the attached Site Plan for SBA Towers-T-Mobile. 369 Main Street prior to the Board's February 5th meeting. Please note: This item will appear on the January 27,2015 Team Meeting agenda. Thank you. DSD:prk FROM THE DESK OF ... YOUR NAME TITLE TOWN OF AGAWAM 36 MAIN ST AGAWAM. MA 01 001 Email address Here 413-786-0400 X Extension Fax: 413-786-9927 • • AGA W AM PLANNING BOARD Form D Application for Site Plan Approval Please complete the following form and return it and 10 copies of the Site Plan to: Agawam Building Department WOO Suffield Street Agawam, MA OIOOl 1. N arne of Business Stephen McGovern. Airosrnith Development, AS AGENT FOR SBA & T -Mobile Address, ___ ...!.'1OL\OLM!!!£em~·ml!!a~c~k,""S!!!trl!ie~et'o..'.2S.!!cU1~·te",,2£10!..,5'.::-B~, L!=:o,!:w~e~I""I,.£M~A~OC'cI2;85~2,-_______ _ Telephone: __ --.!26!.!.1.L7-:19C'c1,z:3-:.':!42.84~9<_ ____ Fax' _______________ _ 2. Name of App1icantiOwner_S~B~A,-T~o""w~e",,r~s~II!:2'..!cL~L~C,,--________________ _ Address, ____ .:C33~B~o~st~on~P~os~t~R~o~a~d,L!M~ar~lb~o~r~ou:'igh2.'2,~M~A~O~17!..:5:::.:'2'-_________ _ Telephone ___ .=.5~08::..--",25::cl,--O,,--7~2:::0 _____ Fax ______________ _ 3. Name of Engineer! Architect.".;P~r~o~T.:::e.:!rra.::::...!:D:::e~s::£ign~G:::.r~o:.':u~PL' =L=L:::C~ _____________ _ Address, ___ -24~B:::a~y~R~0~a~d'-', B~u~i~ld~in~g2..:A~, ~Su~i~te:.:2::.c0~0C!., ~H:::a~dl~ey!.c,c.:MA~:....'O~Ic'.'0=-35~ _______ _ Telephone: ___ .:..4:.:13::..-:::32::.:0::..-.:..49::..1:..::8~ ____ Fax. _______________ _ 4. Please give a brief description of the proposed project: Revised 2/! iQ i Project entails upgrades to existing telecommunications facility on behalf of existing carrier, T-Mobile. Not a new collocation; ground, compound is not changing; tower height is not changing. All upgrades will be performed on existing steeftEGi.~VeECne height. JI\N 12. 20\5 AGAWAM PLANN\NG BOARD -- GENERAL NOTES 1. THE PROJECT OWNER'S PCS FACIUTY IS AN UNMANNED PRIVATE ANO SECURED EOUIPMENT INSTAlLATION .. IT IS ONLY ACCESSED BY TRAINED TECHNICIANS F'OR PERIODIC ROVTINE MAINTENANCE AND THEREFORE DOES NOT REQUIRE ANY WATER OR SANITARY SEWER SER\I1CE. THE FACILI1Y IS NOT GOVERNED ay REGULATIONS REQUIRING PUBLIC ACCESS PER ADA REQUIREMENTS. WETLAND RESOURCE AREA WORK NOTES 1. THE SCOPE OF WORK DOES NOT INVOLVE DREDGING. FILLING OR ANY OTHER ACTIVITY THAT 15 CONSIDERED AN ALTERATION OF A WETlAND BUFFER ZONE OR BORDERING LAND SUBJECT TO FLOODING. REFERENCES PROPERTY LINE AND SITE CONDITIONS: ZONING SUMMARY TABLE ZONING DISTRICT: ASSESSOR'S 10: PROPOSED USE: IA -INDUSTRIAL A K1J 2. 9 WIRELESS COMMUNICATION FACILITY 2. THE PROJECT OWNER'S BASE TRANSMISSION STATION (BTS) CABINET IS A WEATHER RESISTANT, VANDAL RESISTANT STEEL CABINET CONTAINING RECTIFlERS, AMPUF'IERS. RADIOS, AND OTHER INTEGRATED ELECTRONIC CONTROL EQUIPMENT. THE STS IS ENVIRONMENTALLY CONTROllED BY A SELF-CONTAINED AC-POWERED HEATING AND COOLING SYSTEt.4 USING CfC-F'REE THERw.t. TRANSFER COMPOUNDS. TOWN OF AGAWAM GIS SYSTEM (OBTAJNED 12/30/2014); BASEMAP PREPARED BY MAGUIRE GROUP INC. FOR OPTASITE TOwERS LLC, LAST DATED 8/12/2008j PlAN PREPARED BY NORTHEAST SURVEY CONSULTANTS, DATED 07/27/2012. AN ACTUAL ON-THE-GROUND F'IELD SURVEY HAS NOT BEEN PERFORMED BY PROTERRA DESIGN GROUP, LlC. SETBACK DIMENSION REQUIRED PROVIDED (e) ANTENNAS -HEIGHT (AGl) 190' 181' 2. IN ACCORDANCE WITH THE PROVISIONS OF 310 CMR 10.02(2). THE SCOPE or WORK INVOLVES REPAIR AND MAINTENANCE (AND NOT AN ENLARGEMENT) Of AN EXISTING TE:lE:COMMUNICAnONS FACIUN AND THEREfORE All TEMPORARY CONSTRUCTION ACTIVITIES ANO All PERMANENT IMPROVEMENTS ARE EXEUPT FOR THE MASSACHUSETTS W£TLANOS ACT, FLOOOPVJN: FEUA FlRU MAP NUMBER 25013C040JE. (P) ANTENNAS -rRONT YARO 271.5' 1227': 3. THE DESIGN OF THE ANTENNA MOUNTING HARDWARE Will MEET THE ANSI/EIA/llA-222-G STANDARDS FOR STRUCTURAL STEEL ANTENNA SUPPORTING STRUCTURES AND STATE BUILDING CODE REQUIREMENTS, EFFECTIVE DATE .lJLY 16, 2013 (P) ANTENNAS -SIDE YARD (P) ANTENNAS -REAR YARD 271.5' 252'± 271.5' 369': 4. ONCE THE FACILITY BECOMES FUllY OPERATlONAL. NORMAL AND ROUTINE MAINTENANCE ev TOWER OWNER'S AND CARRIER'S TECHNICIANS WILL BE PERFORMED. THE ESTIMATED VEHICULAR TRAffiC GENERATED BY THESE VISITS IS PREDICTED TO BE LESS THAN THE TYPICAL TRAFF'lC GENERATED BY A SINGLE-FAMILY DWELLING. J. ALl PROPOSED TOWER-Bono~ RADIO ACCESS NETWORK EQUIPMENT IS LOCATED ABOVE THE WO-YEAR FLOOD PlAIN, ON AN EXISTING ELEVATED EQUIPMENT PLATFORM AT ELEVATION 62 (REFERENCE: DEP FILE 87-0548), APPROXIMATELY 1.9 FEET ABOvE THE FEMA 100-YEAR BASE FLOOD ELEVATION ESTABLISHED 7/'6/13. ZONE X -AREAS DETERM!NED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOOD. (e) CABINETS wITHIN FACllrTY FRONT YARD 40' 1215'± ZONE AE -BASE fLOOD AREAS DETERMINED (P) CABINETS WITHIN FACllrTY SIDE YARD 40' 2.34': lOO-YEAR FLOODlINE: FROM SURVEY PREPARED BY NORTHEAST SURVEY CONSULTANTS, DATED 07/27/2012. BASE FLOOD ELEVATION 60." BASED ON FEMA fIRM MAP NUMBER 25013C0403(, EffECTIVE DATE JJl Y 16, 2013 (p) WITHIN FACILITY -REAR YARO 40' 385'± 5. PERt.AANENT STANDBY EMERGENCY POWER WILL NOT BE UTILIZED BY PROJECT OWNERS. IF' NECESSJ>.RY, DURING AN EXTENDED POWER OUTAGE, A PORTABLE EMERGENCY GENERATOR Will BE USED TO PROVIDE TEMPORARY EMERGENCY BACKUP POWER. THERE IS NO ON-SITE BULK STORAGE OF FlAMMABLE OR COMBUSTIBLE FUELS FOR OPERATING AN EMERGENCY GENERATOR FOR THE PROJECT OWNER'S EQUIPMENT. 4. CONVENTIONAL CONSTRUCTION PRACTICES ANTICIPATED FOR THE INSTAlLATION OF THE PROPOSED TOWER-BOTTOM AND TOWER-TOP EQUIPMENT DOES NOT REQUIRE THE USE OF A DEDICATED HOISnNG CRANE. (P) CABINETS WITHIN FACILITY -HEIGHT AGL 40' 1S'± PARCEL L14-1-3 NOTE: SURVEYED i ~ ~ FlOOD TOea ___ J' .'';;. OVER FE~A FIRM GRAP GFV.PHIC ELEVATION ~. P _~UNE _ ARCEL t' l I3-1-3 """ -809 7' _ -,J..A L/ (E) GRA IiEl ORI\lEWA Y O!CTATE:S BASE F'LOOD ELEVATION LINE AND VALUE; ELEVATION IN FEET (FIR~ MAPPING) 'l-lf I -__ • ± --...::::::...