8734_SITE PLAN - 1408 MAIN STREET.pdfb73l{ --
St'-k Plo()--
ll{Q~ ~QI()
:5+r QJL+-
• •
Town of Agawam
36 Main Street Agawam, Massachusetts 01001-1837
February 7,2014
Stephen R. Cincotta
1408 Main Street
Agawam, MA 01001
Dear Mr. Cincotta:
Tel. 413-786-0400 Fax 413-786-9927
"" <= -
At its duly called meeting held on February 6, 2014, the Agawam Planning Board
approved the Site Plan entitled "Site Plan -Clinical Research Management -Additiorfi:
and Renovations -1408 Main Street, Agawam, MA" Prepared for: Clinical Research,:,?
Management, Inc., Prepared by: Architecture EI, Inc., Rev. dated: 2/612014 conditiomi
upon Board of Appeals approval and all professional staff comments being addressed:""
If you have any questions, please contact this office at 786-0400, extension 8738.
sm/~
Mark R. Paleologopoulos, Chairman
AGAWAM PLANNING BOARD
MRPIDSD:prk
Cc: ZBA
Insp. Services
Eng. Dept.
Town Clerk .
File
To:
CC:
From:
Date:
Subject:
• ~
TOWN OF AGAWAM
Department of Public Works
1000 Suffield Street • Agawam, MA 01001
Tel (413) 821 0600 • Fax (413) 821 0631
Christopher J. Golba • Superintendent
MEMORANDUM
Planning / Architecture EI, Inc.
File
Engineering Division
February 6th, 2014
Site Plan -Clinical Rc:scan:h Management -Addition and Renovations -1408 Main SL
Per your request, we have reviewed the Site Plan entitled "Site Plan -Clinical Research Management -
Addition and R.enovaJ:ions -1408 Main St, Agawam, MA"; Prepared for: Clinical Research Mal!agcmcnt, Inc,
1408 Main St, Aaawam., MA 01001. Prepared by: Architecture El, Inc., 264 North Main St, Suite 7, East
Longmeadow, MA, 01028; Scale: I" -20'; Rev. dated: 21612014, and we do not have any comments.
Sincerely,
Cole Filzpatriclc, E.I.T.
Civil Engineer I
s:\sp\S8S clinic 11 n.narch manqcmcnt 1 ~ miUn st'anemo 2 • pllJlfting board ~113.doc
To:
CC:
• • TOWN OF AGAWAM
Department of Public Works
1000 Suffield Street • Agawam, MA 01001
Tel (413) 811 0600 • Fax (413) 811 0631 -
Christopher J. Golba .SaperinteadeDt
Planning I An:hitecture El, Inc.
File
MEMORANDUM
From: Engineering Division
January 16,2014 Date:
Subject: Site Plan -Clinical Research Management -Addition and Renovations -1408 Main St.
Per your request, we have reviewed the Site Plan entitled "Site Plan -Clinical Research Management -
Addition and Renovations -1408 Main St, Agawam,MA"; Prepared for: Clinical Research Management, Inc,
1408 Main St, Agawam, MA 01001. Prepared by: Architecture El, Inc., 264 North Main St, Suite 7, East
Longmeadow, MA, 01028; Scale: 1"= 20'; Rev. dated: 12131(2013, and we have the followingcommeats:
I. Handicap parlcing spots must be 9' wide. Please revise the plan and the detail.
2. The Town of Agawam detail should be used for the Handicap parking spot signage.
3. Bends and restraint lengths should be shown on the plans for the 6" water line.
4. The Water Department prefers to install the 6" water service stub near the existing mailbox instead
of in the middle of the intersection of River Rd and Main St.
Engineering reserves the rigbt to make additional comments as new information is submitted. If you have any
questions please do not hesitate to contact this division.
Sincerely,
...3 ____ _ ~CL?
Town Eagineer
.~ ,pI51S oJinicoJ ........ h 111111",,,,,,,,,,' 1101 main ,'\momo , . ,~< plM.doc
• •
REFLECTORIZED (ENG. GRADE)
k VWHITE TEXT AND SYMBOL ON
\:). BLUE BACKGROUND (TYP.)
HANDICAPPED
PARKING _1Id_
":::: ... ""'!:' WH EN
--I ~ REQUIRED
VM>I V"
ACCESSIBLE~ _____ ALUMINUM SIGN (TYP.)
$300 FINE ~
D.P.W BREAKAWAY
~POST
PERMANENTLY
V INSTALLED INTO
1 FINISHED GROUND
SCALE: N. T.S.
HANDICAPPED
PARKING
SPEOAL PLA lE REQUIRED
UNAUlHMlZED \(H1ClES
MAY BE REMO\{\) AT
OWNER's EXPENSE
!illIE; MAXIMUM MOUNTING DISTANCE FROM HEAD OF STALL IS 10'
PLEASE SEE: MGl C. 40§21-22A. AAB 521 CMR 23.00, AGAWAM CODE §169-28
_!!'t: JGO
OI'ITt: Dltoa/lD
DWC. NO.: 1
","PROY£D II\': wee
TOWN Of AGAWAM
CONSTRUC~ON STANDARDS
SliT. _ SIfT. NO.
ACCESSIBLE PARKING SIGN A-'
9' 5' (8' FOR VAN) 9'
\--\--\-. I
~-I )I I 7 / 7 7 7· "'" )I I
Co
~
~ ~
!IC.IE! SEE AAB 521 eMR 2J.DD F"DR REQUIRED NUMBER OF" SPACES AND PROPORTION OF" VAN ACCESSIBLE SPACES.
~ BI': JGD II£VI5ION5
Do\re: 01/13/10 REV,
owe. NO.:
APPROVED 111': Nee
PRC.JECT
TOWN OF' AGAWAM
CONSTRUCTION STANDARDS
SHT. NAWE
ACCESSIBLE PARKING
SPACE
•
•
·SKT. NO.
A-2
chitecture!L • E n viro nment Life I nc . 264 North Moin 51., Suite 7. East longmeodow, MA 01028
Clinical Research Management February 6, 2014
-
Typical Vinyl Fence/Enclosure
www.ArchitectureEl.com • 413·525·9700. t • 413-525-9710, f • Admin@ArchitedureELcom
Page 1 of 1
• GE
Lighting Solutions
Evolve™ LED Post Top
Contemporary Conical (EPCC)
• imagination at work
•
RE Cr-;--~D
JAN 0 7 LU14
AGAWAM
PLANNING BOAAn
• •
Product Features
The new EvolveT• LEO Contemporary Conical Post Top offers energy efficiency and quality of light in a modern
European style. The advanced LED optical system provides improved horizontal and vertical uniformity, reduced glare
and improved lighting control. GE's unique optical ring technology effectively aims the light where you need it, while
eliminating the unsightly shadow circles commonly seen under other LED post top fixtures.
The Contemporary Conical post top can yield up to a 60-percent reduction in system energy compared with standard
HID systems, depending on applications. This reliable system operates well in cold temperatures and offers more than
11 years of service life to reduce maintenance frequency and expense, based on a 50,000 hour life and 12 hours of
operation per day. Containing no mercury or lead, this environmentally responsible product is RoHS compliant.
Applications
• Roadway, site, area, and general lighting utilizing
advanced LED optical system providing high
uniformity, excellent vertical illuminance, reduced
offsite visibility, and reduced on-site glare.
Housing
• Base and Body: die-cast aluminum housing.
• Top Upper Housing: one-piece spun aluminum.
• A contemporary decorative luminaire of truncated
cone design incorporates the heat sink directly into the
unit ensuring maximum heat transfer and long LED life.
• Meets 2G vibration standards per ANSI C136.32-2001.
For 3G rating contact factory.
LED & Optical Assembly
• Structured LED array for optimized raadway, walkway
and campus photometric distribution.
• Evolve light engine consisting of nested concentric
directional refiectors designed to optimize application
efficiency and minimize glare.
• Utilizes high brightness LEOs, 65 CRI at 4100K or
S600K typical.
• LM-79 tests and reports are performed in accordance
with IESNA standards.
Lumen Maintenance
• System rating is 50,000 hours at L85. Contact factory
for L rating ILumen Depreciation) beyond 50,000 hours.
Ratings
• UUcUL listed, suitable for wet locations.
• IP 65 rated optical enclosure per ANSI C136.25-2009.
• Temperature rated at -40· to 50·C.
Mounting
• Post top mounting O. D. 2 3/8-inch 160mm) or 3-inch
176mm) held in place with three hex heod set screws.
Finish
• Corrosion resistant polyester powder painted,
minimum 2.0 mil. thickness.
• Standard colors: Black, Grey and Dark Bronze.
• RAL & custom colors available.
Electrical
• 120-277 volt and 347-480 volt available.
• System power factor is >90% and THD <20%.
• Class "A" Sound rating.
• Integral surge protection non-dimming:
-For 120-277VAC per IEEE/ANSI C62.41.-1991,
4kV!2kA Location Category B21120 Events)
-For 347-480VAC per IEEE/ANSI C62.41.-1991.
6kV!3kA Lacation Category B31120 Events)
• Integral surge protection GE dimming:
-For 120-480VAC per IEEE/ANSI C62.41.2-2002,
6kV!3kA Location Category B 1120 Events)
• EMI: Title 47 CFR Part 15 Class A
• Photo Electric Sensors IPE) available for all voltages.
Warranty
• 5-year limited system warranty standard.
