Loading...
8258_SITE PLAN - SPRINT SPECTRUM LP - 198 SPRINGFIELD ST. P(Ktc- ru ry) LP , 0 0 AGAWAM OFFICE OF PLANNING & COMMUNITY DEVELOPMENT SITE PLAN REVIEW REVIEWER: D. Dachos DATE: June 4, 2003 DATE RECEIVED: May 9, 2003 DISTRIBUTION DATE: May 9, 2003 PLANNING BOARD MEETING DATE: June 5, 2003 APPLICANT INFORMATION 1. Name of Business: Sprint Spectrum L. P. Address: 198 Springfield Street, Agawam 2. Owner: Sprint Spectrum L. P. Address: One International Blvd., Suite 800, Mahwah, NJ 07495 Telephone: (201) 684-4000 Fax: (201) 684-4139 3. Engineer: Natcomm, LLC Address: 63-2 North Branford Rd, Branford, CT 06405 Telephone: (203) 488-0580 Fax: (203) 488-8587 PLAN REVIEW Scale: V = 20' Date: November 8, 2002, revised 4/24/03 Title Block (Street Address, Applicant's Name, Address, Scale, Name of Preparer of Plan): O.K. Description of Project: Proposed mounting of a wireless communication antennas on an existing WMECO power stanchion. The addition of the antennas will add 20' to the existing tower. Site Plan Review Page 2 Description of Site: Property owned by WMECO and is the site of an existing sub station. Provision for Traffic Flow: Unchanged. Parking: Not necessary Drainage: See Engineering comments. Public Utilities: See Engineering comments. Landscaping/Screening and Buffers: It is recommended that a visual screen of arborvitae or other evergreens be planted on the side of the enclosure which faces the residential development. Sign Location: Unchanged. Exterior Lighting: Not provided. Rendering or Elevations: O.K. Dumpster Location: N.A. Other Comments or Concerns: See Fire Department requirements (attached). Town of Agawam, f I � 36 Main Street Agawam, Massachusetts 01001-1837 o ` Tel. 413-786-0400 Fax 413-786-9927 � MP w _ June 6, 2003 Daniel J. Finnegan Y Bulkley, Richardon and Gelinas, LLP 1500 Main Street, Suite 2700 P. O. Box 15507 Springfield,MA 01115-5507 Dear Attorney Finnegan: At its duly called meeting held on June 5, 2003, the Agawam Planning Board voted to approve the Site Plan entitled: "Sprint PSC, Wireless Communications Facility, Site No.: CT57XC911A, Agawam, 198 Springfield Street,Agawam,Massachusetts 01001"prepared by Natcomm,LLC and dated November 8, 2002 and revised April 24, 2003 with the following conditions: 1. The Fire Department requirement for an 18' access driveway shall be met unless otherwise specified by the Fire Department. The applicant shall also assess, in consultation with the Fire Department, the need for a turn-around for emergency vehicles. 2. The side(s) of the equipment compound visible from the nearby residence shall be screened by arborvitae or other appropriate vegetation. If you have any questions, please do not hesitate to contact the Planning Office at 786-0400, extension 283. Sincerely, Dennis B. Hopkins, Chairman Agawam Planning Board cc: Clerk Building Engineering Board of Appeals File .0 9 TowNoFAGAwAm INTEROFFICE y � ��ATED Mpy MEMORANDUM To: Planning Board CC: File, Board of Appeals From: Engineering Date: May 15, 2003 Subject: Site Plan 420 - Sprint Spectrum - 198 Springfield Street Per your request dated May 12, 2003, we have reviewed the site plan entitled "Sprint PCS - Wireless Communications Facility - Site No.: CT57XC911A - 198 Springfield Street, Agawam, Massachusetts; Dated: 11/08/02; Rev 4/24/03; Scale: as noted.", and have no comments at this time. If you have any questions, please do not hesitate to contact us. Sincerely, Sincerely, 7s T. Daley, P.E. Michael C. Chase, E.I.T. n Engineer Civil Engineer II H:IENGINEER1sp142.0101.wpd 01 fAgawam Town o ' 36 Main Street Agawam, Massachusetts 01001-1837 O Tel. 413-786-0400 Fax 413-786-9927 ATE MP . MEMO TO:' . Engineering Dept., Police Dept., Xi4ept. FROM: Planning Board DATE: May 12,2003 SUBJECT: Site Plan- Sprint Spectrum- 198 Springfield Street Please review and comment on the attached Site Plan for Sprint Spectrum at 198 Springfield Street prior to the Board's May 15`h meeting, if possible. Thank you. DSD:pre P, Michael R. Mercadante Fire Inspector Agawam Fire pepprtment Date: I G—T • M I VV LVGlJ VJ•J,J rl.lwr• 4Jr r1unwnl"1 !QO 77Cf r.GC AGAWAM PLANNING BOARD Form D Application far Site Plan.Approval Please complete the following form and return it and 10 copies of the Site Plan to: Agawam Planning board Office of Planning and Community Development 36 Main Street Agawam, MA 01001 1. Name cfBusiness Sprint Spectrum L.P. Leasehold Address, 1`?