-~ PARCEL L14-1-2 -H -.(1;-\-, ') ~-~~,,-:::::.-; ~ -:--C (E) 33' 'MOE RIGHT-OF-WAY 60 ~~;~~~Fci.L~'!~~&) 1 AHOSCAPf NOTE' ALL PLANTINGS MUST BE MAINTAINED AND THAT PORTION OF THE PUBLIC WAY ASunlNG THE PARCEL AND INCLUDING THE TREEBELT SHALL BE MAINTAINED IN A SAFE AND ATIRACTIVE CONDITION BY THE OWNER ~)~~ iP~CEt,: '~" I) ;>:?:U·\":':'.t. A.G.I1fi.M,U i>l.A~Uf~O iI4':~' -------------, ____ ~2;:9~2'.;±;... __ ..JO~...:5i~~ +I /h -~--~--",. '_ DRIVEWAY AND U/G . ~ /(..;:: ",/ ~~~----..,' ELECTRIC TO PUBLIC R.O.W. +I J.. '~ .... r",-»~~~~_ ,--6349' :~/./ JI/~/IRti' PARCEL a, (E) TREE LINE, TYP. -...... , ...... ~ ~'). '/ .... /v ~~'--:.. .:t __ . PARCEL g RECORD WETI.AND ~ , ...... , '0. r--',---~_r_-J..:-_--:r:~1 ~~~" L14-1-1· ~,.... -...... I ]' '---I' l12-4-21 ~ I I' (hL',,.-, UNE '00-'07 ,. 'J ' d \, ____ , '--_./ ...... -r=~ TOPOGRAPHICAL 100-~AR <-~ _ '-;, l _ ;--~ r----1 \, -, I", '."'1'" / I I I J FLOOD UNE (El£V=60.1) ~ -.L '-,-,-1 I .~ T ..LQ..C.!,!S ~ .... f-:J:.J~ -,.-1---:,-;",,; .. ,_I_,J, .... -; -,-~""; -;...: -! ~ J. J __ ; ~'~ \~ -"0... ~6.7·±. PARCEL K13 2 9 ~ // ,_,'-'+'L,--1_L -(E) ACCESS" UTIUTY EAso,ENT FOI.lO'MNG . ,1 .,: , •. ' " --'-,., __ 369, MAIN STREET ... _J 'jjIJ-' .. ~~ 1 , (E) ~~I~~Y .~~.D (E) ~/? U~~lTIES .1_ _;. ~'1~-. r '-~-')--= . ___ ._--=' PARCEL L14-1-11 ,,, '" ., N/F MUSHY S GOLF CENTER, LLC -II '. J: '-.. '. j-i.-!-. ..:1: ... ,,-. ... . ',-. (E) TELCO. EASEMENT FOllOWIN. G (E)~.. / __ ., N t,·~ ]""'J .. ..J ... 1-' LJ· .'" .. ' ... ...J~_J ... I . • OVERHEAD TELCO TO PUBL1C R.O.W .. ':~, ~ /. ' I 0. .A p --- RECORD INE1lAND 11 "-~ ,-'1'-1 .'·"J.-r.' .. '-1,L L U .r . ..J, -"-1"" "', "j' J_' . '.' L1NEB1-B9 (/·'-.l~_:,Jj:.I-' .. LI ' , .. .L.J.J....;.'"'~,-I_ j '""'-~_ I -I :':1 I !\- .... --1:,':;...: ' J 'j ..J..J ... _ ' -'<r .... I FlELD, T'YP. : .----~ ... ___ ----,,",' I::i. ,-'J ~' ~LJ __ -'--'_. ,.j I "":. ~ .. ,~, --I , ,..,. ---.; ---. -..'::.:::.::r~..J0-d-1:::~_I _'~" .i -!j~~.J~ ,~-l~ ,\1:'fE)" solAR PANEl 2 '.J I( d ~~---... ~~ ~-__ .L.-:.._..!...L !...!...'-L ____ ~.-\ __ ..L ...... _____ ~ _ ---~ 7687", '~~ = , _,_ .,,-l.L -1 " ~ f ?-"'"'..::... -~" 'WETLAND , ;.;.~ 398.5: ~~ =V;}.,)"", ---PARCEL K14-2-8 .," .... ' E ~ ..-f FLAG, TYP. .......... ... __ ... i L ,....... _J .... .A-.,~~, '-'\(', -".::.. Yt-J ... ,/"-",,,_,,? -, ~ -.~. _ PARCEL .... PARCEL '-o. ~. 0/ / ' ~ (E) AND (e) T-~oeILE EQUIP.~ENT ON / ~J \ \ PARKING AREA A -1 ELEVA TED FRAME AND (E) AND (P) PANEL - " ANTENNAS ON (E) 175· TAU MONOPOLE BASE FLOOO ELEVATION UNE ff " . t AND VALUE; ELEVATION IN E ~ - .,.. z SCALE: 1 "=200' (11 x17) l:§! ::::~I I I PARCEL K13-3-4 1 "=100' (22x34) I: !. • , ProTerra DESIGN GROUP, LLC 4 SAY ROAD, BUILDING A SUITE 200 HADlEY, I.4A 01035 PI'l:(41J)J2o-4918 [SBA.) SBA COMMUNICATIONS CORPORATION 33 BOSTON POST ROAD WEST, SUITE 320 t.4ARlBOROIJGH. I.4A 01752 PHONE: 508-251-0720 SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE 369 MAIN STREET, AGAWAM, MA 01001 ~ --Mobile- T-MOBILE NORTHEAST LLC ) 5 COMMERCE WAY, SUITE B NORTON, MA 02766 1 \ 2/04/16 FOR CONSTRUCTION JEB I TEJ I JMM o 112/30/14 FOR CONSTRUCTION JEB , TtJ , JIolIol No.1 1».1'£ REVISIONS i BY i CHI< IAPP'o SCAI£. '" SHOWN IDEStaNED 8'1'; JIM,4!ru ! DRAWN BY; et.J,I T-MOBILE COMPILED PLOT PLAN .,. ...... """ "" #13-062 p Jl ~ ~ GENERAL NOTES 1. THE PROJECT OWNER'S pes FACILITY IS AN UNMANNED PRIVATE AND SECURED EQUIPMENT INSTALLATION. IT IS ONLY ACCESSED BY TRAINED TECHNICIANS FOR PERIODIC ROUTINE MAINTENANCE AND THEREFORE DOES NOT REQUIRE ANY WATER OR SANITARY SEWER SERVICE. THE FACILITY .IS NOT GQVERN£D BY REGULATIONS REQUIRING PUBUC ACCESS PER ADA REQUIREMENTS. WETLAND RESOURCE AREA WORK NOTES REFERENCES PROPERTY LINE AND SITE CONDITIONS; 1--------------------------11 TOWN OF AGAWAM GIS SYSTEM (OBTAINEO 12/30/2014); 1. TH£ SCOPE OF WORK DOES NOT INVOLVE DREDGING, FILLING OR ANY OTHER ACTIVITY THAT IS CONSIDERED AN ALTERATION OF A WETLAND BUFFER ZONE OR BORDERING LAND SUBJECT TO FLOODING. ZONING SUMMARY TABLE ZONING DISTRICT: IA -INDUSTRIAL A ASSESSOR'S 10: K13 2 9 PROPOSED USE: WIRELESS COMMUNICATION FACILITY 2. THE PROJECT OWNER'S BASE TRANSMISSION STATION (8T5) CABINET IS A WEATHER RESISTANT, VANDAL RESISTANT STEEL CABINET CONTAINING RECTIFIERS, AMPLIFIERS, RADIOS, AND OTHER INTEGRATED ELECTRONIC CONTROL EQUIPMENT. THE BTS IS ENVIRONMENTALLY CONTROLLED BY A SELF-CONTAINED AC-POWERED HEATING AND COOL.ING SYSTEM USING CFG-FREE THERMAL TRANSFER COMPOUNDS. BASEMAP PREPARED BY MAGUIRE GROUP INC. FOR OPTASITE TOWERS LLC, LAST DATED 8/12/2008; PLAN PREPARED BY NORTHEAST SURVEY CONSULTANTS, DATED 07/27/2012. AN ACTUAL ON-THE -GROUND FIELD SURVEY HAS NOT BEEN PERFORMED BY PROTERRA D£SIGN GROUP, LLC, SETBACK DIMENSION REQUIRED PROVIDED 3. THE DESIGN OF THE ANTENNA MOUNTING HARDWARE WILL MEET THE ANSI/EIA/TIA-222-G STANDARDS FOR STRUCTURAL STEEL ANTENNA SUPPORTING STRUCTURES AND STATE BUILDING CODE REQUIREMENTS. 4. ONCE THE FACILITY BECOMES FULLY OPERATIONAL, NORMAL AND ROUTINE MAINTENANCE BY TOWER OWNER'S AND CARRIER'S TECHNICIANS WILL BE PERFORMED. THE ESTIMATED VEHICULAR TRAFFIC GENERATED BY THESE VISITS IS PREDICTED TO BE LESS THAN THE TYPICAL TRAFFIC GENERATED BY A SINGLE-FAMILY DWELLING. 