•
Ordering Number Logie
Contemporary Conical Post Top (EPCC)
EPee
P=Area
C = Contemporary
41 ,,277*
C=Conical 5 =480*
0=]47"
*Sperify single
voltage only if
fuse optiO'l is
selected
Photometries
p
EPee Type V -Symmetric Round (R5)
4,400 Lumens. 5600K IGE454569.ies)
~ ,
r' ,
:--/
" ""
fIE cootrot not
avoiklblefor
347 -480V Must be
a discrete voltage.
Grid Distance in Units of
Mountmg Height at 16'
Initiol Footcondle Values at Grode
Polar Trace Vertical Ofld Horizontal
PlGne through Horizontal Ang!e of
Maximum Candlepower
•
Cootod factory for
other colors,
~Contactfactory for oYOiIobility
EPee Type IV -Asymmetric Forward IA41
2,200 Lumens, 5600K IGE454570.iesl
v '" _, .1 ,
r'7 /. "I:::: ~
Grid Distance in Units of
Mounting He~ht ot 16'
Initiol Footcondle Values ot Grode
PolarTroce Vertical and Horizontal
Plane through Horizontal Angle 01
Ma)(imum Condlepower
EPee Type III -Asymmetric Wide IA3)
4,400 Lumens, 5600K IGE454571.iesl
, r-:<l , .\\
\ -r ,
I -)
h
I.: r-: ~
Grid Distance in Units of
Mounting Height ot 16'
Initial Footcandle Values at Grode
Polar Trace Vertical and Horizontal
Plane through Horizantal Angle of
Maximum Condlepower
•
Product Dimensions
,------=R f \,--=-; ---'-H-'---~~-
176in_ I r 1701 mmi
24.9 in.
1634 mmi
113 in_ -r--~:::iitfi=l 1566mmi T
10.2 in.
1260mm) \ , ,
lL6in.
(294 mm)
4.1 in.
[104 mml
29.9 in.
1760mmi
• Approximate Net Weight: 34~40 Ibs [16-18 kgsi
•
• Suggested Mounting Height: 8-16 It max [25~5 m)
• Effective Projected Area [EPA): L6 sq It max [0_15 sq m)
GE Lighting Solutions· 1-888-MY-GE-LED • wwwgelightingsolutions_com
1-388-6 ;.1-4 .<;-::;:'13
GE Lighting SOlutions,lLC is a subsidiary of the General Electric Company. Evolve and the GE brond ond loge oretmdemorks of the General Electric Company.
() 2012 GE lighting Solutions, LlC.lnformotion provided is subject to change without notice. All vaktes are design or typicoj values when measured under laboratory conditions.
OlP-2895IRev. 11/28/121
• • GE
Lighting Solutions
Evolve™ LED Area Light
Modular Fixture -Wall Pack & Egress (EWSW & EESW)
• imagination at work
• • Product Features
The GE Evolve™ LED Area Light alsa offers a wall pack that delivers the same autstanding performonce as the modular
area light solution. Using the same light engines as the "single module" area light, the wall pack affers identical
photometrics, which allows lighting designers to capitalize on the some features without compromise. In keeping with
a sleek design strateg~, this product offers a modern "wedge" look, balancing the need for photometric scalabilit~
with reliable workhorse performance. The wall pack provides 10 photometric combinations, available in two color
temperatures, to meet a wide range of application needs. The same wedge platform also offers an egress option to
compliment the famil~, and providing a complete and consistent look for all area lighting applications.
GE's exclusive optical ring design effectivel~ directs the light and produces superior verticol illuminance. Additionall~,
reduced energ~ consumption, combined with a long rated life that virtuall~ eliminates ongoing maintenance expenses,
enables the Evolve LED Wall and Egress to provide Significant operating cost benefits over the life of eoch fixture.
Applications
• Wall mounted, single module site, areo, and general
lighting utilizing advanced LED optical s~stem providing
high uniformit~, excellent vertical light distribution,
reduced offsite visibility, reduced on-site glare and
effective security light levels.
Housing
• Cast aluminum housing.
• Sleek architectural wedge design incorporates a
modular heat sink light engine directly inta the unit
ensuring maximum heat transfer and long LED life.
• Meets 2G vibration per ANSI C136.31-2010.
For 3G rating contact manufacturer.
LED & OpticClI Assembly
• Structured LED arrays for optimized area light
photometric distribution.
• Evolve modular light engine consisting of nested
concentric directional reflectors designed to optimize
application efficiency and minimize glare.
• Utilizes high brightness LEDs, 70 CRI at 4000K and
5700K typical.
• LM-79 tests and reports are performed in accordance
with IESNA standards.
Lumen Maintenance
• System rating is L85 at 50,000 haurs. Contact
manufacturer for Lxx rating (Lumen Depreciation)
beyond 50,000 hours.
Ratings
• ®I,® listed, suitable far wet locations.
• IP 65 rated optical per ANSI C136.25-2009.
• Temperature rated at -40· to 40·C 1-40· to 35·(
for 347-480V fixtures).
• Upward Light Output Ratio (ULOR); O.
Mounting
• Convenient swing out wall mount to "J" box with
inspection hole for IP 65.
Finish
• Corrosion resistant polyester powder painted,
minimum 2.0 mil. thickness.
• Standard colors: Black & Dark Bronze.
• RAL & custom colors available.
Electrical
• Wall Pack: 120-277 volt and 347-480 volt available.
• Egress: 120-277 volt universal electronic driver.
• System pawer factor is >90% and THO <20%.
• Class "A" audible sound rating.
• Integral surge protection non-dimming:
-For 120-277VAC per IEEE/ANSI C62.41.-1991,
4kV/2kA Location Category B21120 Events)
-For 347-480VAC per IEEE/ANSI C62.41.-1991,
6kV/3kA Location Category B3 (120 Events)
• EMI: Title 47 CFR Part IS Class A.
warranty
• 5-year limited system warranty standard.
• Ordering Number Logie
Wall Pack IEWSWI
EWSW
W=Wollpack
5 '" SmoH
W=Wedge
Egress (EESWI
E E SW
E =Egress
S '" SmoH
N
N
A 1
A 1
N
N
•
Contact
manufacturer for
other colors
*Future availability. Contact
morufocturer for details and timing.
OPTICAL TVPICAL INITIAL TYPICAL SYSTEM DISTRIBUTION BUG RATINGS
CODE TYPE LUMENS WATTAGE ORIENTATION 4000K S7aOK IES FILE NUMBER
4000K S700K 120-277V 347-480V AVAILABLE BUG BUG 4000K 5700K .. 1B!!l!I!III!III .... ___ •••• IlIIl1I1i11 ...
Photometries
EWSW Type IV -Asymmetric Forward IE41
7,400 Lumens, S700K IGE4S4407.iesl
,r-. ,
I" ;
Grid Distance In Ulllts of
Mounting Height at 12' Initial
Footcondle Values at Grade
Polar Trace Vertical and Horizontal
Plone through Hofizontoj Angle of
Maximum Condlepower
EWSW Type III -Asymmetric Wide IE31
7,400 Lumens, S700K IGE4S4434.iesl
.; lfi
Grid Distance in Units of
Mounting Height at 12' lnitiol
Footcondle Values ot Grode
PolarTmce Vertical and Hocizontol
Phmethrough Horizontal Angle of
Maximum Candlepcwer
• Product Dimensions
17.4 in.
1441mml
•
FRONT VIEW
.188 in. 15 mml DIA
for use with 4.000 in. 1102 mml
Octagon Box 14 placesl
.18B in. 15 mml DIA
for use with 3.250 in. 183 mml
Octagon Box 14 placesl
4.375 in.
1111mml
2.875 in.
173mm)
.188 in. (5 mml DIA
for use with Gem-Box
BACK VIEW
• Approximate Net Weight for Wall Pack: 29 Ibs 113 kgs)
• Approximate Net Weight for Egress: 241bs III kgs)
TOP VIEW
18.4 in.
1466mm)
11.6 in. I
1294 mml ----!
SIDE VIEW
GE lighting Solutions· 1-888-MY-GE-LED • www.gelightingsolutions.com
eRR-:=; C}_~ >S33
GE Ughting Solutions, LLC is 0 subsidiGllj of the Geoeral Electric Compony. Evolve and the GE brand and logo ore traderrooOOi of the General Electric Company.
Q 2012 GE Lighting Solutions, LlC Information provided is subject to challge without notice. AU values ore design ortypiC{]1 values when meosured under loborotDrY conditions
OlP-2894!Rev.11128/12)
DATE:
TO:
FROM:
RE:
•
Town of Agawam
Board of Appeals
36 Main Street
Agawam, MA 01001
MEMO
January 13,2014 /'
Planning Board V
Board of Appeals
Site Plans for: Steve Cincotta (Five-C Realty)
1408 Main Street
•
REASON: Steve R. Cincotta (S-C Realty), who is seeking a Special Permit in accordance with
Section 180-7, Paragraph B(2) of the Town of Agawam's Zoning Ordinances to allow for the
expansion of a business located at the premises identified as 1408 Main Street.
Attached please find 10 copies of the site plan for the above referenced property. These plans are
for your review and comments, and any recommendations you may have so we can consider
these recommendations and comments in our final decision. If you do not respond to this
Board within thirty-five (35) days of the above referenced date, we will assume that you
have no objections.