�- s��i e]cLfi�_,Aq pam y_MA Telephone Fax 2. Name of Applicadt/Owner--Sprint Spectrum L.P. Address One International Blvd. , Suite 800 Mahwah Ni 07495 Telephone (201 ) 684-4000 F (201 } ' 3. Nam of Natcomn, LLC ; s Address 63-2 North Branford Rd. , Branford, CT 06405,,. Telephone_, (203) 488-0580 - F (203) 488-8587 4, Please give a brief description of the proposed project: sprint Spectrum L.P. is proposing to mount wireless communications antennas on an existing Western Massachusetts Electric Company ("WMECO") power stanchion with accompanying base station equipment on the ground below, The WMFCO power stanchion is located at 198 SPringfield Street in Agawam. The power stanchion is currently 95 feet in height. Sprint is proposing to add an extension and mount its antennas PO- centerline at the 112 foot level. Further detail can be found in the accoanying plans. Revised 9112100 Mar - 15. 2003 10:03AM B 06 No,7105 P. 212 BULKLEY, RICHARDSON AND GELINAS, LLP LAW OFFICES - ROBERT B ATKINSON Kmm C. MAYNAR6 EL.1%AP6T7W H S;LLIN 15W MAN STREET,SUITE 2700 ROBERT A. GELINAS MARK D CRE59 VANESSA L SMITH VY POST❑FFMF BOR 15507 STEPHEN W SCHUFACK MIARY J KENNEDY OESRA A.QU INN $FR[NUF1EL0. MA 01 1 15-5507 MARTin D TUAp1E J M3CHAEL SCULLY JOSHUA P GREY �wm w.ewn�Bik- ! w.+�.�*.wPETER Rr TH jhMHF C 44VA JENELLF-C DObas SPRINGFIBOSTON TCI_: (4i B17B1+2620 2 RpNALD P WEISF KE t.Lr A. MCCARTHY CHRISTINE Y LE BEL FAX: (d131 272-BB03�{C 4' / FRANCIs 0 0141SL@,JR DAN1@L J FINNEGAN .4NpREW J ORAYER' C-MAIL:INF007BULKLEY.COM HAIdILTON DOHERTY,JR MELINDA M PHEL1'B MICHAEL H I3URKE DESORAH D FERRITER PETER N BARRY JEFFREY E POINDExT£R DAVID A. PARKE KATHERINE A. ROBERTSON COUNSEL FELICITY HARDEE SANORA J $TAUS CAROL E KAmm* CpR1r,TQPHER 9 MVMRUM KAYMLE6N L61TAQ SERNARDO PHILIPJ TARPEY,JR GEORCE W MARION CONN A. RAKDALL'ELLEN M RANMLE SCOTT W FOSTER "Rsr-1vE IT IN 998TON oFFiGE May 15, 2003 Agawam Planrdng Board 36 Main St. Agawam,MA 01001 Re: Sprint Spectr=L.P. Site Plan Review Dear Members of the Board: I am counsel to Sprint Spectrum, L.P. C"Sprinf }. At the direction of the Planning Office, 1 am writing to request that the site plan review of Sprint's proposed wireless communications installation at 1199 Springf eld Street scheduled:for this evening be continued until the Board's next meeting. `I bmk you. Sincerely, Daniel J. Fixuaegan DJF:bak May . 15. 2003 10 : 03AM BR 06 No 7105 P . 1/2 But_ `f, RICHARDSQN AND GELINAS, Io LAW OF7=Ic9115 TEL. (413) 781-2820 1500.MAIN STREET, 5UJTZ 2700 FAX: (413) 272-6803 J9vaweriean eOxroN POST OFFICE BOX 15507 - SPRIN0FIEL,0, MA OI 1 154507 FACS)(M]LE COVER PAGE DATE: May 1.5,2003 TO: Pam Edmunds COMPANY{FMM: Agawam Plan mg Board FACSIMILE#: (4I3) 786-9927 FROM: Daniel J. Finnegan, ICE: Sprint Speeb-a m L.P. Site Plan Review TOTAL NUMBER OF PACES INCLUDING THIS COVER SHEET: 2 MESSAGE: If you experience any difficulty with this transmission or if you do not receive the entire document,Please contact Beth Keene at (413)272-6236. *"*""*****CONFIDENTIALITY NOTICE********** This Fax transmission may contain confidential or privileged information, The [nformation is intended for the individual or entity named on this transmittal cover sheet. Receipt, disclosure, copying, distribution or use of the contents of this transmission by anyone else is prohibited