2. IN ACCORDANCE WITH THE PROVISIONS OF 310 CMR 10.02(2), THE SCOPE OF WORK INVOLVES R£PAIR AND MAINTENANCE (AND NOT AN ENLARGEMENT) OF AN EXISTING TELECOMMUNICATIONS FACILITY AND THEREFORE ALL TEMPORARY CONSTRUCTION ACTIVITIES AND ALL PERMANENT IMPROVEMENTS ARE EXEMPT FOR THE MASSACHUSETTS WETLANDS ACT. .3, ALL PROPOSED TOWER-BOTTOM RADIO ACCESS NETWORK EQUIPMENT IS LOCATED ABOVE THE lOa-YEAR FLOOD PLAIN, ON AN EXISTING ELEVATED EQUIPMENT PLATFORM AT ELEVATION 62 (REFERENCE: DEP FILE 87-0548), APPROXIMATELY 1.9 FEET ABOVE THE FEMA tOO-YEAR BASE FLOOD ELEVATION ESTABLISHED 7/16/13. FLOODPLAIN: FEMA FIRM MAP NUMBER 25013C0403£, EFFECTIVE DATE JULY 16, 2013 ZONE X -AREAS DETERMINED TO BE OUTSIDE THE 0.2" ANNUAL CHANCE FLOOD. ZONE AE -BASE FLOOD AREAS DETERMINED CP) ANTENNAS -HEIGHT CAGL) (P) ANTENNAS -FRONT YARD (P) ANTENNAS -SIDE YARD (P) ANTENNAS -REAR YARD (P) CABINETS WITHIN FACILITY -FRONT YARD (p~ CABINETS WITHIN FACILITY SIDE YARD (p, I WIT"'N 'ACII ITY R>AR YARn fo\ .... Agl ... ,~C' IlIITUI~1 ". .. " .. lTV 190' 181' 271.5' 1227'± 271.5' 252'± 271,5' 369'± 40' 1215'± 40' 234'± 40' 38S'± lS'± 5. PERMANENT STANDBY EMERGENCY POWER WILL NOT BE UTILIZED BY PROJECT OWNERS. IF NECESSARY, DURING AN EXTENDED POWER OUTAGE, A PORTABLE EMERGENCY GENERATOR WILL BE USED TO PROVIDE TEMPORARY EMERGENCY BACKUP POWER. THERE IS NO ON-SITE BULK STORAGE OF FLAMMABLE OR COMBUSTIBLE FUELS FOR OPERATING AN EMERGENCY GENERATOR FOR THE PROJECT OWNER'S EQUIPMENT. 4. CONV£NTIONAL CONSTRUCTION PRACTICES ANTICIPATED FOR THE INSTALLATION OF THE PROPOSED TOWER-BOTTOM AND TOWER-TOP EQUIPMENT DOES NOT REQUIRE THE USE OF A DEDICATED HOISTING CRANE. u~IGHT (AGL) 40' 1 aO-YEAR FLOODlINE: FROM SURVEY PREPARED BY NORTHEAST SURVEY CONSULTANTS, DATED 07/27/2012. BASE FLOOD ELEVATION 60.1' BASED ON FEMA FIRM MAPI \' J ........... " •• ' ...... """. ,,...,.. I PARCEL L14-1-3 .+i PARCEL L13-1-3 NUMBER 25013C0403E, EFFECTIVE DATE JULY 16, 2013 NOTE: SURVEYED FLOOD TOPOGRAPHIC ELEVATION DICTATES I OVER FEMA FIRM GRAPHICAL FLOOD UNE ~: I BASE FLOOD ELEVATION LINE ~ AND VALUE; ELEVATION IN _ FEET (FIRM MAPPING) g -809,7'.t ___ (E) GRAVEL DRIVEWAY f' 60 ~ (E) ACCESS de ELECTRIC EASEMENT FOlLOWING (E) DRIVEWAY AND U/G ELECTRIC TO PUBLIC R.O.W. PARCEL L14-1-2 .; -::-)(-, __ ~_.: _ .. I. (E) .33' WIDE RIGHT-OF-WAY ----------r __ ~29~2::;'±;...._.,j°il ;;;. / A .. '.. --'-I PARCEL l14-1-1 PARCEL L14-1-11 .'" ...,rvn.- "" '", g N/F (E) TREE UNE, TYP. ~ RECORD WETLAND ~ .. LINE lA-lOA ... .... . ~ ." .LQQ.§" PARCEL K13 2 9 369 MAIN STREET MUSHY'S GOLF CENTER, LLC RECORD VriETLANO LINE Bl-B9 -'60 :,.. FEMA FIRM GRAPHICAL FLOOD ZONE LINE _'w---=:::~ --.J PARCEL K14-2-8 "0'" ~. 0/ g, .~. .", ~<),~ ,'/< / " -' ,/ 3o\~±' 1.~t't .,. .... 1..0'rA't.. ---",,~~" ,'" , '~o , · ,/ @«() 75'x75' FENCED COMPOUND CONTAINING , (E) AND (P) T -MOBILE EQUIPMENT ON / A -1 ELEVA TEO FRAME ANa (E) ANa (P) PANEL " ANTENNAS ON (E) 175' TALL MONOPOLE . /( .+1 1 I :efc £ / -.:;,~~:;.~ -. / ~9~ """" . :::::: .. ::: ......... - , '-......... RECORO WETLANO j. cc"-k· LINE 100-107 - -, /-...... -~ TOPOGRAPHICAL 100-YEAR / FLOOD LINE (ELEV=60.1') (E) ACCESS & UT1UTY EASEMENT FOLLO"WING II ." ,'/ --;~'<~'+I ;., v PARCEL l12-4-21 386,7'± ;.-...,~-~ .... lfo. , -Jj \. ~/" * <7" _ FIELO, TYP. I ' . PARCEL~. '. _"; .. ~-..... , .......... ~ .... , ~K13_2-6~"'''' PARCEL X --~,;<~ , .. 3985'± ' ~~~~:~~ (/~-\K,~'~3:-::":7~'0~"': .. ~~:::: ~ ~~ --. -- 768.7 :t WETLAND , FLAG, TYP. '--...... _ .... -') .-, "-''\ ~. ., f PARCEL K13-2-1 PARCEL K1J-2-8 , :" '-_/ 1=iARCEL K13-2-4 '". I'.~~' T f-CE) PAVEO PARKING AREA I : AND VALUE; ELEVATION IN \... FEET (FIRM MAPPING) t BASE FLOOD ELEVATION LINE .'-.......... (E) BUILOING, TYP. (E) BUILOING, TYP . /~ ... _---.... , &02 z,. fc2~'~~~~1~1~LOT PLAN ~ 1"=100' (22<34) "'" , ProTerra DESIGN GROUP, LLC 4 8A Y ROAD, BUILDING A SUITE 200 HADL.EY, MA 01035 Ph: (413)320-491B [SBA.) SBA COMMUNICATIONS CORPORATION 33 BOSTON POST ROAD WEST, SUITE 320 MARL.BOROUGH, MA 01752 PHONE: 508-251-0720 200 100 0 200 ~I I : SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE 369 MAIN STREET, AGAWAM, MA 01001 qJ --Mobile- T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 1 I 2/04/15 o 12/30/14 NO. DATE SCALE: FOR CONSlRVCTlON JE8 I TEJ I JIII'-1 FOR CONSlRUCTlON JEB I TEJ J Jtr.lM REVISIONS I BY I CHK I APP'O AS SHOWN 10ESIGNEO-BY; JMhI/TEJ JERAWN BY: BUI I ANPSCAPE NOTE: ALL PLANTINGS MUST BE MAINTAINED AND THAT PORTION OF THE PUBLIC WAY ABUTTING THE PARCEL AND INCLUDING THE TREEBELT SHALL BE MAINTAINED IN A SAFE AND ATTRACTIVE CONDITION BY THE OWNER OF THE PARCEL. ~~o~'~& '",,'II J'''/. ~-~ if JESSE M. '" j(~ MORENO ~ 1 8 ,\VIL Cil f T-MOBILE COMPILED PLOT PLAN JO!I Nu..BER .. on ,,,' #13-062 ~ P-1 ~1 SCOp e: OF WORK: SI TE ADDR ESS LATI TUD E: LONG ITUD E: JU RISDICTION: 70NING uURISDICT ION CURREN T US E: PROP OSED USE : DESIGN GU IDELINE: TOWER O'N!-J ER SBA SITE 10 : SBA ~MME PROJECT INFORMATION UNMANNED TELECOMIvI UNI CATI ONS FACILI TY T MOB ILE EQ UIPMENT MO DERN IZATION 369 MAIN STR EET AGAWAM, MA 01001 42" 05' 02.2" N (S BA RECO RD) 72' 36 ' 48.1" W (SBA RECORD) N.ATIONA L, STATE & LOCAL CODES OR ORD INANCES BASED ON II\lFORMATIO N PROVIDED BY T -MO BILE , THIS TELECOMf/UNICATIO NS EQUI D ~1ENT DEPLOYMENT IS AN ELIGI BL E FAC ILITY UNDER THE TAX RELI EF ACT OF 2012, 47 USC 1455(A), AND IS SUBJ ECT TO .AN EXPED ITED ELiG BL E FAC ILlTI =::S REQUES T/REVIEW AND ZON ING PRE -EMPTION FOR LOC AL DISCRETIONARY PERM iT S (VAR IANCE, SPECIAL F)E Rf;1IT, SITE PLAN REVI EW). TE LEcmAMUN ICATIONS FACILI TY TELECOMMUNICATI ONS FACILITY 5,A SBA TOWE RS II, LLC MA13546 AGAWAM -MUSHY'S CONFIGURATION SA SITE NAME:-" SBA AGAWAM MONOPOLE 369 ~,~A I N STREET AGAVvA~1 j MA 01001 S Tl 4S H ~~026A ~------------------------------------------------.,------.----~--------+----------------------------------------------------------------,------------------------------------------------------------------~ T-1 GN-1 P-1 A-1 A-2 A-3 A-4 A-5 S-1 S-2 G-1 DRAWING INDEX TITLE SHEET GENERAL NOTES COMPILED PLOT PLAN COMPOUND PLAN AND ELEVATION PLANS AND ANTENNA SCHEDULES EQUIPMENT PLANS DETAILS DETAILS EQUIPMENT PLANS EQUIPMENT PLANS GROUNDING, ONE-LINE DIAGRAM & DETAILS SIGNATURES REV o o o o o o o o o o o LOCUS MAP -,'- .",',. ';:." . ~-----------------------------.