•
emorandum
To: Planning Board
CC: Chief Eric Gillis
From: Sergeant Donald Gallerani
Date: January 14,2014
•
Re: Site Plan -Clinical Research Management -1408 main Street
The site plan proposal for Clinical Research Management located at 1408 Main St.
it.o. add a 2,174 sf addition, make renovations to existing building, and improvements , );" '9.tn~parking and entrances for repair and accessibility compliance will have no
~pac1',2n pedestrian or motor vehicle safety.
iI6." ... "' •...•. ~... "'. ~·~'w' " ,,0~¥::':' :::~:~ ~:
~es~ctfull
/;1, r.;
1
•
AGAWAM OFFICE OF PLANNING & COMMUNITY DEVELOPMENT
SITE PLAN REVIEW
REVIEWER: D. Dachos DATE: January 13, 2014
DATE RECEIVED: January 7, 2014 DISTRIBUTION DATE: January 7, 2014
PLANNING BOARD MEETING DATE: January 16, 2014
APPLICANT INFORMATION
1. Name of Business: Clinical Research Management
Address: 1408 Main Street, Agawam, MA
2. Owner: Stephen R. Cincotta
Address: Same
Telephone: 413-821-0022 Fax: 413-821-0040
3. Engineer: Architecture EL -Principal: Kevin Shea
Address: 264 N. Main Street, E. Longmeadow, MA 01028
Telephone: 413-525-9700 Fax: 413-525-9710
PlAN REVIEW
Scale: 1"=20' Date: December 31,2013
Title Block (Street Address, Applicant's Name, Address, Scale, Name of Preparer of
Plan): O.K.
Description of Project: Proposed 2,174 square foot addition to an existing
bUSiness/professional office, renovations to existing building and improvements to
parking and entrances for accessibility compliance.
Site Plan Review
Page 2
• •
Description of Site: The proposed location of the addition is in lawn and parking lot
currently. No filing with the Conservation Commission is necessary.
Provision for Traffic Flow: Unchanged.
Parking: Using Agawam's Parking Guidelines, 16 parking spaces are recommended and
have been provided.
Drainage: See Engineering comments.
Public Utilities: See Engineering comments.
Landscaping/Screening and Buffers: Unchanged. The following landscape note must be
placed on the plan: "All plantings must be maintained and that portion of the public way
abutting the parcel and including the treebelt shall be maintained in a safe and attractive
condition by the owner of the parcel."
Sign Location: Unchanged.
Exterior Lighting: All lighting must be recessed and shielded.
Rendering or Elevations: Colors to be provided.
Dumpster Location: Height of fence should be noted on the plan. Dumpster must also
be gated.
Other Comments or Concerns:
• •
TOWN OF AGAWAM, MASSACHUSETTS
FORM 0
Application for Site Plan Approval
Please complete the following form and return it and ten (10) copies of the Site Plan to:
Agawam Inspection Services
1000 Suffield Street
Agawam, MA 01001
January 07 20 14
1. Name of Business Clinical Research Management
Address 1408 Main Street
Phone # (413) 821-0022 Fax # (413) 821-0040 email
________________ ------:----:s~c:::.in::::co~tt~a~@~c::lin_'.::icalresearchmgt.com .---~
__ /2: Name of Applicant!Owner Stephen R. Cincotta (Five-C Realty) ) -'/ ---'-------~--------
Address 1408 Main Street
"'-' Z e;;, (/)
Phone# (413)821-0022 Fax# (413)821-0040 email ]> <;..:: ;:g scincotta@clinica~se@;hm@;com
~ I -c:>
3. Name of Engineer!Architect Architecture EL -Principal: Kevin Shea ~:: co :z
U UJ
fT1
Xl
Address 264 N. Main SI. East Longmeadow, MA 01028 L!'J <
(")
.D f"Tl
U)
Phone # (413) 525-9700 Fax # (413) 525-9710 email
4. Please give a brief description of the proposed project:
One Story, 2,174 SF addition to existing business! professional office; renovations to
the existing building to provide bathrooms & new staff break area; improvements
to the parking & entrances for repair and accessibility compliance.
• •
Town of Agawam
36 Main Street Agawam, Massachusetts 01001-1837
Tel. 413-786-0400 Fax 413-786-9927
MEMO
TO: Engineering Department, Police Department, Fire Department, ADA Committee
FROM: Planning Board y S. V
SUBJECT: Site Plan· Clinical Research Management· 1408 Main Street
DATE: January 7, 2014
Please review and comment on the attached Site Plan for an addition to Clinical Research
Management at 1408 Main Street prior to the Board's January 16th meeting.
Thank you.
DSD:prk
• •
TOWN OF AGAWAM, MASSACHUSETTS
FORMD
Application for Site Plan Approval
Please complete the following form and return it and ten (10) copies of the Site Plan to:
Agawam Inspection Services
1000 Suffield Street
Agawam, MA 01001
December 31 20...:1-",3_
1. Name of Business Clinical Research Management
Address 1408 Main Street
Phone # (413) 821-0022
'. .'
~., c . .",
~
,-. :
:z: en v
I , I
C")
--j
0 Fax# (413) 821-0040 email::
scincotta@clinicattllsea,rvhmgtcom U fq
:::1:.J
2. Name of Applicant/Owner -"'S",te"'p""h"'e"'n...!,R"' . ..,:C""i"'nc"'o""tt"'a'--_______ ·_:_· ~"''''',,' --;<""
.:::) ("'j
Address 1408 Main Street
o r"T1
U>
Phone # (413) 821-0022 Fax # (413) 821-0040 email
scincotta@clinicalresearchmg\.com
3. Name ofEngineer/Architect Architecture EL -Principal: Kevin Shea
Address 264 N. Main SI. East Longmeadow, MA 01028
Phone # (413) 525-9700 Fax # (413) 525-9710 email
4. Please give a brief description of the proposed project:
RECEIVED
JAN ()7 2014
AGAWAM
PLANNING BOARD
One Story, 2,174 SF addition to existing business/ professional office; renovations to
the existing building to provide bathrooms & new staff break area; improvements
to the parking & entrances for repair and accessibility compliance.
•
264 Norlh Moin Sr., Suire 7, Easf longmeoooll(, MA 01028
Letter of Transmittal
To: Mr. Erik Wight Date: 1/6/2014
Inspector of Buildings
1000 Suffield Street
Agawam, MA 01001
Re: 1408 Main Street, Clinical Research Management Job No. 2013-35
We are sending you: 0 Attached I Under separate cover via:
o Prints D Specifications D Shop Drawing D Samples
D Addenda D Requisition D Change Order 0 Other
Copies Date Description
12/31/13 Application for Site Plan Approval-Form D
3 12/31/13 Application for Special Permit
01/03/14 Check #1000 -$250 payable to Town of Agawam
3 06/04/03 Quitclaim Deed w/ Exhibits
19 12/31/13 Site Plan Drawing Package (1 set signed & sealed)
C1-Cl Civil Drawings
A2.1-A2.2 Building Elevations
7086SH01 -Site Survey
Site lighting fixture cut sheets
Please find attached site plans, building elevations, and application forms, as required for
the pending Site Plan Review and Special Permit Application
cc: File
Stephen Cincotta, Clinical Research Management
Chris Tait, P.E. Doucet & Associates
From: Kevin P Rothschild-Shea, AlA RECEiVED
J, .... n'7 ~'i4
1""\" V . -
AGAWAM
PL~,,~~Nir~G S('tJlD
www.ArchifedureELcom • 413·525·9700, t • 413-525-9710, f • Admin@ArcnitectoreEl.com
Page 1 of1
, ,
SITE INDEX
NO. DRAWING TITLE
C1 COVER SHEET
C2 LEGEND & GENERAL NOTES
C3 LAYOUT & MATERIALS PLAN
C4 GRADING & UTILITY PLAN
C5 PHOTOMETRIC PLAN
C6 DETAILS
Cl DETAILS
ADDITIONAL PLANS
NO. DRA WING TITLE
A2.1 PROPOSED BUILDING ELEVATIONS
A22 PROPOSED BUILDING ELEVATIONS
1 AS·BUILT PLAN OF LAND IN AGAWAM, MA
APPLICANT: CLINICAL RESEARCH MANAGEMENT, INC.
1408 MAIN STREET
AGAWAM, MA 01001 Ph. (413) 821·0022
ARCHITECT: ARCHITECTURE EL. INC.
264 NORTH MAIN STREET, SUITE 7
AGAWAM, MASSACHUSETTS
LATEST ISSUE
2/6/2014
2/6/2014
2/6/2014
216/2014
2/6/2014
2/6/2014
2/6/2014
LATEST ISSUE
1/29/2014
1/2912014
10/9/2013
LOCUS MAP
1" = 200'
ftA DOUCET It:~ & ASSOCIATES
Austin. Texas· Gonzales. Texas· Northampton. Massachusetts
www.doucetandassociates.com
UTILITY
ELECTRIC
WATER
SEWER
TELEPHONE
CABLE
NATURAL GAS
FIRE DEPARTMENT
BUILDING OFFICIAL
EAST LONGMEADOW, MA 01028 Ph. (413) 525·9700
UTILITY CONTACTS
UTILITYCO. CONTACT
WMECO THOMAS CAMPBELL
300 CADWELL DRIVE
SPRINGFIELD, MA 01104
AGAWAM DPW JOHN DECKER
1000 SUFFIELD STREET DEP. SUPERINTENDENT
AGAWAM. MA 01001
AGAWAM DPW
36 MAIN STREET
AGAWAM. MA 01001
VERIZON LINDA SHEDD
220 BROOKS STREET
WORCESTER. M A 01606
COMCAST DAN MILLIRON
1110 E. MOUNTAIN ROAD
WESTFIELD, MA 01085
COLUMBIA GAS OF MA
2025 ROOSEVELT AVE, PO BOX 2025
SPRINGFIELD. MA 01102
AGAWAM FIRE DEPARTMENT JAKE DUSHANE
800 MAIN STREET FIRE INSPECTOR
AGAWAM, MA 01001
AGAWAM INSPECTION SERVICES ERIK WIGHT
1000 SUFFIELD STREET INSPECTOR
AGAWAM, MA 01001
REVISIONS'
NO. IJESCRIPTION , DPW COI.4I14ENTS
TELEPHONE
PH. (8Tl) 659-6326
PH. (413) 821-0627
FAX (413) 821-0631
PH. (413) 786-0400
FAX (413) 786-9927
PH. (413) 454-3170
PH. (413) 562-9923
x73247
PH. (888) 639-4270
PH.(413) 786 0657
PH. (413) 821 0632
/
Scale<
RE'v1SION Designed by.