NOTE. IF YOU HAVE RECEIVED THIS FAX IN ERROR, NOTIFY BULKLEY, RICHARDSON AND GELINAS, LLP IMMEDIATELY BY TELEPHONE (COLLECT IF NECESSARY)AT THIS NUMBER. (413) 781-2820 A 0 BULKLEY, RICHARDSON AND GELINAS, LLP Q B G LAW OFFICES ROBERT B.ATKINSON KEVIN C. MAYNARD ELIZABETH H. SILLIN 1500 MAIN STR65T, SUITE 2700 ROBERT A.GELINAS MARK D.CRESS VANESSA L. SMITH POST OFFICE BOX 15507 STEPHEN W. SCHUPAOK MARY J. KENNEDY DEBRA A. QU INN SPRINGFIELD, MA 01 1 1 5-5507 MARTIN D.TURPIE J. MICHAEL SCULLY JOSHUA P.GREY PETER ROTH JAMES C. DUDA JENELLE C. DODDS SPRINGFIELG BOSTON TEL! (413)781-2820 RONALD P.WEiSS KELLY A. MCCARTHY CHRISTINE Y. LE BEL FAX. (413)272-$803 FRANCIS D. DIBBLE,JR. DANIELJ. FINNECAN ANDREW J. DRAYER• E-MAJL; JNFOOBULKLEY.COM HAMJLTOJV DOHERTY,JR. MELINDA M. PHELPS MICHAEL H. BURKE DEBORAH D. FERRITER PETER H. BARRY JEFFREY E. POI NOEXTER DAVID A. PARKE KATHERINE A. ROBERTSON COUNSEL FELICITY HARDEE SAN➢RAJ.STAUB CAROL E. KAMM' CHRISTOPHER 6. MYHRUM KATHLEEN LE1TAO BERNARDO PHILIP J.TARPEY,JR. GEORGE W. MARION ❑ONN A. RANDALL* ELLEN M. RANDLE SCOTT W, FOSTER 'RESIDENT IN BOSTON OFFICE May S, 2003 Attn: Pam Edmunds Agawam Planning Board Office of Planning and Community Development 36 Main St. Agawam, MA 01001 Re: Sprint Spectrum L.P.'s Application for Site Plan Approval Dear Ms. Edmunds: Pursuant to our conversation, I am enclosing Sprint's Application for Site Plan Approval and nine(9) copies of the Addendum to Sprint's Special Permit Application. Please give me a call if you have any questions. Sincerely, Daniel J. Finne an DJF:bak Enclosures st .iqn .•1+ ' S e i3 lwl Town of Agawam 11, 30 36 Main Street Agawam, Massachusetts 01001-1837 0 Mp TeI. 413-786-0400 Fax 413-786-9927 MEMO TO: Engineering Dept., Police Dept., Fire Dept. FROM: Planning Board DATE: May 12, 2003 SUBJECT: Site Plan- Sprint Spectrum- 198 Springfield Street Please review and comment on the attached Site Plan for Sprint Spectrum at 198 Springfield Street prior to the Board's May 15th meeting, if possible. Thank you. DSD:pre MAY-08-2003 05:59 To OF AGAWAM 786 9927 P.02 AGAWAM PLANNING BOARD Form D Application for Site Play Approval Please complete the follawing form and return it and 10 copies of the Site Platy to: Agawam Pluming board Office ofPlatu 4 and Community Development 36 Main Street Agawam, MA 01001 1. Name of Business Sprint Spectrum L.P. Leasehold - Address, 198. i nqf i e7 st_r aQaun ti.-ma 2, Name of ApplicantlOwner Sprint Spectrum L.P. Address One International Blvd. , Suite 800, Mahwah, NJ 07495 4. _ Telephone (201 ) G84-4Qa0 F (201 ) '` tcomm, LLC x. . � '� g e � 3. Name of Engineer/Architect_- Na - -- 63-2 North Branford Rd. , Branford, CI` 0640 .Y e. Address Telephone,. (2Q3) 488-0580 _ � � (203) 488-8587� 4. Please give a brief description of the proposed project: Sprint Spectrum L.P. is proposing to mount wireless communications antennas on an existing Western Massachusetts Electric Company ('NCO") power stanchion with accompanying base station equipment on the ground below. The WMEOa power stanchion is located at 198 SPringfield Street in Agawam. The power stanchion is currently 95 feet in height. Sprint is proposing to add an extension and mount its antennas PO- centerline at the 112 foot level. Further detail can be found in the accoapnying plans. Revised 9/12/00 ! • ADDENDUM TO _ SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION' Section 180-96A(1). A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A_ The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A(2). ,Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180=96A(3). See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B(1). A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report, this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting. Section 180-96B(2). The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B(3). Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway,Mailstop KSOPHT01 01-Z2020, Overland Park, Kansas 66251-2020. Section 180-96B(4). Correspondence or communications concerning the application may be sent to Carla Chaves, Property Specialist, Sprint PCS,Crossroads Corporate Centex, Suite 800, One International Blvd., Mahwah,N.J. 07495. Ms. Chaves's phone number is (201) 684-4079. Section 180-9613(5). Attached hereto as Exhibit F is a copy of a consent from the fee Owner of the property to Sprint's application for a special permit. Section 180-96B(6)_and (7). The requisite plans are being filrpd evv th. r 'OWN OF AGAWA 36 MAIN STREET AGAWAM, MA 01001 a BOARD OF APPEALS M MEMO DATE: May 6, 2003 TO: Planning Board FROM: Board of Appeals RE: Site Plans for: 198 Springfield Street Attached please find 10 copies of the site plan for the above referenced property, These plans are for your review and comments, and any recommendations you may have so we can consider these recommendations and comments in our final decision. If you do not respond to this Board within thirty-five (35) days of the above referenced date, we will assume that you have no objections. 7 I i Y. mAY t 6 2003 123 s Y .�. J, Case # Fred. Appiicatic n to Board of Appeals for 52EC= kERZ411 as provided in the Zouuag and other By-laws. 1 International Blvd. , Suite 300 App,Ucant_p=,nt apu� ,rn L,P_ Addr+essigahwaa NJ 07495 — Application is hereby made for as provided by. Section 180 Paragraph 96 of the By-law. Premises affected axe situated on Springfield - Street; feet distant from the corner of Maple...,.,, _ Street and 1a=ow3n as street number 1gg• Property is ZO%Xed. aS Business B Sipr" S ct P. rggugists a s ial rmit to mount wireless eonmunications antennas on an existing Western Massachusetts Electric OOsnpany power stanchion with e on fine ound below. Further detail and sut)port is con in ed •in the j2lana and.,materials filed herewith. Sprin ct R 7f2 By: iel J. I to ey Si ature of owner o 's authorized agc=nt`;- NOTICE: T •S APPLlCC4'i"rON MUST BE F7ZLED"4]UZ' rN BW<�0R'TIF,EWRrZTZV ADDENDUM TO SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION' Section 180-96A(1). A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A. The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A(2). Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180-96A(3). See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B(1). A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report,this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting. Section 180-96B(2). The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B(3). Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway, Mailstop KSOPHT0101-Z2020, Overland Park, Kansas 66251-2020. Section 180-96B(4). Correspondence or communications concerning the application may be sent to Carla Chaves, Property Specialist, Sprint PCS, Crossroads Corporate Center, Suite 800, One International Blvd., Mahwah,N.J. 07495. Ms. Chaves's phone number is (201) 684-4079. Section 180-96B(5). Attached hereto as Exhibit F is a copy of a consent from the fee Owner of the property to Sprint's application for a special permit. Section 180-96B 6 and (7). The requisite plans are being filed herewith. ADDENDUM TO SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION Section 180-96A(1). A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A. The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A(2). Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180-96A(3). See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B 1 . A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report, this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting. Section 180-96B 2 . The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B 3 . Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway, Mailstop KSOPHT0101-Z2020, Overland Park, Kansas 66251-2020. Section 180-96B 4 . Correspondence or communications concerning the application may be sent to Carla Chaves, Property Specialist, Sprint PCS, Crossroads Corporate Center, Suite 800, One International Blvd., Mahwah, N.J. 07495. Ms. Chaves's phone number is (201) 684-4079, Section 180-96B 5 . Attached hereto as Exhibit F is a copy of a consent from the fee Owner of the property to Sprint's application for a special permit. Section 180-96B 6 and 7 The requisite plans are being filedle er -W1-.- 4-N p`� ADDENDUM TO SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION" Section_180-96A(1). A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A. The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A{2). Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180-96A 3 - See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B 1 . A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report, this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting. Section 180-9613Q. The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B(3). Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway,Mailstop KSOPHT0101-Z2020, Overland Park, Kansas 66251-2020. Section 180-96B(4). Correspondence or conu unications concerning the application may be sent to Carla Chaves, Property Specialist, Sprint PCS, Crossroads Corporate Center, Suite 800, One International Blvd., Mahwah, N.J. 07495. Ms. Chaves's phone number is (201) 684-4079. Section 180-96B(5). Attached hereto as Exhibit 1~ is a copy of a consent from Owner of the property to Sprint's application for a special permit. *' Section 180-96B(6) and (7). The requisite plans are being filed h ADDENDUM TO SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION' Section 180-96A 1 . A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A. The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A 2 . Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180-96A 3 . See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B(1). A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report, this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting. Section 180-96B(2). The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B . Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway, Mailstop KSOPHT01 01-Z2020, Overland Park, Kansas 66251-2020. Section 180-96B(41. Correspondence or communications concerning the application may be sent to Carla Chaves, Property Specialist, Sprint PCS, Crossroads Corporate Center, Suite 800, One International Blvd., Mahwah, N.J. 07495. Ms. Chaves's phone number is (201) 684-4079. Section 180-96B(5). Attached hereto as Exhibit F is a copy of consent fromth--flee Owner of the property to Sprint's application for a special permit. Section 180-96B(6) and (7). The requisite plans are being filed hei i rit}i.' TV 4. d ADDENDUM TO _ SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION- Section 180-96A(1). A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A. The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A(2). Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180-96A(3). See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B(1). A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report, this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting. Section 180-96B 2 . The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B(3). Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway, Mailstop KS OPHTO 10 1-Z2 020, Overland Park, Kansas 66251-2020. Section 180-96B 4 . Correspondence or communications concerning the application may be sent to Carla Chaves,Property Specialist, Sprint PCS, Crossroads Corporate Center, Suite 800, One International Blvd.,Mahwah, N.J. 07495. Ms. Chaves's phone number is (201) 684-4079. Section 180-96B(Q. Attached hereto as Exhibit F is a copy of a consent from the fee. Owner of the property to Sprint's application for a special permit. ,Section 180-96B(6) and (7). The requisite plans are being filed her 1.Z.