--------------------------------------~ CONSTRUCTION RF ENG INEERING 70N ING / SITE ACQ. ProTerra DESIGN GROUP, LLC 4 BAY ROAD, BUILDING A SU ITE 200 HADLEY. MA 01035 Ph. (41 3)320-49 1B DATE DATE DATE OPER JITIO NS TOW ER OW NER [SBA m] SBA COMMUNICATIONS CORPORATION 33 BOSTON POST ROAD WEST, SUITE 320 MARLBOROUGH, MA 01752 PHONE 508 -251 -0720 .. ,' DATE DATE " 1; . "t,:I,: , : ,.,., .. :: -:~ .'.' " ",.~ ~._., .. ;;':; 'i,:.~' , . SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE 369 MAIN STRE ET, p,GAWAM, MA 01001 -,;' "", ,; .. ,:...,' . . ,,-.. , . '.' " " ~. -Mobile- T·MOBILE NORTHEAST LLC 15 COMMERCE WAY, SU ITE B NOR TON, MA 0 2766 14 GENERAL NOTES 1. THI S DO CUM ENT IS THE CREATION , DESIGN, PROPERTY AND COPYR IGHTED WORK OF T -MOBILE' NORT HEAST , LLC . ANY DUPLICATION OR USE WI THOUT EXPR ESS WRIITEN CO NSENT IS STR ICTLY PRO HI BITED, DUP LI CATION AND USE BY GOV ERNMEN T AG ENC IE S FOR THE PURPOSES OF CONDUCTING THEIR LAWF ULLY AUT HOR IZED RE GULATORY AND ADM INISTRATIVE FUNC TI ONS IS SP ECIFICALLY ALLO WED. 7. THE FACILITY IS AN UNMANNED PRIVATE AND SECURED EQUIPMENT INSTAL LATION . IT IS ONLY .ACC ESSED BY TRAfNED TECHNICIANS FOR PERIODIC ROU TINE MAINTENANCE AND TH EREFOR E DOES NOT REQUIRE ANY WATER OR SAN ITARY SEWER SERVIC E. THE FACI LITY IS I\lOT GOVE Rr-JED BY REG ULAT IONS REQUIRING PUBLIC ACCESS PE R ADA REQU IREMENTS. 3. CONTRAC TOR SHA LL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND COND ITIONS ON THE JOB SI TE AND SH~LL IMMED IATE LY NOTIFY THE T -MOB ILE REPRESENTATIVE IN WR ITI NG OF DI SC REPANCIES BE FORE PROC EED ING WITH THE WORK OR BE RE SPONS IBLE FOR SAME. SPEC IAL STRUCTURA L NOTES : 1 TOW ER OW NE R SHALL PROVI DE GLOBAL ST RUCTURAL STAB ILITY ANA LYS IS OF EXI STI NG ANT ENNA SU PPORT STRUCTURE. GEN ERAL CON TRACTOR SCOP E OF WORK SHALL ' INCL UDE ALL REQ UI RED STRUC TU RA L MO DI FICATIONS, RE-BU ND U NG OF COAXIAL CAB LES OR OTHER SPEC IAL MOD IFICATIONS AS OU TLI NED THE RE IN. 2. STRUCTURAL DES IG NS AND DETAILS FOR ANT ENN A MOUNTS CO MPLE TED BY PROTE RR A DESIGN GROUP, LLC. ON BEHALF OF T -MOBILE AR E INC LU SIVE OF TH E ENTIRE AN TENNA SU PPORT STRUCTURE (GLOBAL STRU CTU RA L STABILITY AN ALYS IS BY OT HERS), EXISTING TOWER PLATFORM, EXISTING AN TE NNA MOUN TS AND ALL OTH ER ASPECTS OF THE STRUCTUR E THAT WILL SU PPO RT THE T -MOBIL E MOD ERNIZ ATION EQU IPMENT DEPLOYM ENT AS DEPICTED HEREIN. DIG SAF E SYSTE M ( M A, ME, N H , R I , VT) : 1 -888 -344 -7233 Cf\L L BE FORE YOU DIG (C T): 1-800-922 -44 55 UNDERGROUND SERVICE ALERT T-MOBILE TI TLE SHEET FOR CONSTRUCTION JEB TEJ JMM ~~--~------------R~~ISI-ON-S--------T-·-~BY~CH~K~~~~~~--------~~~--------~ #13-062 T-1 0 SCALE: AS SHOWN DESIGNED BY: JMM/TEJ DRAWN BY: BLM JAN 12 2015 AGAWAM PLANNING BOARD GENERAL NOTES 1. THE COI'JT'?ACTC? SHAll GIVE All NOTICES /\ND COMPLY WITH N .. l l.AWS, ORDI~"I'\NCES, RULES, REGUl/1i IONS I\ND _AWFUL OflDERS OF I'INY PUBLIC A.UTHORITY. MUNICIPAL Ar"D UTILITY COMPAI~Y SPECIFICATIONS, .AND LOCI\I_ I\ND STATE JURISDICTIONAL CC=:ES BE.ARING or,1 THF PlRCORMAI~CE OF nl[ WORI<. THE WORK PERFOR\~ED ON I HE PROJECT Ar"D THE IvAERIAlS 1'"SlAUED SHAU BF IN SIRIC' ACCORDANCE WITH A._l APPUC,I'\BlE CODES, REGUlAIIONS, AND ORDINA~ICES. 2. -HE ARCHITECT/ENGINEER IIAVE IVADE EVERY EFFORT TO SET =-ORTH I~I THE CONSTRUCTIO'" .AND CONTRACT JOCUMENTS THE COMPlEE SCOPE OF WCRK. THE CONTRACTOR B OOII,IG -HE JOG:S N[VERTHElESS CAUTIONEC THAT MII'IOR OMISSIONS OR ERRORS IN THE "';R.AWII~GS N"D OR SPECIlICATIONS SH.I'\ll NOT EXCUSE SA.ID COI~T?ACTCJR FROM COMPlETII~G THF PROJECT .ANO MPROVEMENTS IN ACCORO.ANCE WITH THF IfHENT OF THESE DOCUMENTS. 3. 'HE CONTRACTOR OR BIDDER SHAll BEAR THE R[SPONSIBILITY OF NOTIFYING (IN WRITING) THE LESEE/LiCENSEE REPRESENTATIVE OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO THE SUBMISSIO~ OF CONTRACTCR'S PROPOSAL OR PERFORMANCE OF WORK. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL coRICF THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED IN WRITING OTHERWISE. 4. THE SCOPE OF WORK SHALL INCLUDE FURNISHING All ~AATERIAlS, EQUIPME\lT, LABOR AND All OTHER M.ATERIAlS AND lABOR DEDAED NECESSARY TO COMPLETE THE WORK/PRO,JFCT AS DESCRIBED HEREIN. 5. I'""'l CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO THE SUBMISSION OF BIDS OR PERFORMI~IG WORK TO FAMILIARIZE H MSElF WITH THE FI::lD CONDITIONS AND TO VERI=-'( THAT WE PROJECT CAN BE CONSTRUCTED IN ACCORDA.NCE WITH THE CONTRACT DOCUMENTS. 6. -H:: CONTRACTOR SHA.ll OBTAIN .I'\UTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO SlllRTING WORK O~I ANV ITE~I NOT CLEARLY DEFINED BY THE CONSTRUCTION DR/\WINGS / CONTRACI DOC:UMENTS. 7. THE CONTRACTOR SHAU INSTALL All EQUIP~~ENT AND ~~ATERIAlS .ACCORDING TO THE MANUFACURER'S / VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WH::RE lOC.Al CODES OR ORDINANCES TAKE PRECEDENCE. 8. TH:: CO\ITRACTOR SHALL PROVIDE A FUll SET OF CONSTRUCTION DOCUMENTS AT THE SITE UPDATED WITH THE lATEST REVISIONS AND ADDENDUMS OR ClARIFICA-IONS AVAilABLE FOR 'HE USE BY All PERSONNEL INVOLVED WITH THE PROJECT. 9, THe: CONTRA.CTOR SHAll SUPERVIS[ AND DIRECT THE PROJECT DESCRIBEC HEREIN. THE CONTRACTOR SHAll BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION ,VlEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND lOR COORDINATING All PORTIONS OF THE WORK UNDER THE CONTRACT. 10, THE CONTRACTOR SHAll DE RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION CONTROL SURVEYS. ESTABLISHING AND MAINTAINI"IG .ALl LINES AND GRADES REQUIRED TO CONSTRUCT All MPROVEMENTS AS SHOWN HEREIN. 