DATE DraM! by.
2/6/14 R_by.
Date<
1
Projeet No!
rJ)
Z o -~ > o z
u.J
~
~
Z o -I--o o «
N.T.5.
CTS
JBB
TJH '
Dec. 311 2013
SHEET
C1
OF 7
1355-001
EXISTING
----x----
---01---
10+00
----ELEV----
---ELE¥V~--
---w---
---5---
---T---
---D---
---E---
---G---
---OHW'----
o
=
08-80
D
CD
@
®
M wv
[><]
TBM
<rc -~c,_-~c--~
e •
LEGEND
PROPOSED
---x----
---!o---
10+00 I
---Il!ill't'-( --
----jl!ill'l'-( --
~
---W'---
---5---
---T---
-LOCUS PROPERTY LINE
-ABUTTER PROPERTY LINE
-CHAIN LINK FENCE
-STOCKADE FENCE
-BASELINE
-MAJOR CONTOUR (5 FEET)
-MINOR CONTOUR (1 FOOT)
-TREE LINE
-UNDERGROUND WA 1ER LINE
-UNDERGROUND SEWER LINE
-IINnf"Rr.fmIlNn 71'"1 f"P!./()Nf" UNF
-UNDERGROUND DRAIN LINE
---E -UNDERGROUND ELECTRIC LINE
---GAS -UNDERGROUND GAS LINE
---OHW -OVERHEAD WIRE
o -BOLLARD
-"--SIGN
= -DOUBLE SIGN
-IRON PIPE
D
cu..,
...,0
II1II -• • 0-
~
[
-PULL BOX
-UTILITY POLE
-BORING LOCA TION
-CA TCH BASIN
-DOUBLE CA TCH BASIN
-DRAIN MANHOLE
-SEWER MANHOLE
-HYDRANT
-WA TER VALVE
-PLUG/STUB
-LAMP POST
TBM -1EMPORARY BENCHMARK
... ---vc-~c_---.o -GUARDRAIL
-TREE (DECIDUOUS)
-TREE (CONIFEROUS)
-PARKING COUNT
-HANDICAP RAMP
-HANDICAP PARKING
-VAN-ACCESSIBLE HANDICAP PARKING
ABAN
ACR
ADJ
APPROX
BB
BC
BOS
BS
CC
CCB
CC&G
ELEV
EXIST
FDN
GC
GE
MAX
MCC
MIN
NIC
NI::i
PCC
PROP
REM
RET
REMOD
R&R
R&S
SGE
SKF
TOS
TS
TYP
VGC
ACCCMP
CAP
C&C
CIP
CIT
COND
DIP
FES
F&G
F&C
HDPE
HH
HYD
INV
PIV
PWW
PVC
RCP
TSV&8
UP
VCP
ABBREVIA nONS
GENERAL
ABANDON
ACCESSIBLE CURB RAMP
ADJUST
APPROXIMA TE
BITUMINOUS BERM
BITUMINOUS CURB
BOTTOM OF SLOPE
BOTTOM OF SLOP
CONCRETE CURB
CAPE COD BERM
CONCRETE CURB & GUTTER
ELEVATION
EXISTING
FOUNDATION
GRANITE CURB
GRANITE EDGING
MAXIMUM
MONOLITHIC CONCRETE CURB
MINIMUM
NOT IN CONTRACT
NU I I U ::i(;ALI:.
PRECAST CONCRETE CURB
PROPOSED
REMOVE
RETAIN
REMODEL
REMOVE AND RESET
REMOVE AND STACK
SLOPED GRANITE EDGING
STOCKADE FENCE
TOP OF SLOPE
TOP OF SLOPE
TYPICAL
VERTICAL GRANITE CURB
UTILITY
ASPHALT COATED CORRUGATED METAL PIPE
CORRUGA TED ALUMINUM PIPE
CUT AND CAPPED
CAST IRON PIPE
CHANGE IN TYPE
CONDUIT
DUCTILE IRON PIPE
FLARED END SECTION
FRAME AND GRATE
FRAME AND COVER
HIGH DENSITY POLYETHYLENE PIPE
ELECTRIC HANDHOLE
HYDRANT
INVERT ELEVATION
POST INDICATOR VALVE
PAVED WATER WAY
POL YVlNYLCHLORIDE PIPE
REINFORCED CONCRETE PIPE
TAPPING SLEEVE, VALVE AND BOX
UTILITY POLE
VITRIFIED CLAY PIPE
SITE PLAN NOTES
1. EXISTING CONDI1l0NS INfORMATION WAS TAKEN fROM A SURVEY PERFORMED BY HERITAGE
SURVEYS, INC. DATED OCTOBER 9. 2013.
2. ALL WORK AND MATERIALS SHALL COMPLY WITH THE TOWN OF AGAWAM REGULATIONS. BUILDING
CODES AND O.S.H.A. STANDARD&
3. CON1lRACTOR SHALL REFER TO THE ARailTECTURAL PLANS FOR EXACT LOCATIONS AND
DIMENSIONS OF VESTIBULES. SLOPE PAVING, SIDEWALKS. EXIT PORCHES. PRECISE BUILDING
DIMENSIONS, STAIRWAYS AND EXACT BUILDING UTILITY EN1lRANCE LOCATIONS.
+. ALL DISTURBED AREAS ARE TO RECEIVE MINI~UM fOUR INCHES OF TOPSOIL. SEED. MULCH AND
WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED.
5. ALL EDGES OF PAVEMENT TO BE CURBED. BACK OF CURB SHALL BE FWSH WITH GRADE
UNLESS NOTED OTHERWISE. ALL CURBING AS NOTED ON THE DRAWINGS.
6. ALL PAVED RADII ARE TO BE 2' UNLESS OTHERWISE NOTED.
7. ALL DIMENSIONS AND RADII ARE TO THE EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.
8. EXISTING PAVED AREAS ON SITE (i>TE DRIVE. SIDEWALKS, PARKING AREAS) SHALL RECEIVE A
SURfACE COURSE AS SPECifiED IN THE PAVING DETAILS. ADJUST S1lRUCTURE FRAMES TO
MATCH FINISHED GRADE.
9. ALL CONSlRUCTION IN TOWN RIGHT-Of-WAYS AND/OR EASEMENTS SHALL BE IN ACCORDANCE
WITH THE MADOT STANDARD SPECIFICATIONS.
10. IN THE EVENT OF DISCREPANCIES BETWEEN LOCAL SPECIFICATIONS Be STATE SPECIFICATIONS.
THE MORE SlRlNGENT REQUIREMENT SHALL GOVERN.
11. CO~I1lRACTOR SHALL REFER TO ARCHITECTURAL DETAILS AND SPECIFICATIONS FOR
REQUIREMENTS Of CONSlRUCTION AND JOINT SPACING Of SIDEWALKS. RAMPS. AND CURBING
ADJACENT TO BUILDING.
12. CON1lRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING IMPROVEMENTS
DURING CONSTRUCTION, SUai AS, BUT NOT LIMITED TO. DRAINAGE. UTILITIES. PAVEMENT.
S1lRIPING. CURB. ETC. REPAIRS SHALL BE EQUAL TO OR BETTER THAN EXISTING CONDITIONS.
13. THE CON1lRACTOR SHALL PROTECT ALL BENCHMARKS AND PROPERTY MONUMENTA TION.
BENCHMARKS AND MONUMENTATION DISTURBED DURING CONS1lRUCTION SHALL BE REPLACED OR
REPAIRED BY A LICENSED SURVEYOR AT THE CON1lRACTORS EXPENSE.
14. ALL S1lRIPING. PAVEMENT MARKINGS, AND TRAFFIC SIGNAGE SHALL BE IN ACCORDANCE \\1TH
THE MANUAL ON UNifORM 1lRAFFiC CONTROL DEVICES (MUTCD). LATEST EDI1l0N, UNLESS
OTHERWISE NOTED ON THE PLANS. STRIPED AREAS SHALL BE 2 FEET O.C. UNLESS
OTHERWISE NOTED.
15. CON1lRACTOR SHALL KEEP ACCURATE AS-BUILTS AND SUBMIT THEM TO OWNER 'MTHIN
30 DAYS OF PROJECT COMPLETION.
SITE GRADING NOTES
1. THE CONlRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION
OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE
VARIOUS UTILITY COMPANIES. AND I'.I-IERE POSSIBLE. MEASUREMENTS TAKEN IN THE
fiELD. THE INFORMA TIDN IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONlRACTOR SHALL CONTACT DIG SAFE 0 1-888-DIG-SAFE AT LEAST 72 HOURS
PRIOR TO BEGINNING CONSlRUCTION TO REQUEST EXACT FIELD LOCATION Of UTILITIES.