- CA ��� ADDENDUM TO SPRINT SPECTRUM L.P.'s SPECIAL PERMIT APPLCIATION Section 180-96A(1). A complete listing of the facility sites in which Sprint has a legal or equitable interest either in Agawam or within eight miles of Agawam is attached hereto as Exhibit A. The site specific information required by this section is also included in Exhibit A. A discussion as to why Sprint cannot make adjustments to these facilities to provide the necessary coverage is contained in the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96A(2). Sprint has examined existing facility and tower sites located in Agawam in which Sprint does not have a legal or equitable interest. Among the sites reviewed was the existing Western Massachusetts Electric power stanchions on which Sprint now seeks to locate its antennas. This site will allow Sprint to provide its customers in this area of Agawam with the required coverage without having to construct a new tower. Section 180-96A(3). See the statement of Sprint's radio frequency engineer attached hereto as Exhibit B. Section 180-96B(1). A copy of Sprint's FCC license is attached hereto as Exhibit C. A copy of a report prepared by Sprint's FAA consultant is attached hereto as Exhibit D. As stated in that report, this facility will not require that a Notice of Proposed Construction or Alteration form be filed or that formal FAA approval be obtained with respect to the proposed project. Nor will the power stanchion require any marking or lighting_ Section 180-96B(2). The Massachusetts Department of Public Health no longer requires this filing. A Power Density Analysis Report comparing the proposed site's effective radiated power to radio frequency exposure guidelines has been attached hereto as Exhibit E. Section 180-96B(3). Sprint Spectrum, L.P. is a Delaware Limited Partnership with a principal place of business at 6391 Sprint Parkway, Mailstop KSOPHT0101-Z2020, Overland Park, Kansas 66251-2020. Section 180-96B(4). Correspondence or communications concerning the application may be sent to Carla Chaves,Property Specialist, Sprint PCS, Crossroads Corporate Center, Suite 800, One International Blvd., Mahwah, N.J. 07495. Ms. Chaves's phone number is (201) 684-4079. Section 180-96B(5). Attached hereto as Exhibit F is a copy of a consent from the fee Owner of the property to Sprint's application for a special permit. y Section 180-96B(6) and (7). The requisite plans are being filed he t R CO f,I t V) WIR MMUN AT N FA I I Y ", SIT No . T57XC91 1 A C) _ N •cn PROJECT SUMMARY GENERAL NOTES TOPOGRAPHY MAP A No ,000 2( IN FEET +0, _©•„ �� � „iN APPROVAL' NRTH ��+�.y, SITE NAME: AGAWAM L�►N ppppp({{( ppy}u/�1 O t •€' 1 ZeL -K¢ Y `i 7SM1 ,r,,{ { -- - V.) - � F tli td . �'+' i V i �- il/ SITE NUMBER: CT57XC911A 1. THE SCOPE OF WORK TO INCLUDE CONSTRUCTION OF A 10 FT. X 24 FT. WIRELESS -_ SITE ADDRESS. 198 SPRINGFIELD STREET COMMUNICATIONS FACILITY COMPOUND. THE COMPOUND WILL CONSIST OF THREE 3 ..... r$ , *H��i(,-, 4 - AGAWAM. MASSACHUSETTS DIRECTIONAL PANEL ANTENNAS, MOUNTED TO AN EXISTING TRANSMISSION TOWER, �� ' z AND A 18'-0" X 9`-6'° CONCRETE PAD WITH PC5 EQUIPMENT. xn � � r ` > PROPERTY OWNER: WESTERN MASSACHUSETTS ELECTRIC COMPANY z t i'9P ' M.A. 174 BRUSH HILL AVE 2. THIS WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR PERMANENTSjx x f iLJ) oz WEST SPRINGFIELD, MA 01089 OCCUPANCY AND THEREFORE DOES NOT REQUIRE POTABLE WATER, SANITARY _ ( M ' SEWERS AND ADDITIONAL SITE PARKING. , TENANT: SPRINT SPECTRUM LP 1 INTERNATIONAL BLVD.—SUITE 300 3. THIS FACILITY SHALL BE VISITED ON THE AVERAGE OF ONCE A MONTH FOR MAHWAH, NJ 07495 PERIODIC MAINTAINENCE. r PROJECT y i Y -; LOCATION 4. ELECTRICAL AND TELCO SERVICES WILL BE RUN UNDERGROUND TO THE COMPOUND FROM THE EXISTING UTILITY POLE FINAL APPROVALS M , .