11. TH~ CON rRAC lOR SHAll BE RtSPONSI8lE ;:COR OBTA.!NII~G ,\ll PERMITS AND INSPlCTIONS WHICH MAY BE REQUIRED FOR THE WORK DY THE ARCHITECT/ENGINEER, THE 57 ATE, COUNTY OR lOCAL GOVERNMENT AUTHORITY. 1 L. rHE CONTRACTOR SHALL M/\'<E NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVE MEWS, EASEMENTS, PAVINC, CURSING; ETC QW~!.Ng CQ:'1;)mUCT!Q.N UPQ,N g9MPloET!QN OF WORK, I~E CO" I R!\C [DR SHAH RlPAIR AJN DAMACE THAT IviAY H.AVF OCCURRErJ r;UE TO cmlSTRUCTION ON OR ABOUT THE PROPERTY. 1.3. THE CONTRA.CTOR SH.All KEEP THE GENER.Al WORI< AREA CLEAN AND HAZ.ARD FRll DURI\lG CONSTRUCTION AND DISPOSE OF All DIRT, DEBRIS, RUBBISH AND RE~10VE EQUIPME\iT NOT SPECIFIED AS REMAINING ON THE PROPERTY. PREMISES SHAll OlE lEFT IN ClE.AN CONDITION AND FREE FRO~~ "JAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 14 THE CO~ITRACTOR SHAll COMPLY WI-H All OSHA REQUIRE~~EWS AS THEY AcoDLY TO THIS PROJECT. '15. THE CONnACTClR SHAI I NO-IFY THE lESEE/LICENSEE REPRESENTATIVl WHFRF 1\ CO~IFLICT OCCURS ON ANY OF THE CO\iTRACT DOCUMbN! S THE CONTRACTOR IS ~IOT TO ORDER MATERIAL OR CONS'RUCT .ANY PORTION o=-T-E WORK THAT IS IN CCJN~!ICT U~ITI_ CONFLICT IS RESOLVED BY THE lESEE/LiCENSEE Re:PRESEWATIVE, 16. THE CONTRACTOR SHAll VER!Fv All DI~~Ef"SIONS, ELEVA-IONS, PROPERTY LINES, ETC. ON THE JOB, 17. ALL UND::RGROUND UTILlTv INFORMATION WA.S DETERMINED FROM SURFACE I~IVESTIGATIOI~S AND EXISTING PI ANS OF R=-CORn THF rC""lN' RM~ [(,he SHill I LorATe: ALL UNDERGROUND UTILITIES IN THE FI::lD PRIOR TO ANY SITE WORK. CAll THE FOLLOWING FOR All PRE-CONSTRUCTION NOTIFICATION 72-HOURS PRIOR TO ANY EXCAVATION ACTIVITY: DIG SAFE SYSTEM (MA, ME, I~H, RI, 'IT): l-tltltl-544-7233 CAll BEFORE YOU DIG (CT): 1-800-922-4455 18. 1'-E CONTRA.CTOR IS RESPONS!BlE FOR PROV!DING r'\ll NECESSARY CONSTRUCTION CONTROL SURVlYS AND M.AINTAINING AU ! INrS f\ND GRADES REQUIRED TO CO~STRUC' ALL IMPROVl~~lN I S SHOWN HEREIN. 19. ALL DIMENSIONS SHOWN THUS -ARE APPROXIMATE. THE CON1 RACTOR SHAU VERIFY ALL DI~1ENSIONS AND FIEV>\T!ONS WHICH EcFECT THE COWRAC7 0RS WORK. CON I R!\CTOR TO VERIFY All DIMENSIONS WITH PROJECT CJWNlR PRIOR TO CONSTRUCTION. 20. NORTH ARROW SHOWN ON PLANS ?EFERS TO APPROXIMATE TRUE NORTH. PRiOR TO THE START 01 CONSTRUCTION, ORDERING OR I.AG?!CATING OF A\;T.ENNA MOUNTS, CONTRACTOR SHAH CONSULT WITH PROJECT O\v~IFR'S RF lNCINEER AND FIELD VERIFY All ANTENNA Sf C I CR I OCA.TIONS AI~D ANTEN'J.I'\ AZIMUTHS. 71. THF COWRACTOR .AND OR HIS SUB CONTRACTOR SHALL Bl RlS"ONSIBlE FOR OBTAINING All PERMITS AND II\SPECTIONS WHICH ~~AY BE REQUIRED FOR THE WORK BY THE .ARCH'TECT/ENGINEER, THE SU\re", COUNTY OR LOCAL GOVERNMENT AUTHORITY. 22. ANTENNA INSTALLATION SHAll I:Jl CONDUCTED BY FIElD CREWS EXPERIENCED IN THE ASSFMBlv AND lRlC liON OF RADIO ANTENNAS, TRANSMISSION LINtS A.ND SUPPORT STRUCTURES. 23. COAXIAL CABLE CONNEC IORS AND TRANSMITTER EQUIPMENT SHAll BE PROVIDED BY THE PROJECT OWNER AND IS NOT INCLUDED I~I 1 HlSE CONSTRUCTION DOCUMENTS A SCHEDULE OF PROJlCT OWNER SUPPLIED MATERIALS IS i'lTTACHED TO THE BID DOCUMENTS (SEE EXHIBIT 3). All OTHER H.ARDWARE TO BE PROVIDED BY THE CONTRACTOR. CONNECT'ON HARDWARE SHAll BE STAINLESS STEEL. 24. WHEN "PAINT TO MATCH" IS SPECiFIED FOR ANTENNA Cm"CEAl_~1ENT, P/\INT PRODUCT FOR ANTENNA RADOME SHAll BE SHERWIN WilLIAMS COROTHANE II. SURFACE PRt::PARATION AND APPLICATION SHALL BE iN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND PROJECT OWNER'S GUIDELINE'S. 25. COORDINATION, lAYOUT, AND FURNISHING OF CONDUIT, CABLE AND ALL APPURTENANCES REQUiRED FOR PROPER INSTALLATION OF ELECTRICAL AND TELECOMMUNICATION SERVICE SHAll BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 26. All UTiliTY WORK SHAll BE IN ACCORDANCE WITH lOCAL UTiliTY ~:OMPANY REQUIREMENTS AND SPECIFICATIONS. 27. AU (E)P.CTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTllTIES WHERE Er"COUI\ TERED IN THE WORK, SHAll BE PROTECTED AT AU TIMES, I\ND WHERE REQUIRED FOR THE PROPeR EXECUTION OF THE WORK, SHAll BE RElOCATED AS DIRECTED BY ENGINEERS. lX I Rc MF CAlHiON SHOUI D Be US:::D BY THE CONTRACTOR WHEN lXCAVAIING OR PIER CRUING AROUND OR NcAR UTILITIES. CONTRACTOR SHAll PROVIDE SA=-ETY TRAINING FOR rHE WORKiNG CREW. 28 .. 1I_l (E)IN.A.CTIVE SEWER, WATER, GAS, [lECTRIC AND OTHER UTILITIES, WHICH INT[?FERE WITH T .. E EXECUTION OF THE WORK, SHAll BE REMOVED NcO/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED A.T POINTS WHICH Will NOT INTERFERE WI'H THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF UTIUTY COMPMU ENG NEERING. THE AREAS OF THE PROPERTY DISTURBED BY THE WORK AND f\IOT COV::RED BY THE EQUIP~AENT, DRIVEWAY OR 29. GRAVEL, SHAll BE GRADED TO .A UNIFORM SLOPE, FERTILIZED, SEEDED ,lIND COVERED WITH MUlC" UNLESS OTHERWISE NOTED. THE CONTRACTOR SHAll ESTABLISH AND ~,1AINTAIN SOil EROSIO\ AND S::DIMENTATION CONTROLS AT All TIMES .10. nlJRING CONSTRUCTION. PER FCC MANDATE. EI\HANCED EMERGENCY (E911) SERVICE IS REQUIRED TO MEET NATIONWIDE S'ANDARDS 31, FOR WIRELESS COMMUNICATIONS SYSTEMS, DROJECT OWNER'S IMPLEMENTATION REQUIRES DEPLOYMENT OF EQUIPMENT AND ANTENNAS GENERALLY DEPICTED 0\1 THIS PLAN, ATTACHED TO OR ~OUNTED IN CLOSE PROXIMITY TO THE BTS RADIO CABINETS. PROJECT OWNER RESERVES THE RIGHT TO M.AKE REASONABLE MODIFICATIONS TO E911 EQUIPMENT AND lOCATION AS TECHNOLOGY EVOLVES TO IvlEET REQUIRED SPECIFICATIONS, 32. APPLICABLE DUllDING CODES: SUBCONTRACTOR'S WORK SHAll COMPLY WITH till N-'HIICAf-l1 ~ NATIONAL, STATE, AND lOCAL CODES AS AJOPTED BY THE lOCAL AUTHORITY HAVI~IG JURISDICTION (AHJ) FOR THE lOCATION. THl EDITION OF THE .AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. BUilDING CODE: M.I'\SSACHLISETTS STATE BUlllllNG CODE 780 CMR -8TH