IT SHALL BE THE RESPONSIBILITY Of THE CONlRACTOR TO RELOCATE ALL EXISTING
UTIUTIES WHICH CONfliCT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PlANS.
2. ALL CUT OR fiLL SLOPES SHALL BE 3: 1 OR flATTER UNLESS OTHERWISE NOTED.
3. PRECAST SlRUCTURES MAY BE USED AT CON1lRACTORS OPTION.
4. STORM PIPE SHALL BE AS FOLLOWS UNLESS omERWlSE NOTED: HIGH DENSITY
POLYETHYlENE PIPE (HOPE) SMOOTH INTERIOR/ANNULAR EXTERIOR. PIPE JOINTS AND
fiTTINGS SHALL CONFORM TO AASHTO M252 AND M294.
5. EXISTING DRAINAGE S1lRUCTURES TO BE INSPECTED AND REPAIRED AS NEEDED. AND
EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SIlT AND DEBRIS.
6. EXISTING GRADE CONTOUR INTERVALS SHOWN AT 1 fOOT INTERVALS.
7. PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1 fOOT INTERVAL&
8. IF ANY EXISTING S1lRUCTURES TO REMAIN ARE DAMAGED DURING CONS1lRUCTION IT
SHALL BE THE CON1lRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE
EXISTING S1lRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR
BETTER.
Q All C:Tn~u PIPI=:C:: ~""'Tl::~I",e ~TAueTUR~~ S:I-IALL gc: CROUn:o TO AIO:CU~1i: bONN£OTlON
AT S1lRUCTURE IS WATERTIGHT.
10. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE flUSH WITH PAVEMENT. AND
SHALL HAVE 1lRAFFIC BEARING (H20) RING Be COVER MANHOLES
11. CON1lRACTOR SHALL ADJUST AND/OR SAWCUT EXISTING PAVEMENT AS NECESSARY TO
ASSURE A SMOOTH FIT AND CONTINUOUS GRADE.
12. CON1lRACTOR SHALL ASSURE POSI1lVE DRAINAGE AWAY FROM BUILDINGS FOR ALL
NATURAL AND PAVED AREAS.
13. AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES Of TOPSOIL.
CON1lRACTOR SHALL APPLY STABIUZATION fABRIC TO ALL SLOPES STEEPER THAN
3H'lV. CON1lRACTOR SHALL SEED DISTURBED AREAS UNTIL A HEALTHY STAND OF
GRASS IS OBTAINED.
14. ALL STORM MANHOLES SHALL HAVE A SMOOTH UNifORM POURED MORTAR INVERT
fROM INVERT IN TO INVERT OUT.
15. IF CONTRACTOR RELOCATES OR SETS NEW BENaiMARKS, THE VERTICAL ELEVATIONS Of
mE BENCHMARKS SHALL BE SET, BY A UCENSED SURVEYOR. WITHIN A TOLERANCE OF
0.010 FT.
16. ALL UTIUTY ADJUSTMENTS SHALL BE COMPLETED PRIOR m FINAL PAVING
CONS1lRUCTION.
SITE UTILITY NOTES
1. ALL fiLL MATERIAL IS TO BE IN PLACE. AND COMPACTED BEfORE
INSTALLATION Of PROPOSED UTILlTIE&
2. CON1lRACTOR SHALL NOTIfY THE UTILITY AUTHORI1lES' INSPECTORS 72 HOURS
BEfORE CONNECTING TO ANY EXISTING LINE.
3. GRAVITY SANITARY SEWER PIPE SHALL BE AS fOLLOWS: SDR35 PER ASTM 0
3034, FOR PIPES LESS mAN 12' DEEP SDR26 PER ASTM 0 3034. FOR PIPES
MORE THAN 12' DEEP
4. WATER MATERIALS SHALL BE AS fOLLOWS:
4.1. WATER MAIN: DUCTILE IRON CLASS 52. CEMENT LINED DOUBLE THICKNESS.
TYTON JOINT(AWWA Cl04/A21.4. AWWA Cll1/A21.11, AWWA C150/A21.50,
AWWAC151/A21.51)
4.2. WATER MAIN fiTTINGS: DUCTILE IRON CLASS 350 -MECHANICAL JOINT
w/ MEGALUG (AWWA Cll0/A21.10. AWWA C153/A21.53)
4.3. RESTAINT SYSTEM: MEGALUG SERIES 1100 I< SERIES 1100 RES1lRAINT
HARNESS OR APPROVED EQUAL. RES1lRAINT LENGTHS AS SHOWN ON
UTIUTY PLAN.
4.4. GATE VALVES: AWWA C515, RESIUENT-SEATED. DUCTILE IRON BODY,
MECHANICAL JOINT, EPOXY COATED, STAINLESS BOLTS Be NUTS. NRS,
OPEN LEFT. AMERICAN fLOW CON1lROL. McwANE GROUP (KENNEDY. CLOW).
MUELLER GROUP (MUELLER, US PIPE). OR APPROVED EQUAL.
4.5. VALVE BOXES: 5 1/4" X 60". 2 PIECE SLIDING TYPE W/TOP flANGE. NO
KNOBS, BELlED BASE. DOMESTIC ORIGIN. TOTAl WEIGHT -100 LBS
(BASE. TOP AND COVER). COVER MARKED 'WATER'.
4.6. • .. ALL MATERIAL IS TO BE "NO LEAD" TO COMPLY WITH THE FEDERAL
'REDUCTION Of LEAD IN DRINKING WATER ACT', UNLESS SPECIFICALLY
EXEMPTED***
4.7. PRESSURE TEST (BY CON1lRACTOR): MUST PRECEDE CHLORINATION TEST
fOR 2 HOURS AT 1.5 TIMES STATIC PRESSURE (OR 150 PSI MIN.) -SEE
DETAILED METHOD BY TOWN Of AGAWAM.
4.8. CHLORINATION (BY CON1lRACTOR): USE LIQUID CHLORINE -CONTINUOUS
FEED METHOD. QUICK TABS MAY BE USED ONLY \\HH PRIOR WRlmN
APPROVAL BY THE TOWN ENGINEER -SEE DETAILED CHLORINATION
METHOD BY TOWN OF AGAWAM.
4.9. ALL WATER SYSTEM MATERIALS AND PROCEEDURES SHALL COMPLY WITH
TOWN OF AGAWAM WATER DEPARTMENT STANDARD&
5. CON1lRACTOR SHALL MAINTAIN A MINIMUM Of S' COVER ON ALL WATERLINES.
6. WATER AND SANITARY SEWER SEPARATION SHALL BE 10' MIN. HORIZONTAL
FROM OUTSIDE EDGE OF PIPES. IF HORIZONTAL SEPARATION CAN NOT BE
OBTAINED. THE WATER LINE MUST BE INSTALLED A MIN. OF 18" ABOVE
SANITARY SEWER. THE SANITARY SEWER UNE SHALL BE DUCTILE IRON PIPE
WITH MEaiANICAL JOINTS AT lEAST 10 FEET ON BOTH SIDES OF CROSSING.
mE WATER LINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIAlE
THRUST BLOCKING AS REQUIRED TO PROVIDE A MINIMUM OF 18" VERTICAL
CLEARANCE. MEETING REQUIREMENTS Of ANSI A21.10 OR ANSI 21.11 (AWWA
C-151) (CLASS 52).
7. UNES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED
BEfORE BACKFlUUNG.
8. TOPS OF EXISTING MANHOlES AND CATCH BASINS SHALL BE RAISED AS
NECESSARY TO BE fWSH WITH PROPOSED PAVEMENT ELEVATIONS. IT IS NOT
ALLOWABlE TO HAVE STRUCTURE TOPS ABOVE PAVEMENT GRADE fOR
EXTENDED PERIODS Of TIME OR DURING WINTER MONTHS.
9. ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 26 DAY
COMPRESSION S1lRENGTH AT 3000 P.S.1.
10. DRAWINGS DO NOT PURPORT TO SHOW ALL EXISTING UTIUTIES.
11. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION Of
ANY NEW LINES.
12. REFER TO ARCH/MEP INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL
UTILITIES.
13. CONlRACTOR IS RESPONSIBLE fOR COMPLYING TO THE SPECIFICATIONS OF
THE TOWN OF AGAWAM ~TH REGARDS TO MATERIALS AND INSTALLATION OF
THE WATER AND SEWER UNE&
14. ALL NECESSARY INSPECTIONS AND/OR CERTIfiCATIONS REQUIRED BY CODES
AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO
ANNOUNCED BUILDING POSSESSION AND THE FINAL CONNECTION Of SERVICE.
15. CONlRACTOR SHALl COORDINATE WITH ALL UTILITY COMPANIES FOR
INSTALLATION REQUIREMENTS AND SPECIFICATIONS.
16. CONlRACTOR SHALL COMPLY WITH THE LA TEST OSHA STANDARDS OR
DIRECTIVES OR ANY OTHER AGENCY HAVING JURISDICTION fOR EXCAVATION
AND lRENCHING PROCEDURES. THE CON1lRACTOR SHALL BE RESPONSIBLE fOR
THE DESIGN AND MAINTENANCE OF ALL SUPPORT SYSTEMS. SLOPING.