� {.. v t CENTER OF TOWER: LATITUDE: 42' 05' 29,004'° , � � WILL BE REQUIRED FROM THE RESPECTIVE UTILITIES. 4 , '• ,)- LONGITUDE: 77 38' 07.67" 4 5 ICY 0, � •K' V �� ^0 fi ?1, $ + f Wt•. r�{�(�/} GROUND ELEVATION: 173't AMSL 5. NO SIGNS OR LIGHTING SHALL BE ADDED UNLESS REQUIRED BY FAA AND FCC. ' �, � •?�.� '�` fit:` ���, �. �� Via' 4 �� �� ��� 6. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN j i� _ i' �..; <h ^ ... ': O tA� �" ACCORDANCE WITH THE APPLICABLE SECTIONS OF SPRINT SPECTRUM (SSLP) wY i ti�w r�'$� ,� ; $ 4X0'- -. �tv m '.4 cb" � S� •� STANDARD CONSTRUCTION SPECIFICATIONS IN CASE OF A CONFLICT BETWEEN S `� `° '` ''' {{ THE CONSTRUCTION SPECIFICATIONS AND THE DRAWINGS, THE DRAWINGS SHALL k,Y�s sxYkY K fig. € GOVERN. IN CASE OF A CONFLICT BETWEEN SSLP STANDARD PRACTICES ANDs ;,t "' q SITE DIRECTIONS EITHER THE CONSTRUCTION SPECIFICATIONS OR THE DRAWINGS, THE SSLPt STANDARD PRACTICES SHALL GOVERN. t „ - a 4` �r Y ' Y ' r� f { i J W A t i S ar s4F?F' <`s' * K: �{'K�a ¢ r i � 4 '' _ SOUTHEAST C CROSSROADS ,., . _ _- - --- -- - -- -- - - ' F�} ; y i iiry: f ; 4 �l�EEI' INDEX GO SOUTH€AST ON QU€€NSLAND BD. TOWARD CROSSROADS BLVD. TURN RIGHT 7, THE 9RUCTURE SMALL BE 6EsicNEb TO MEET THE REQUIREMENTS of THE �� ONTO CROSSROADS BLVD. TURN LEFT ONTO LEISURE LN. MERGE ONTO NJ-17 -A ANSI T1A/EIA 222—F (JUNE 1996) TITLED STRUCTURAL STANDARDS FOR STEEL ,a, , '• ,�; �,,. i, 5; -.,�,. r�•,� �: N. NJ-17N BECOMES 1-287 N/NJ-17 N. MERGE ONTO NEW YORK STATE TRWY ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES. IT SHALL ALSO { SHT. NO. DESCRIPTION REV. S/I-87 TOWARDS TAPPAN ZEE BR/NEW YORK CITY. MERGE ONTO 1-287 MEET OR EXCEED THE REQUIREMENTS OF THE BOCA NATIONAL BUILDING CODE, f { °, iM. .v . AM E/CROSS WESTCHESTER EXWY VIA EXIT #8 TOWARDS WHITE PLAINS. MERGE AND THE MANUAL OF STEEL CONSTRUCTION ASD NINTH EDITION BY THE F it � i r ` xx _ T-1 TITLE SHEET 1 ONTO 1-95 N. MERGE ONTO 1-91 N VIA EXIT #48 ON THE LEFT TOWARD AMERICAN INSTITUTE OF STEEL CONSTRUCTION. FURTHERMORE, THE FOUNDATION .. HARTFORD. TAKE THE US-5 EXIT #3 TOWARDS AGAWAM/WEST SPRINGFIELD. AND ANCHOR BOLTS MEET THE REQUIREMENTS FOR STRUCTURAL CONCRETE `` ,� '}_ '` C-1 SITE PLAN 1 ti.:4 \ 3g'4F`GC'Y ' } MERGE ONTO US-5. ENTER NEXT ROUNDABOUT AND TAKE 3RD EXIT ONTO (ACI 318-95). THE POLE STRUCTURE SHALL BE DESIGNED TO MEET THE MA-57 WEST. TURN SLIGHT RIGHT ONTO MA-159/MAIN ST. MA-159/MAIN ST. PROVISIONS OF THE AMERICAN SOCIETY OF CIVIL ENGINEERS (A.S.C.E.) DESIGN { x { � ' n<fz �> K C-2 COMPOUND PLAN AND TOWER ELEVATION 1 OF STEEL TRANSMISSION POLE STRUCTURES WHICH WAS ORIGINALLY PUBLISHED f ai "fs BECOMES MA-147/SPRINGFIELD ST. TOTAL ESTIMATED TIME: 2 HRS, 27 MIN. <� t. DISTANCE 145.E MILES IN 1973 AND MOST RECENTLY UPDATED IN 1990. 4 ' ' { A � Yt ' � � F :� #w ' C-3 SITE DETAILS AND NOTES 1 f 4 C-4 EROSION CONTOL DETAILS AND NOTES 1 d n 0 th m 3 N 0. 3 lNatcomm,LLC•Enginesrrng Cmsullants • Natcomm, LLC Martinez - :r .. • f Sp�tnt Spectrum 3 Couch 464 Washington Avenue AGAWAMSprint ,f ;;:;3,.<r, ;;f 63-2 North Branford Road North Haven, Connecticut 06473 LP Branford, Connecticut 06405 � o , ;:.::• & Tel (203) 985-9012 M SPRINGREL.D ST Q d . :F;.,:F< , ..; Tfl'LE SHE :{ 3 Q Q1 04/24/03 ISSUED FOR FINAL ZONING P.A.M. JJP CFC ""' '. m u.,...f Tel. (203)488-0580 Associates Fax (203) 985-9064 AGAWAM MASSACHUSETTS 01M ' ' ND Fax(203)488-8587 Email: email@martinezcouch.com I International Blvd.,--,Suite uite Soo ® 01/24/03 ISSUED FOR PRELIMINARY ZONING REVIEW P.A.M. JJP CFC ' ��' LLC STI= \� %f' ro'ect Management At-- JOB NO. DRAWING NUMBER REV. Mahwah NJ 0 7495' N°- DATE REVISIONS BY CHK APPv. 0 o =.; �.:{ . �,;G .r Consulting Engineers•P t g � �' :�T��w ' rin t 134!7J ! IT ESS CO Ic 10 S C AGAWAM 198 SPRINGFIELD STREET AGAWAM MASSACHUSETTS 01001 ...':•.:=��•.