EDITION AJ"D AMEr"D~1E~HS ELECTRICAL CODE: I'IEC 2014 AND A\AENDIVHHS SUBCCNTRhCTOR'S WORK SHAll COMPLY WITH THE lATES7 lLllllON OF THE FOUOWIN(; STANDARDS: AMERICAN CONCRETE INSTITUTE CAC) 318: BUilDING CODE REQUIREMEI~TS !""OR STRUCTURAL CONCREE: AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL OF STEEL COI'-!STRUCTION, ASD, NINTH EDITION: TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 7n-G, STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: REFER TO FI .. ECTRICAl DRAWINGS FOR SPECIFIC E FCTR I CAl .. STANDARDS. FOR ANY CONf'LIC IS BETWEEN SECTIONS O~ LISTED CODFS AND STANDARDS RlGARDING MATERIAL, MFTHODS OF CONSTRUCTION, OR OTHER REQUIRDAc NTS, THl MOS I RESTRICTIVE Rr()UIREMFNT SHAll GOVlRN. WHERE THERE IS CONFliCT B;:CTWllN A GENERAL REOUIRFMENT AND A SPECIFIC RWUIRl~~t::NT, THE SPECIFIC RE()UIRDAEN I SHAll GOVERN. ELECTRICAL AND GROUNDING NOTES 1. ALL ELECTRICAL WORK SH,I'\ll CmWORM TO THE REQUIREMENTS OF THE I~ATIONAL ElECTR C.Al CODE (NEC) AS WEll AS .APPLICABlE STATE AND lOCA.~ CODES, 2. ALL ELECTRICAL ITEMS SHA_l Be: U.l. APPROVED OR LISTED AND PROCURED PER SPECIFICATION REQUIRlMlNI S 3. THE E'_ECTRIC,Al WORK INCluDES All lABOR AND ~~ATERIAL DESCRiBED BY DRAW NGS AND SPEC!FICATION INCLUDING iNCIDENTAL WOR'< TO PROVIDl COMPI ETF OPERATING AND .APPROVED ElECTR CAL SYSTlM. 4. GENERAL CONTRACTOR SHAll PAY FElS FOR HERMITS, /\ND IS RESPO~SIBlE cOR 081/\INING SAID PERMITS AND COORD NATION OF INSPECTIONS. " e:Le:CTRICAL Ar,ID TELCO INIRI~IC OUTSIDe: A 8UILDI~IC AND EXPOSED TO WEATHER SHAll BE IN WATER TIGIIT GALVANIZED RIGID STEEL CONDUITS OR SCHEDULE 80 PVC (AS PERMITTED BY CODE) AND WHERE REQUIRED IN LIQUID TIGHT FLEXIBLE METAL OR NONMETALLIC CONDUITS. 6. BURIED CONDUIT SHAll BE SCHEDULE 40 PVC. 7. '::lECTRICAL WIRING SHAll BE CO=>PER WITH TYPE XIIHW. THWN, OR THHN/THWN INSULATION. R. RLJ~I FI FCTRICAI CONDlJI' OR CABLE BETWEEN ELECTRICAL UTILITY DEMARCATION PO NT AND PROJECT OWNER CEll SITE PPC AS INDiCATED ON THIS DRAWING. PROVIDE FUll lENGTH PUll ROPE. COCRDINATE INSIAll/\1I0N WITH UTILITY COM,PANY, 9. RUN TELCO CONDUIT OR CABLE BETWEEN TElEC'HONE UTILITY DEMARCATION POiNT AND PROJECT OWNER CELL SITE TELCO CABINET AND BTS CABINET AS INDICATED ON TillS DRAWING. PROVIDE FUll lENGTH PU!_l ROPE AND GREENLEE CONDUIT MEASURING TAPE IN EACH INSTALLED TELCO CONDUIT. 10. WHERE CONDUIT BETWEEN BTS AND "JROJECT OWNER CEll SITE PPC AND BETWEEN BTS AND PROJECT OWNER CEll SIT[ TELCO SERVIC[ CABINET ARE UNDERGROUND USE PVC, SCHEDULE 40 CONDUIT, ABOVE TH::: GROUND PORTION OF THESE CONDUITS Sf-All BE PVC COI~DUIT, 11, ALL EQUIPMENT lOCATED OUTSIDE SHAll HAVE NEM.A 3R ENCLOSURE, 12. PPC SUPPLIED BY PROJECT OWNER, 13. GROUNDING SHAll COMPLY WITH NEC ART. 250. ADDITIO\iAllY, GROUNDING, BONDING AND LIGHTNING PRO-ECTION SHAll BE DONE IN ACCORDANCE WITH "T -MOB!lE BTS SITE GROUNDING STANDARDS". 14. GROUND COAXIAL CABLE SH E_DS MINIMUM AT BOTH ENDS USING MANUFACTURERS COAX CABLE GROUNDING KITS SUPPLIED BY PROJECT OWNER. 15, USE #6 COPPER STRANDED WIRE WITH GREEN COLOR INSULATION FOR ABOVE GRADE GROUNDING ('uNlESS OTHERWISE SPECIFIED) AND #2 SOLID TINNED BARE COPPER WIRF FOR BEI .. OW GRADE GROU~IDI~"G !IS INDICATED ON THE DRAWING. 16. 1\1 I GROUND CONNEClm"S TO BE BURNLlY HYGROUND COMPRESSlm~ TYPE CONNECTORS OR CADWElD EXOTHFRMIC WElD. DO NOT .AllOW BARE COPPER WIR=-TO BF IN CONTACT WITH GALVANIZED STEEL. 17. ROUTE GROUNDING CONDUCTORS Alm~G THE SHORTEST AND STRAIGHTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. GROUNDING lEADS SHOULD ~IEVER BE BEI~T AT RIGHT ANGLE. ALWAYS MA.'<F AT I FAST 12" RADIUS BENDS. #6 WIRE CAN BE BENT AT 6" RADIUS WHEN NECESSARY. 8m"D AblY ME:TAL Of),JE:CTS WITe-III" 0 FLcT OF Pr;:OJCCT OWNER EQUIPMENT OR CABINET TO MASTER GROUND BAR OR GROUNDING RiNG. 18. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO HOLE COMPRESSION TYPE COPPER lUGS. APPI .. Y OXIDE INHIBITING COMPOUND TO All lOCATIONS. 19. BOND .ANTENNA MOUNTING BRACKETS, COAXIA.l CABLE GROUND KITS, AND AlNA TO EGB PLACED NEAR THE ANTENNA lOCATION, 20, APPLY OXIDE INHIBITING COMPOUND TO All COMPRESSION TYPE GROUND CONNECTIONS. 21. CONTRACTOR SHALL PROVIDE AND INSTAll OMNI DIRECTIONAL ELECTRONIC MARKER SYSTEM (EMS) BAllS OVER EACH GROUND ROD AND BONDING POINT BETWEEN EXISTI\lG TOWER/ (E) MONOPOI E GROUNDING RING AND EQUIPMENT GROUNDING RING. 22. CON I R/,CTClR SHALL TEST COMPLETED GROUND SYSI FM AND RECORD RlSUUS cOR PROJECT ClOSE-OU DOCUMENTATION. 5 OHMS MAXIMUM RESISTANCE REQUIRED. 23.CONTRACTOR SHALL CONDUCT ANTENNA, COAX, AND lNA. RFTURN-lOSS AND DISTANCE-TO-FAULT MEASUREMENTS (SWEEP TESTS) AND RECORD RESULTS FOR PROJECT CLOSE OUT. ABBREVIATIONS AGL ABOVE GRADE I_EVEL G,C. GENERAL CONTRACTOR RF RADIO FREQUENCY AWG ,4MERICAI'J WIRE GAUGE MGB MASTER GROUND BUS BCW BARE COPPlR WIRE MIN MINIMUM TBD TO BE DETERMINED BTS BASE TRANSCEIVER STATION (P) PROPOSED/NEW TBR TO BE REMOVED (E) ~XIS 11 NG EG EQUIPMENT GROUND N,TS NOT TO SCALl REF REFERENCE TBRR TO B[ REMOVED AND REPLACED EGR EQUIPMENT GROUND RING REQ REQUIRED TYP TYPICAL = p~ ~erra SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE ~ --Mobile-T-MOBILE 1--+---+-----------.. --.. ---~.__t-I__----=---=--::..::..-=---=--=-==----__1 DESIGN GROUP, LLC 4 BAY ROAD, BUILDI'JG A SUI It :zoo HADLEY, MA 01035 Ph, (413)320-4918 SBA COMMUNICATIONS CORPORATION .1.1 ROSTON POST ROAD WEST, SUITE 320 MARLI:JCJROUGH, MA 01752 PHONE. 