BENCHING. AND OTHER' MEANS Of PROTECTION.
17. CON1lRACTOR SHALL ENSURE UNINTERRUPTED SERVICE OF ALL EXISTING
UTIUTIES ON THE SITE INCWDING BUT NOT LIMITED TO SEWER, WATER •
ELECTRIC, GAS. TELEPHONE. CATV AND OTHERS.
16. ALL SITE ELEClRlCAL SHALL BE IN ACCORDANCE WITH APPUCABLE
STANDARDS.
I-ffJ w~ u-:::)g
O~ C~
f../)
u.J r-
CdO
OZ
Z .....I « ~
u.J
u.J
lJ
u.J
.....I
f-
Z W l/)
~Z uO
«i= Z« «> ~O
I Z u~
~o(J
W
l/)Z ~O
....Jf-<t;-uO -0 z« -....J
U
A
Scale:
Designed:
Drawn:
Reviewed:
Date:
Z
u.J
lJ
N.T.5.
CST
JBB
TIH
Dec. 31, 2013
SHEET
C2
2 OF 7
Project No~
1355,001
NOTES
1. ESTlMAl£D LOCATION OF ZONE UNE DEMARCATING BUSINESS A AND RESIDENTIAL A-2 BASED
ON TOWN OF AGAWAM ONLINE GIS INFORMATION.
2. EXTENTS OF EXISTING GRAVEL TURNAROUND BASED ON AERIAL PHOTOS OF THE Sll£.
CEMETERY
LANDSCAPiNG
CEMETERY
LANDSCAPING
\)
'i
IJJ o o
7".
COMMONWEALTH OF MASSACHUSETTS
VETERAN'S CEMETERY
BOOK 9872 PAGE 146
PLAN BOOK 2 6 PAGE 109
CEMETERY
LANDSCAPING
CEMETERY
C~
CEMETERY < SPRINKLER ~. LANDSCAPING ~~ ) HEAD ELECTRIC ;~~;~DUMPSTER ~ ~ < (TYPICAL) I ACCESS _mIH~ ~ l _~ ____ SEE DETAIL) _ T ______ :::::;::_ ..... ~_.../'-_ 575'52'00"£ -~ _____ --:ti~-____ ....".,~ ~~::~I,C I
" /'-~ -rr~T~n==fr¥~:::;'~6'~9'~~. "_~' __ ~RO~OF~DR~A~~N',~' ~";;;;;;;;;~ ;;;;;:;2;;;~t~;;~' Ir' '7'77.'7777-' ffTF.l-~ ,-~~. -; _ r ---=-;;:;;O>I~v~----",v _~.J.-I 10-,.0----'-""" ---'til" --'\\. .. ~~---""" --"'" @
1---6B.3' _ '0 >IU<" ~ 'u::. U/// '7 9.0' "" ~ M"ll:.~t~~~=.-=1A~= ~
I I b u///7777///////. u. -~,.". ~ .. , x'Q'" __ ---,._ ;"-,~ "i' ~ ~ v. ~.v, "'-I.. , SIGNAL~ ~
I r.:'\' I . . :; ~ I (;\.6 I I CONTRO, --Ki\ Il <D
,
\.3) 18.0' ". RIT :;: I PROPOSED "' ~ ~ i : , CA8INEi/~ 11 ';J, I ~t~M EP.AA~ ~ I~ CONCRETE PAD '\: 24.0' ~",,---+,-'I, \ :xx A I' 1 0 ~~ gil!! STONE \ -180 l---.l 0) I: GUARD ~ ~
. X/. x,Q ~. ' -9.0 I--r-'o ~~:~~ g ~~ FfUlDOC< ~~I~I~~ ~I~ B~I~~~8G "'~:~~ ". ~ : :r! POST ~ "l>
ill" 'X ->-. 2.174 SF ~ 69.5. 4,556 SF '1"1 ~ .0.92 /.1-'_' ~~~~. 5°'1Jij 11M -,~,;:;; I Z
III :x:"').X';i I ~''-PROPOSED :;; "'I ~~90' I 0 ,L<. v X )<xuil)( 39.0' CONCRETE PAD ~ --' ........ "",.,. I'l' 0 0 .,,--'¥. (J) /' 0 x~, X ~ PR I SEE ACCESSI8LIE"-~~ -PAVEMENT I '\~I' ~ -\
TOP WNQlEIE -<
H RETAI~h~g6~t : MI! ~, I[§!!J I .. .,. THRE~<OI.O" .. , .. ",. EP~6o.,../ ASPHALT ----iI ~ Ill( 0 ~
LOAM & SEED EXISTING-/~ -r )< X ~::~T===:=='/~;-' .~":",,::c_\.\.~ ~. ~ '\. 71.70 .. 60.~ ";-60,.7. 'i. ~ r.;V~~'l'h~~~rJI.~~ ____ ._~===~=l'I==;~R!lkrT=~='f'~., %
Xx 'X -----·---!---<:m<'<"'n;-AN7'"I-·-,..., ~ 58:~' ,oHM" COMPA~1EfN::~~ 16.0' 15' SIDE >t,,,Al>\ -PR-OP-O-sm-----I . ..__SAWCUT EXIS11NG SAWCUT EXISTING I ~:~~~~ \ X><X X >s< . ~ PAVEMENT PAVEMENT .,...__ASPHALT-16.4' ~~;~~:~X~~~~:6~6'~55:;::~~~'=~-:I~=':;~~~2~8~.7~'~:;;;~CO~N~CR~ETE~~PA:D~=~·"~·'~oo~~~::==<:~~c::===~EP~-6O'~'!"~~~:;~~O~VE~R~~~Y~~~~~,::""""~~~~~~I~~~E:~ COMMONWEAL TH OF MASSACHUSETTS < ~IT ?QR H' 1!11 I Rli ~~~\'.\'
VETERAN'S CEMETERY - - - -- --,-N75'52'OO"W -- -- -- -- -- -~t"M ~~
BOOK 9872 PAGE 146 / 0.,·
PLAN BOOK 26 PAGE 109 < ABUTTER'S "Af'tL
o
CEMETERY
LANDSCAPIN G
ll1"o.wln9' ~\1355-0D1 \dwQ\\IIo."+<I"6_dr-Q.wlngC\t355-001 !lo.".n .. o
I
--
PIQ<ET BU ILDING A ~ STONE ~ ~
WILLIAM A. & JOANNE S,
SALTMAN
BOOK 14743 PAGE 313
PLAN BOOK 194 PAGE 51
---------
J
RETAINING
WALL
\
,;,
._---.. -.------------_. ----_._----_._---
ZONING TABLE
ZON ING REGULATIONS REQUIRED
REQUIREMENTS . RES. A-2
MINIMUM LOT SIZE 15,000 SF
MINIMUM LOT FRONTAGE 110 FT
BUIUOING SETBACK
FRONT YARD -
SIDE YARD 15 FT
REAR YARD 20 FT
MAXIMUM BUILDING HEIGHT 35 FT
MAXIMUM BUILDING COVERAGE 40%
ZONING DISTRICT: BUSINESS A & RESIDENTIAL A-2
• FRONTAGE IN BUSINESS A .
REQUIRED
BUS. A
-
-
35 FT o FT -
45 FT
50%
•• 30% COVERAGE IN RESIDENTIAL A-2, 17.5% COVERAGE IN BUSINESS A.
PARKING SUMMARY
REQUIRED
STANDARD SPACES (9' x 16') 15
ACCESSIBLE SPACES 1
TOTAL PARKING SPACES 16
NOTES: PARKING STALL NUMBERS BASED ON THE FOLLOI'l1NG.
4,200 SF OFFICE SPACE (4,200/300 = 14 SPACES)
PROVIDED
28,017 SF
95 FT'
100.0 FT
16.9 FT
66.3 FT
29 FT
24%**
PROVIDED
15
1
16
3,165 SF STORAGE SPACE (3 EMPLOYESS/ 1.5 SPACES = 2 SPACES)
1,470 SF COMMON AREAS OCCUPIED BY EMPLOYEES IN OFFICE AREA
\
GRAPHIC SCALE
( IN FEET)
1 inch = 20 ft.
I-
Z UJ rJ)
~oZ lJ «-zl-«<C ~6
I Z u~
~~ UJ
rJ)Z ~o --ll-«-u D
-0 z« --l
U
-
C3
3 OF 7
Project No.:
1355"001
0 ~ • " •
" ~ i t ,
~ " ,d t my .. --• • , ,
" :!;:'!: • , i'~ ~ ,
'f i ~.
is ~ ; .~ " • " r ~a • " , :] ,\ ""
NOTES
1. SITE SOILS CLASSIFIED AS UNADILLA VERY FINE SANDY LOAM BY NRCS SOIL SURVEY -
HYDROLOGIC GROUP B.
2. SITE COVERAGE IS SUMMARIZED AS FOLLOWS:
EXISTING PROPOSED
COVER AREA (SF) CN COVER AREA (SF)
BUILDING 4,556 98 BUILDING 6,730
PAVEMENT 11 ,900 98 PAVEMENT 10,610
GRAVEL 1,641 85 GRAVEL 0
GRASS 9,921 61 GRASS 10,678
TOTAl AREA 28,018 TOTAL AREA 28,018
AVG. CN 84.1 AVG. CN
eN
98
98
85
61
83.9
CEM E1ERY
LANDSCAPING
--,
COMMONWEAL TH OF MASSACHUSETTS
VETERAN'S CEMETERY
CEMETERY
LANDSCAPIN G _
BOOK 9872 PAGE 146
PLAN BOOK 26 PAGE 109
CEMElERY
LANDSCAPING
--__ 69----...