508-2!:J1 -anD 369 MAIN STREET, AGAWM~, I'A~ 01001 T-MOBILE NORTHEAST LLC 15 COMMFRCF WAY, SUITF Fl NOR-ON, MA 02766 o 12/30/14 ....... --t--~~-t-~- NO. DATE SCALE: GEI~::RAL NOTES FOR CONSTRUCTION JEB EoJ JMM REVISIONS BY CHK APP'IJ JOB NUMBER SHEET REV AS SHOWN I DESIGNED BY: JMM/TEJ I DRAWN BY: BLM #13-062 GN-1 o N EXISTING ANTENNA PLAN Sc'~L E : 1"=5' (11 x 17) 1 "=2.5 ' (22x34) (E) T-MOBILE PA NEL ANTENNAS TYP. OF (1) PE R SEC TOR, (3) TOTA L TO 3E RD jOVED (E) SAFETv CLI MB & CLIMB ING PEGS 1 A-2 2 .5 0 SECTOR SECTOR A: SEC TOR B: SECTOR C : SECTO R SECTOR A: SECTO R B: SECTO R C: ~ I~ ... ~! ~ _=-_ (E) GPS ON ICE BRIDGE (p) SPLIT LMU GPS PER RFDS (E) PP C---- (E) ICE BRIDGE (E) 3231 CABINET TO BE REMOVED E X I ST I I~G AN TE ~J NA SCH ED0 LE MAK E MODEL/i SIZE (IN CHES) KAT HREIN 800 -10504 6 .1 x2 .1xS4 KAT HRE IN 800 -1 0504 6 .1 x2 .7x54 L<:ATHREI N 300 -10504 6 .1 x 2.7x54 PROP OSED ANTENN A SC HEDULE MI'IKE MODELl ERICSSO f\1 AIR2 1 82A/84P ERICSSON AIR21 8 4A/82P ERICSSO N AI R2 1 82A/B4P ERICSSON AIR21 84A/B 2 P ERICSSON AIR21 B2A/B4P ER ICSSON AiR21 34A/82 P NOTE: 1. REFER TO FI NAL RF DATA SHEET FOR FINAL ANT EN NA SETIINGS. S IZE (INCHE S) -,2x7.8 x55.9 12x7.8x55.9 12x7.8x55.9 12x7.8 x55.9 12x7.8x55.9 12x7.8x55.9 (E) 10'x 1 6'~ / t..EA.sE AR EA ~ (P) 2" RIGID CONDUIT BETWEEN CABINETS @ RELOCATE (E) PPC & REFEED G-l 100AMP SERVICE (E) PLATFORM ACCESS LADD ER / / / / G ~}P) RBA72 CA81NET N / (P) T -ARM ASSEMBLY J(; TYP. OF (2) PER . / ,,- (P) AIR21 ANTENNA G~ SECTOR, (6 TOTAL) A-4 (SITEPRO 1 PART #UDS-NP) TO REPLACE (E) MOUNTS (E) MONOPO LE - (P) 2-1/2" SCH40 ---_~ (2 -7/8" 0.0.) 6FT. LONG ANTENNA SUPPORT PIPE TYP. (2) PER SECTOR (6 TOTAL) C'~ '-¢lC?p o· f (P) TMA, TYP. OF (1) PER SECTOR, (3 TOTAL) LOCATED ON ANTENNA PIPE MOUNT NO MOUNT SUBSTITUTION WITHOUT AUTHORIZATION FROM ENGINEER l (E) SAFETY Cl IMF3 & CLIMB ING PEGS / / N / PROPOSED ANTENNA PLAN SC ALE : 1"=5' (11x17) A-2 1 "=2.5 ' (2 2x34) 50 5 (p) 6201 CABINET WITHIN DELTA ENCLOSURE TO @ ACCOMMODATE 2G/3G & A-S (P) 4G MODERNIZATION EQUIPMENT L--I _~~I ~~ ____ I (E) (6) 1-5/8" COAX TO BE CAPPED & WRAPPED (P) (1) 1-5/8" HYBRID CABLE (FOLLOW (E) COAX CABLES TO ANTENNAS) (E) ICE BRIDG E (E) GPS ON ICE BRIDGE (P) SPLIT LMU GPS PER RFDS (E) ELEVATED 51 ~Eb FRf\M E IMAG E SO URCE : PROTERRA OS /2 9/14 EXISTING EQUIPMENT AREA @ PROPOSED EQUIPMENT AREA 4 SCALE: N.T.S. PrcTerra DESIGN GROUP, LLC 4 DAY ROAD, BUILDING A SU ITE 200 HADLE Y, MA 0 1035 Ph (413)320-4918 SBA SBA COMMUNICATIONS CORPORATION 33 BOSTON POST ROAD WES T, SUITE 320 MARLBOROUGH, MA 01752 PHON E: 508 251 -0720 3 A,-2 / SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE 369 MAIN STREET, AG Aw'I'-..M, MA 0 100', ~----------~---- SCA LE : 1"=5' (11 x17) A-2 1 "=2.5' (22x34) 5 2.5 o 5 F . ~ ---,._.+1 .. _EJ'------__ _ T-MOBILE 1----_ .... _...... ...... ~-----~ --Mobile-~----------------------~4-~~ T-MOBILE NORTHEAST LLC 15 COMMERC E WAY, SU I I E B NORTON , MA 02 766 o 12/30/14 NO. DATE SCALE: lOR CONSTRUCTION REVISIONS AS SHOWN DESIGNED BY: JM M/TEJ PLANS AND AN TEN NA SCH EDU LES JEB TEJ JMM BY CH K APP'O JOB NUMBER SHEET DRAWN BY: BLM #13-062 ! A-2 REV o ALL FRAME ALTERATIONS AND REINFORCEMENTS TO BE COMPLETED PRIOR TO INSTALLATION OF PROPOSED EQUIPMENT AND AFTER (E) STEEL HAS BEEN PLUMBED FIELD WELDING & 3RD PARTY INSPECTION REQUIRED JT=-~-----------------------L-=T~~ \ (E) BA R GR/\TING ~ (F) 5201 CABINET WITHIN DELTA ENCLOSURE TO ACCOMMODATE 2G/3G & (p) -~-------­(E) BTS CA BINET ---- TO BE REMOVED PrcTerra DESIGN GROUP, LLC 4 BAY ROAD, BU ilDING A SUITE 200 rADLEY, MA C1035 Ph:(113)320-1918 ------------- \. , i 4G MODERNIZATION EQUIPMENT (P) 2" RIGID CONDUIT---- BETWEEN CABINETS MAINTAIN 3' CLEAR-------- PER NEC (E ) IC E BRI DGE '~(E) ELEV/\TED STEEL :-RAME ~-1 ==--- RELOCATE (E) PPC ON (P) PPC MOUNTING BRACKETS, REPLUMB/WIRE ELECTRICAL AND TELCO FEED AS REQ'D (P) PPC MOUNTING BRACKET, TYP. OF 2, SECURED TO EXISTING FRAME (E) PLAT FORM ACC ESS LADDER EXISTING EQUIPMENT FRAME 1 SCALE: 1"=2' (1 1x17) 1"=1' (2 2 x3 4 ) SSA COMMUNICATIONS CORPORATION 3.3 BOSTON POST ROAD WEST, SUITE 320 ~~AR LBOROUG H , MA 01752 PHON E: 508-25' -0720 --------~----~ 2 1 PZzzt-~· ~=--=-=-~=---:J SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE 369 MAl N STREET, AGAWA "'-1, MA 0 1 001 tF · -Mobile· T-MOBILE NORTHEAST LLC 15 COMM ER CE WAY, SU ITE B NORTON , ~A 02766 " LO . o ---- (p) (1) 1-5/8" HYBRID CABLE (FOLLOW (E) COAX CABLES TO ANTENNAS) L,/-(E) (is) 1-h,/R" C:OAX TO BE CAPPED & WRAPPED --o o o o o o --~--"'-------(P) (1) 1-5/8" HYBRID LO o PROPOSED EQUIPMENT FRAME SCALE: 1 "=2' (1 1 x 17 ) 1"=1' (2 2x3 4) o 12/30/14 FOR ::;O NSTRUCTION JEB TEJ JMM CABLE (FOLLOW (E) COAX CABLES TO ANTENNAS) (E) IC E BRIDG E (E) GPS ON ICE BRIDGE (p) SPLIT LMU GPS PER RFDS (E) ELEVATED STEEL FRAM E (P) ADD DIAGONAL BRACING TO FRAME BELOW, TYP. OF ALL SIDES (P) REMOVE HANDRAIL TO ALLOW SPACE FOR RELOCATED PPC (P) ADD ADDITIONAL WELDED HANDRAIL POST IN KIND 2 A -3 T-MOBILE EQU IPM ENT PLANS NO. DATE REVISIONS BY CHK APP'O J0 8 NUMBeR SHEFT SCALE: /lS SHOWN DESIGNED BY, JMM/TEJ DRAWN BY: Bll.! #13-062 A-3 REV o (E) Al'HENNAS TYP. OF (1) PER SECTOR, C3) TOTAL TO BE REMOVED IMAGE SOURCE: PROTFRRA 05/79/1 4 <RI - (p) AIR21 ANTENNAS ON NEW ANTENNA MOUNT, TYP. OF (2) PER SECTOR, (6 TOTAL) ~~~ IMAGE SOURCE: PROT[RRA OS/29/14 EXISTING ANTENNA MOUNT, TYP. (~~\ --------~(----~I r--r ___ '\;. ~ \~~-, cr~~ (P) ANTENNA TO PiPE AIR CLA,~\~P KIT (KATHREIN #85010070) PROPOSED ANTENNA MOUNT, TYP. 2 SCALE: '~.' .S. ~y -(TYFJ. OF 2 ~)t.K KII) (P) 2-1/2" SCH40 \-------j SCALE: N.T.S. A-4 PrcTerra DESIGN GROUP, LLC L BAY ROAD, GUILDING A SUITE 200 HADLEY, W,, 01035 Fh: (4'13)320-4918 SBA SBA COMMUNICATIONS CORPORATION 33 BOSTON POST ROAD WeST, SUITE 320 MARLEOROUGH, MA 01752 PHO\JE: 508 251 -0720 -IX) I ~. < .