I iSILT FENCE. SEE DETAlC., --_-
PROPOSED INflLTRATlON AREA
CE MET[F""~ Y ~. ,.-/ -',
_+-__ .L _ _ _ _ __ "'"""':"_
I e
! ~./_-~ -- - - - -- ----
;" .
CONC. fAil... -
-~%"" -~---
69.5 ~~ ~ pb;OSED (" --
-AilDlTlON \
2.174 SF
lNV OUT 6"-61 .52
SU'-lP-61.6 EXISTING
FFLR DOCK BUILDING
59 . .59 ".556 SF
T-JP CON~ETE
~t:TAlNINO WALL
65.05
CONC. PAD 0 2"
PR()PO~SED __ ·lSO •• ' LAN!flC)F*lG \
I
FI'<; ~ 69g;p _ SPRINKLER
CONHEGTlON
THRESHOt.O ~=~~~~~ ~t--I --
1 /1
I ( I
I I I
I .
1 I
1 I
I I
I 1
I
COMMONWEAL TH OF MASSACHUSETTS
VETERAN'S CEMETERY
BOOK 9872 PAGE 146
PLAN BOOK 26 PAGE 109
I 1
I 1 Ii
/'" 1 I \ ,... 1 ,
"'I \II I I \
I I
1 /
I I
I
CEMETERY
LANDSCAPING
0
I
I
I
I
I
I
t..
----
I
I
lC 69.0
8C 66.5
SILT FENCE. SEE DETAIL
r-I;ONC. PAD
II 1: 20
...,.... ------.... --'" \ \ \ \. \ \ \ "'\\.
\ --\ \
WILLIAM A. & JOANNE S.
SALTMAN
BOOK 14743 PAGE 31 3
PLAN BOOK 194 PAGE 51
\ \
J
60.40
\
ADJUST RIM
TO 60.04
\
__ G--'"
RII.(",,~1.~1
(1) INV IN 12· ... 52.89 I;'
(2:)iNC IN 12-.. 5-4-.49
~\I OOT 12~ =52.04 \
\
GRAPHIC SCALE
20 0 10 20 40 80 5-. 1_!-I __ ~L~~~j I
( IN FEET)
1 inch = 20 ft.
~
V
Z -0 « ~
V
--II-<~ u O
-0 Z« --I
U
-\1
z « --J
0-
~ ---J -l-~
TIH
Date: Dec. 31, 2013
SHEET
C4
4 OF 7
Project No;
1355-001
NOTES
1. SITE LlGHnNG DESIGN BASED ON COMMERCIAL BUILDING ENERGY
ALLIANCES (CBEA) LED SITE LlGHnNG SPECIFICATION VERSION 1.3.
RELEASED 2/15/2012 FOR LIGHTIN G ZONE 2.
2. CALCULATIONS PERFORMED AT L85 50.000 HOURS.
CEMETERY
LANDSCAPING
-0
'i
m o o
A
COMMONWEAL TH OF MASSACHUSETTS
VITERAN'S CEMITERY
BOOK 9872 PAGE 146
PLAN BOOK 26 PAGE 109
CEMETERY
LANDSCAPIN G
(
CEMETERY
LANDSCAPING
(
\
\
CEMETERY
LANDSCAPING
( SPRINKLER I
~A. HEAD ELECTRIC ~ < ! (m'ICAL) I ACCESS
Lumlnaire Schedule
S~bol _,Q~tLy __ -+~Lo~b~el-4~A~rr~On~ge~m~.~nt~ __ ~hL7LF~~D~es~c~rip~t;~on~.-__ -+~To~to~I~W~ot~ts~fiLu~mi·~L~um~.~ns~
• '4 WWE SINGLE 1.000 EESW WE 40A 80 1290
.. 1 PM SINGLE 1.000 EPCC_A441P____ 189 2000
Calculation Summary
Lobel Avg Mox Min Avg/Min Max/Min
Main Dri .... e 0.73 i ,6 0.2 3.65 8.00
Parking 0.89 2.0 0.4 2.23 5.00
Properly Line 0.04 0.3 0.0 N.A. N.A.
. ,
TRAFFIC I
dr-.O""""lho,.ur--m -"'6 .... ' -.... 0 .... 1 -m'l ---,O'r1. or--m'l -'I:0'"l!0-""'01"'/,.0 -m'l -'"I!6.'?!:ij)-m'l -"'0."'0-""6"'"'.0 -.. (i.Q -"'0.""0-(i.Q -"'o"ll'o"-""61n.o -L-~ -~ -: -I-l --OW---:. 'll::-iv 1
__ OHV --.,--
__ r--t~ 7~,~~;N"" .'W777777:"17""'~N~";~~N~'m,?;;.;;;,iJ. /~. ir----'--~~ --. --, --, --1
r/ ~ I@l ~ 1 EXISTING UGHT TO REMAIN...!:, 1
"\~~"""=---:p,t=---r-
Si GN AI. . "'II ':, \Ill
CEMETERY
LANDSCAPING
J b.4 .... 1:0' /,,; " //////
p O 'b.7 b.7 I'W BIL ~~ : i :
L b.9 I." "~K" 0 ~ ~ ~2~K: : ~ r ''-1 ',6 I,...: ~1ci MH PROPOSED ~ EXISTING BUILDING
po
I
~ [.0
< .0
\ I
L!,S... "" ADDITION I!iI ~ ~ BUILDING N 1408 JI .1..... '.0 .0.. 2.174 SF ~ 4.0~ SF . ~
,. ,.0" b ~ :1 "'" , ~ ~ -'.0 ~ ~ I' 1 FRONT PARKING AREA ~ ~/./ '. ~""'::"'~'Lf<"ifLitL'!""f "v. 1 UGHTING PROVIDED BY ,~~:;: EXISTING RXTURES TO
lID
PAV[MENf
b.6
b.7
'--!-..... 'o •. 5
I
I
\
I
I
\
CONTROl~ II
CABINET ,-;=
GUARD~T -
POST
:~~~~~~'~MH::::::::~~~b~l~~~'_"~'~ ~O'~\:~~~~'::::~~~~~~~~~~~~~~~::'~::~1-RE_M_AI_N. ~ '-4'", ~~MH ~ I I, ,_ BIT
, 2 b.5 b.7 '.0 b.6 I 1.:> 1 - - -~~KM
,f"'" p.D b.!
b.4
COMMONWEAL TH OF MASSACHUSETTS <
VETERAN'S CEMETERY
BOOK 9872 PAGE 146
PLAN BOOK 26 PAGE 109
o
CEMETERY
LAt~DSCAPING
p.o 'b.3
f
I
I
. '.J 'b b.6 I" '.4 • . \
' 1 b.2·
J 'b.2 b.5 ,b.4 1 u.9 'b.7 0·31 BIT
--
ABUTTER'S
BUILDING
WILLIAM A. & JOANNE S.
, SALTMAN
BOOK 14 74J PAGE JIJ
PLAN BOOK 194 PAGE 51
------------ ----.-
I
I
J
--"'.KM
42'
IJAPlE
RETAINING
WALL
,.--------------------------
\
\
\
I _____ ----------C~-
\j:
d c
-\
\
GRAPHIC SCALE
20 0 10 20 40
~S~-)i}.-·~~ ~
( IN FEET )
1 inch = 20 It.
60
I
V M
-~
I-u.J
~ o
I-o
I c...
I-
Z w l/')
~OZ o -<-z~ -< ~6
I Z u~
~a'd w
l/')Z ~O --JI--<-uO -0 z-< --J
U
Drawn:
Reviewed:
Date:
:5T
JBB
TIH
Dec. 31, 2013
SHEET
C5
5 OF 7
Project No.:
1355·001
.. -.~.-.--.. -------------~---------.------
1.5" ASPHALT SURFACE COURSE
(TOP COURSE M3.11.00)
l~il§~~~li~;li~I~== 3" ASPHALT BINDER COUIiSE
(DENSE BINDER COURSE M3.11.00)
12" PROCESSID GRAVEl
MHO M1.03.1
'--(;OMPACTED SUBGRADE
LOAM AND ORGANICS
Notes:
1. PAVEMENT THICKNESS PER TlD\\I.j OF AGAWAM SUBDIVISiON
REGULA liONS FOR A "PLACE" OR "LANE".
2 SEE SITE LAYOUT PLAN FOR PAVEMENT 'MOTH AND LOCAllON.
2 SEE GRADING PLAN FOR PAVEMENT SLOPE
FULL DEPTH ASPHALT PAVING
Notes:
~ 1.50" ASPHALT SURFACE WU~""1 (Tor oounce: Ma.11.00)
_-~ BITUMINOUS TACK COAT
EXISllNG PAVEMENT
1. SEE SITE LAYOUT PLAN FOR PAVEMENT WIDTH AND LOCAllON.
2. EXISllNG PAVEMENT CRACKS MUST FIRST BE SEALED WITH
RUBBERIZED BITUMINOUS CRACK FILLER. CRACKS MUST BE FlREE
OF DIRT DUST AND DEBRIS.