--, . I . -. (2-7/8" 0.0.) MIN. ANTENNA SUPPORT PIPE TVP. . '--l ~-(P) T~1A MOUNTED TO PIPE TYP. (SEE RFDS FOR REO . CONFIGURATION) ! I , ,=,,,==.J ~ (P) JUMPERS, TYP. (P) AIR 21 ANTENNA MOUNTED TO PIPE TYP. (SEE RFDS FOR REO . CONFIGURATION) , ~ V . ~ )/ cA, " oj <=j 1:== . r' '-~~'l /; °3 I . !J. '" · ~~~I / ~ 0? " :':",,~~N\ I lj~ ..J 2" \~~ POWER, GROUND & -. -_. _. - - -.. -DATI', CADL[S TyP. AIR21 ANTENNA MOUNT TYP. /3 SCALE: N.TS SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE ,1\-4 ~ · -Mobile-T-MOBILE DETAILS T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE 8 NORTON, MA 02766 o 12/30/' 4 FOR COHSTRUCTION JE3 TEJ Jfm ---~T=~~~==~--------~~-------=~ NO. DATE REVISIONS BY CHK APP'LJ JOB NUMBER SHEET REV n u 369 MAIN STREET, ACAWAM, MA 01001 SCAl E AS SHOWN DESIGNFD BY JMM/TEJ DRAWN ElY: [JLM # 13-062 A - 4 Prc Terra DESIGN GROUP, LLC 4 BAY ROAD. BUILDING A SUITE 200 HADLEY, MA 01035 Ph: (413)320~49 1 8 ---36.1" J FROhlT VIEVV r SS OR A3 25 CALVo BO LTS PE R f,1ANU F.ACTIJ RER'S RE COMM EN D.ATIONS - RBS 6201 CABINET Jt Jt I I I I ~ 28.5" ~ SI DE VIEW IN DELTA ENCLOSURE 1 SC,LILE: NTS A-J -o N f'--- SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE SBA COMMUNICATIONS CORPORATION 33 BOSTON ["OST ROAD WEST. SUITE 320 MARLBOROUGH, MA 01752 PHor,E 508-251 -0720 369 MAIN STR EET, .!J..CAWM')', ~~A 01001 -30 .0" [ [ [ I I I I ~ ,I I, r ~ [ [ I [ I ~ FRO NT VIEW r SS OR A325 CALVo BO LTS PER fJlAN UFACTIJR ER'S RECOMMENDAT IONS 0 I I 00 0 0 0 0 0 0 0 , 39. 3" ----.~I I ro I 0 0 0 SIDE VIEW RBA 72 CABINET DETAIL 2 A-5 "'. ~ SCAlE; NT;;; tF --Mobile- T-MOBILE NORTHEAST LLC 15 COM MERCE WAY, SU ITE B NOR TON, MA 0 2766 T-MOBILE DETAILS 1---'-0 " 12/30/14 FOR CONSTRUCTIO N ~.E.B 2E_J ~~_M 1--::::::-:::-;:-:;::;:;::---,-____ --;::-;;::;::;-____ -,;:;;:;;1 ~N0::.t. --=:.DA~TE:...._~ _____ ...:.R:;.EV:.:::iS='O:.:::NS:...._ ___ __,-.L.:.:8Y....LC.:.::HK~AP.:.::r·.:::..D t';;'JO:;-:B :-NU--::MB:-::ER-=-t SHEET REV AS SHOWN DESIGNED BY: JMM/EJ I DRAWN BY: BLM #13-062 A-5 0 SCALE: (P) RELOCA-E (E) PPC. REFEED (E) 100Mv1P P":lC (.3) #1 AWG CU & (1) #5 AWG CL GROUND IN 1 1/2" CONDUIT. CONTR/\CTOR TO VIF IF CONDUIT SIZE A\JD F[EDING II;1EET \JEC CUT 1-\ WAY (E) HAN D RA I L ~=----~"~-~----"'Ii"',~ ~ TO ALLO\l{ CLEARANCE ~()R RELOCATED p":lC (P) .~D DAD D ITI 0 N,iI,I_ POST -----+1H-~~q__-__+____jH I\J f(IND (P) SECURE RELOCATED _~~~I~~r~~7~ PPC TO (P) PPC MOUNm~G BRACKETS PPC ~1CLNTING BRACKETS EQUIPMENT FRAME ISOMETRIC SC:i\LE;NQf~E (E) LADDER 1 c: ~ -1 2>- ALL FRAME ALTERATIONS AND REINFORCEMENTS TO BE COMPLETED PRIOR TO INSTALLATION OF PROPOSED EQUIPMENT AND AFTER (E) STEEL HAS BEEN PLUMBED FIELD WELDING & 3RD PARTY INSPECTION REQUIRED ~ (P) FIELD DRILL HOLES IN ~ BRA.CKET TO ~~ATCH PPC ~\WUNTING HOLES (P) r0 A-.325 G,iI,LV. BOLTS (P) r0 A-.325 GALV. BOLT TYP. AT [ACH END OF DIAGONAL BRACE TYP. OF 4 MIN. TO SECURE ~ PPC TO BRACKET @ (p) ppe MOLINTING (P) UX.3Xr' ,~NGLE DIAGONAL BR~CE TYP. OF 2 PER SIDE (P) FIELD WELDED T/\B TYP. S-2 BRACKET, TYP. OF 2 PPC MOUNTING SECTION - SCALE: 1 "=6" (11 x 17) 1 "=3" (22x.34) PrcTerra SBA DESIGN GROUP, LLC SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE tF · -Mobile- 4 B/\ Y ROA,), BUILDING A SUITE 200 SBA COMMUNICATIONS CORPORATION 33 BOSTON POST ROAD VEST, SUTE .320 MARLBOROUGH, MA 01752 PHONE: 508 251 -0720 o 12/30/14 FOR CONSTRUCTION NO. DATE REV!SIONS ~ o S-l RELOCATED DDC HANDRAil TO BE MOD'FIED WS FRAf..1E REAf..1 (P) r0 GALV A-.3?5 BOLT TYP. OF .3 PER BRACKET ~ (E) HSS POST BELO\N T-MOBILE ------+=-+-==-:--t-::-::-:-I JEB TEJ JMM EQUIPMENT PLANS 3Y CHK '>PP'D ,JOR NliMBER SHH::r HJ>DLEY, MA C1035 Ph: (413)3:2C-4918 .369 f..1A.IN STREET, .AGAWAM, f..!'A 01001 T-MOBILE NORTHEAST LLC 15 COMMERCE WAY, SUITE B NORTON, MA 02766 SCALE: ,>S SHOWN DESIGNED BY: JMM/TEJ DRAWN ElY BLM #13-062 S-1 REV o (Q) I1l 0 0 0 0000000 0 0000000 I _/' A /'- X )< )< ! I-" , [J [J 0 [J 0 ,r .g-I j I I I " -I-I~ i'-"'-\ --(P) EQLI P~~ E~n CABINETS A \ 1----4" +--J--I DETAIL A SCALE: 1 "=6" (' 1 x17) 1"=3" (22x34) (E) POST TOP PLATE TYP . ~ ~ (E) HSS POST TYP. 1 " TYP. 4 1 " 4 f-I ~o---------1 '-74" ------- 23 " ~ 1 " CONTRACTOR TO VERIFY IN FIELD ALL DIMENSIONS PRIOR TO FABRICATION ALL STRUCTURAL AND MISC. STEEL SHALL BE ASTM A36 UNLESS NOTED. ALL W& WT -SECTIONS SHALL BE ASTM A992 (50 KSI). STEEL PIPE SHALL BE ASTM A53 GRADE B (30 KSI). HSS SHAPES SHALL BE ASTM A500 GRADE B (42 KSI). ALL STEEL AND HARDWARE TO BE GALVANIZED. I--'tf 1T I \ 0 ~ ,. \ I I FIELD WELDING REQUIRED I T 4 4 P.) rlo"V ./' 0 ~ICXJ N I . n c .g- (E) CONe. PIER ~/ PrcTerra DESIGN GROUP, LLC 4 BAY ROAD. FlULDING A SlJl -E 200 I- HADL~Y, ~AA 010",S Ph:(413).520-4918 ~ I , "-~ '-~- '~ " ~" ~-------~~~ i"- 0 '-- (E) HSS FJOST TYP. ,f'\ / \ / ;~ -, I~ ~-I---~~ r----~ (P) ~"0 A-325 GALV. BOLT TYP. AT FACH END OF DIAGONAL BRACE (p) UX3X;J:" .~NGLE DIAGONAL BRACE TYP. or:-2 PER SIDE (P) FIELD WELDED TAB TYP. DIAGONAL BRACING TO BE ADDED TO ALL SIDES OF FRAME PRIOR TO INSTALLATION OF PROPOSED EQUIPMENT SBA SBA COMMUNICATIONS CORPORATION 33 BOSTON POS I ROAD WEST, SUTE 32D MARLBOROUGH. MA 017~2 SITE NUMBER: 4SHM026A SITE NAME: SBAAGAWAM MONOPOLE PHONE: 508-251-0720 ,-)69 MAI~J STREET, AGAWAM, MA 01001 . n ,r-', 0 ( -. ~ ~ TY FI '-li l L I __ LJ i-'1 r -" i: I Ul\ll ____ TO ---_. ., ........... MI Te' !!'\ H DP!' ! ! \..? '--.-___ --___ l' ~ 1" ________ -----1 r---/4 r-"-------1' -44"-- f'XY ~ ORMED FLAT BAR f' TIIICK PLAT[ 21 " -+ ____ 1 4 -- . r'---ICXJ N t . LOICXJ N PPC MOUNTING BRACKET SCALE: 1"=6" (11x17) 1 "=3" (22x34) tF --Mobile - M"0 HOLE TYP. ;f'X3" FORMED ;::-1 AT RAR f' THICK PLATE it0 HOLE TYP. S-:; o 12/30/14 FDR COfJSTRUCTION T-MOBILE EQUIP~AEr~T PLi\NS T-MOBILE NORTHEAST LLC 15 COMMERCE W,e:,Y, SUITE B I~ORTON, Mil 02766 NO. DATE _-----"'RE~VI-""SIO.)"'N~S ____ ,-----..L':'.BY~C:'..'.'HK~AP_'=__P'~D pJ;;:=OB~N::::::UM~BE:::::R -t-____ ----_-----;:::-:::.:SH~EE-T';:;-----------_ -_ -_ ---ffRE~-V SCALE: AS SHOWN DESIGNED BY JMM/TEJ DRAWN BY: BLM #' 3-062 S - 2 0