ASPHALT PAVING OVERLAY
COMPACTED SUBGRADE
STRIP LOAM AND ORGANICS
Notes:
6" CONCRETE PAVEMENT
MODULUS OF RUPTURE: 'srn'FNc:'iH""1 4500 PSI 28-DAY COMPo
1 1/2" AGGREGATE
CONCRETE 6" ± 1" AIR ENTRAINED
12" CRUSHED STONE
MADOT M2.01.7
CONCRETE SLAB SHAUL BE REINFORCED ~TH *4 BARS II 24" D.C. EACH WAY
CONCRETE PAVING (DUMPSTER PAD)
SCAlE: Paving Details 2/27/07
PAIJE-A-.3 NOT TO SCALE
S"XS" VINYL POST '
(TYP) FILL END
:1.. IN CORNERS Of
S'XS" VINYL POST
(TYP)
f ' 1'1"" POST W/ CONCRETE I r.'.'.' POST w/ COO CRETE
n _---(2) #5 BARS PLACE
j POST I 6.0' I , __ -4" PIPE BOULARD
SEE DETAIL
H--~6"
MIN IS" ABOVE GRADE
(2) /IS BARS PLACE
IN CORNERS OF
POST
1/2" JOINT W. SEALANT
II
.......L.J.--r--I. fF ~,."...--
FROST DEPTH .: .. '.
(3' MIN) :. r; .;
"1 .,'
". '", . -q 2.5' ~
DETAIL B -END POST
6.0'
30"XI8" MIN
CONCRETE FOOliNG FR(~T
6" COOCRETE SLAB
SEE DETAIL.
18' , ~IN
CONCRETE FOOllNG
DETAIL C DPI CAl pOST
5"XS" MIN
HOLLOW VINYL
FENCE POST
(TYP)
VINYL FENCING PER
MANUfACTURER
1->+------10.5' --+------1 r NEW 6" THICK
12')(10' LtlN
CONCRETE SLAB
10.0'
SCAl£
NOT TO SCAlE
8.0' MAX SPACING ~
4" STD PIPE
BOLLARD FILL
~TH CONCRETE
(TYP)
ASSURE THAT
EXISllNG SiTE
GRAIDING
PROVIDES
DRAINAGE SO
PONDING DOES
NOT OCCUR
9.5' CLEAR
MIN. OPENING
'tlNYL DUMPSTER ENCLOSURE
~TH #4 BARS II
24" O.C. EACH WAY
f
4.0'
FlROST DEPTH
(3' MIN)
I
.• ,
1/2" MIN
CROWN "T TOP
4" STANDARD
PIPE BOULARD
ALum WITH
CONCRETE
18' ~ ~IN
CONCRETE
FOOTING
DETAIL A -TYPICAL BOLLARD
Vinyl Fence Dumpster Enclosure 2/6/03
fNC-4 \
r
SURFACE
TREATMENT
VARIES
RADIUS (TYP.)
SLOPE
SCALE:
NOT TO SCALE
-
'--·COMP/ICllm GRAVEL
(l.1f MAX STONE SIZE)
Note:
SUBGRADE
ALL CURBING TO BE MACHINE EXTRUDED
Bituminous Curb (BC) 2/6/0.3
C&$W-A-l
REFLECTORIZED (ENG. GRADE)
k VWHITE TEXT AND SYMBOL ON o BLUE BACKGROUND (TYP.)
HANnlCAPPED
PARKING .... ""' .... ~~~~ WHEN
.... -I ............... REOU IRED
VAN v------
ACCESSIBLE ,
ALUM IN UM SIGN (TYP.)
$300 FINE
• • • • · •
iVD.P.W BREAKAWAY
: POST • · • " • · , · • • • • • • • • • ·
PERMANENTL Y
:VINSTALLED IN TO I FINISHED GROUND
• • •
SCALE; N. I.S.
HANDICAPPED
PARKING
SPECIAL PLATE REQUIREO
UNAUTHORIZED 'v[HICLES
MAY BE REMO\{D AT
OIl!iER'S EXPENSE
tf.QE; MAXIMUM MOUNTING DISTANCE FROM HEAD OF STAll IS 10'
PLEASE SEE' MGl C.40§21-22A, AAB 521 CMR 2.3 .00. AGAWAM CODE §169-28
DRAWN BY: JaD
IAt\TE; 01/08/tO
OWG. NO.: 1
APFROVED BY; Mtt
PROJECT
TOWN OF AGA WAM
CONSTRUCTION STANDARDS
SHT. NAWE SHT. NO.
ACCESSIBLE P/,RKING SIGN A-I
SCALE:
COMPACTED OR
UNDISTURBED
SUBGRADE
NOT TO SCALE
I.
II-.----,----r~ LIGHT POLE & ANCHORING
SYSTEM BY MFG.
I" CHAMFER
LIGHT POLE BASES
TO BE PAINTED YELLOW
#3 HORIZONTAL liES I» 12" C.C.
4-#5 VERTiCAL-EQ. SPACED
FINISH GRADE (MATERIALS VARy)
63 REBAR
#5 REBAR
BOLT LAYOUT
& MOUN liNG
PROCEDURE AS 2" COVER
PER MFG. SPECS ON REBAR
Section plan
Notes:
light Pole Foundation Detail
,8 t
.1
vi ~ .. ..,
'" ~ ... ..,
'" u u '"
2/6/0.3
u-,
MOUNT-,-----'
SIGN II
HERE ·
II
"U"-CHANNEL POST II
(2 lBS.jFT.) .....
WHEN SIGN IS ~ r ~
IN PAVED AREAS, "i I
USE 6" PIPE
OOLLARD FILLED wi CONCRETE
AND PAINTED
TRAFFIC YEllOW
SLOPE TOP
OF CONCRETE --,
I I
I • I
1 '1
rfOj
I I
Notes:
)
b I n
, ,....
Oz 1-
".3
1. ALL SIGNS SHAUL COMPL Y ~TH U.S. DEPARTMENT OF TRANSPORTATION.
SCALE:
NOT TO SCALE
FEDERAL HIGHWAY ADMINISTRA llON'S "MANUAL OF UNifORM TRAFFIC CONTROL
DEVICES', LOCAL CODES AND AS SPECIFIED. MOUNT SIGNS TO POST IN
ACCORDANCE ~TH MANUFACTURER'S INSTRUCTIONS.
Standard Sign Base 2/6/03
SGN -l
I-
Z
-< f-u.J o
L.U V')
66 <Cf= Z<C <C> ~o
I Z
u~
~c(!
L.U
V')Z ~o -.....JI-<C-UO -0 Z<C -.....J
U
C6
6 OF 7
Project No.:
1355"001
• • z
SC"'""
UNDISTURBED
EARTH OR---
COMPACTED
FlLL
LINE
NOT TO SCALE
12"MIN. 0.0. 12"MIN
FINAL
BACKFILL
,~~~a~I~~~t3 4" BEDDING ~ (MIN.)
WATER LINE
Utility Trench
~'IN"'L lRA TlC)N A TEA BOn~ -
ELEV. 67.0
STAND PIPE -ELEV 57.70
LOAM &: SEED
2/6/03
GU-2
5' CLEAR ZONE
SCALE:
NOT TO SCALE
UNDERDRAIN INVERT =
EXISTING SUB-GRADE
TOP Of INFILTRATION
AREA -ELEV, 58.2
ADJACENT PARKING LOT
Infiltration Area Cross Section with Drain .. DATE:
6/30/08
2' SO x 6" mlCK
CLAS~ g CONCR~~
VALVE BOX TO SUIT ~~Eu~ii~;~III.~~ AND DEPm OF BURY "
ALVE
TAMP BACKFILL
WATER e,,1 el:.-~
SCA.LE:
NOT TO SCALE Gate Valve
I)!" x I)!" x 4' WOOO STAKE
OR APPROVED ~UUAL-,
WORK
AREA
SILT FENCE-"
FlOW
TOP or
PLACE 4" OF FABRIC
ALONG ~~,~~:~~Wt; FROM e,
BACKFILL
. (MIN.)
SCALE:
NOT TO SCALE Silt Fence Barrier
ADJUST TOP SECTION
TO FINISH GRAOE
VALVE BOX TO BE
ENTIRELY SUPPORTED
BY CONCRETE BLOCKS
OR BRICKS TO SUIT.
VALVE BOX MUST NOT
BEAR ON VALVE OR
PIPE.
12/21/04-
W-5
I II
~ V PROTECTED
AREA
Wood Stoke
Joint Detail
2/6/05
SED-1
REDUCER FrlrnNG--1
AS REQUIRED
45' R,NIO---t-
SCI\LE:
NOT TO SCAlE
GALVANIZED ~ INCH WIRE ~ESH SCREEN PIPE CAP wi STAINLESS STEEL HOSE
CLAMP TO SECURE SCREEN
DOWNSPOUT
FASTENER
DETAIL
. MAX
1 % MINIMUM SLOPE
WYE CONI~ECTION·.1
Downspout Rain leader
COLLECTION PIPE
(SIZE PER PLAN)
2/6/03
0-33
~ ~ ~
I!! i
is " ~ u
" ~ 0
• ~ "-ID "-~
• ID • M ru . 2
I-Z w IJ')
~Z GO «-Z~ r-LU «> LU « ~O ~ ~ r-
I Z l.I'l ... ~~ U~
~a(J «3: ~« UJ
IJ') Z co <.J UJ 0 0 « ~ "<t' -r-....JI-«-
U Cl
-0 Z« -....J
U
TIH
Date: Dec. 31, 2013
SHEET
C7
7 OF 7
Project No;
1355·001