=�: Civil•Structural•Mechanical•Electrical 9 ■ stuegnswoOupaauOU3-0„'w—cWN■ Land Surveyors, Engineers, Environmental Consultants PROFESSIONAL ENGINEER SEAL 02 A.M.DRAWN BY: P CHECKED BY: JJP SCALE: AS NOTED DATE: 11 08 / / 02619 T-1 1 SURVEY NOTES N MARY E. & CARMEN A. AVERSA 158 MAPLE STREET N/F 14'42' VOL 6262 P. 437 1 THE PROPERTY/BOUNDARY LINES DEPICTED HEREON ARE COMPILED FROM OTHER MAPS, DANIEL R, BRADY & DEEDS AND LIMITED FIELD SURVEY. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT NICOLE M. LA PALME 0-45046N OF AN UP TO DATE ABSTRACT OF TITLE OR TITLE REPORT AND IS SUBJECT TO ANY MON 147-149 MAPLE STREET STATEMENT OF FACT SAID REPORT MAY REVEAL [� (FD) VOL 10465 P. 388 Z VERTICAL DATUM IS BASED ON NGVD 29 N/F :3 COORDINATES REFER TO NAD 83 AND ARE BASED ON G.P.S. SURVEY AND REFER TO THE N/F JAMES S. 7 SUSAN L MASSACHUSETTS STATE PLANE, MAINLAND ZONE, US FOOT. HAES WESTERN MASS. • \ N/F N/F 49 PRO PECT STREET ELECTRIC CO. / JANICE ANN & WAYNE A. & ANGELA VOL 7050 P. 215 THE INTENTION OF THIS MAP IS TO SHOW THE LOCATION OF THE WIRELESS M.A. T BRUSH HILL AVE. ` RdBERT D. M. /� COMMUNICATIONS FACILITY TO BE CONSTRUCTED BY SPRINT PCS. WEST SPRINGFIELD, MA V \` SPECDEFIL PI MAJKA PARCEL OWNER OF RECORD: WESTERN MASS. ELECTRIC COMPANY Q 24 PROSPECT STREET 30 PROSPECT O M.A. 174 BRUSH HILL. AVE. 3� VOL. 6056 P. 90 STREET /• \ �^ VOL 10510 P. 16J CP �v /y o WEST SPRINGFIELD, MA 01089 PARCEL LOCATION: 198 SPRINGFIELD STREET 8 PARCEL MAP 115 BLOCK 7 LOT 1 AGAWAM ASSESSORS MAP. S �' � '�� � S� a • NOT ALL IMPROVEMENTS ARE SHOWN, MO 3�99� \ ` 4 PARCEL AREA m+ 21f ACRES. (FD �� N/F ` PROPOSED PR P TH M. BOTTARO PARCEL IS IN THE BB ZONE. p � � O \ q�E0 25' ACCESS & 228 WALNUT UTILITY EASEMENT STREET AREA•-9.696 SO. FT. -1 JAMES N JAMES R. &SANDRA S. VOL 11151 P.� PROPOSED 1 12' ACCESS DRIVE \ HARTNETT /\ 35 WINTHROP STREETloe rQ4 \ t / ,�� \ ` VOL 4829 P. 311 SHIRLEY F. LOMBARD & V k \ TH ERESA A. STRAIN �� / ! M.A. 232 WALNUT STREET •60, VOL 8716 P. 493 Effuk= ROY E.N EB iJAMIN �` \ �` • _ �1 J X �� 175•--177 MAPLE STREET ��� � �� `� 'IA PROPOSED EROSIO ONTROL Z'-N�(b M.A. 49 ORIOLE \ �. hs FEEDING HILLS, MA 01030 ` VOL 10803 P. 174 �0 ON r N7013'26"E 4e` /k 5.00 PROPOSED SPRINT 10' X 24' WIRELESS COMMUNICATIONS \ / N/F .gyp FENCED COMPOUND O• / JOS11M TH SWSTRAIN N1 4"W \ GSTREET RID N:2860379.020 k \ VOLW 0ALNUT 882 P. 526 _C cn \ GRID E:347986.651 SYMBOLS LEGEND �Ar k -\�� �, LATITUDE: 42.05'29,004" Y HIGH VOLTAGE POLE STONE WALL o� LONGITUDE: -72 3 . . .673 L 1 ;�. a x cam GROUND =173.0' AMS. � t � OO MANHOLE X FENCE LINE TOP OF POLE=97.0' A.G.L. u 4 UTILITY POLE -- — PROPERTY LINE d CD >--- GUY ANCHOR - -- EASEMENT LINE v ��' 7, cRp : ri o POST �� TREE LINE ) r M�RkF� 1 / k N/F SETTA A. MCCABE 252 WALNUT STREET N/F VOL 6862 P. 392 SUTTON PLACE LLC' 191 MAPLE STREET U5 M.A. 131 ASHLEY AVE. CL SUITE A-1 WEST SPRINGFIELD, MA 01089 VOL 10566 P. 275 / N/F THOMAS R. FREDETTE 266 WALNUT STREET VOL 9100 P. 75 1 / EXISTING SUB STATION k (PER ASSESSORS MAP) GRAPHIC SCALE 4 IN FM ' o 1 inch = 60 it / k � N/F WORTH FINACIAL GROUP LLC M.A. 155 DUNSTABLE ROAD NASHUA, NH 03060 VOL 10372 P. 475 ` � x 1 SITE PLAN C-- SCALE: 1 = 60 -0 N/F SPRINGFIELD GAS N/F LIGHT CO. x / WESTERN MASS. M.A. FRIBH, MA 41581 ELECTRIC CO. TBO PARKWAY /M.A. 174 BRUSH HILL VE. WE VOL 9424 N/F t x WEST SPRINGFIELD, A � VOL 424 P. 312 NORMAN F. & SOPHIE F. � VOL 4365 P. 74 N ?�3yty�, \ JASMIN ` 82SPRINGFIELD 5�T STUART A. JR. & VOL 2746 P. 11 / SHIRLEY A. KIBBE / 160 SPRINGFIELD STREET VOL 6987 P. 124 I *CERTIFY THAT THIS SURVEY AND PLAN CONFORM TO THE PROCEDURAL AND — TECHNICAL STANDARDS FOR THE PRACTICE OF LAND SURVEYING IN THE — 196.0$' S8.07' — COMMONWEALTH OF MASSACHUSETTS AND CONFORM WITH THE RULES AND REGULATIONS OF THE REGISTRY OF DEEDS OF THE COMMONWEALTH OF MASSACHUSETTS. SPRINGFIELD STREET *NOTE: THE WORD "CERTIFY" IS UNDERSTOOD TO BE AN EXPRESSION OF 0 PROFESSIONAL OPINION BY THE LAND SURVEYOR WHICH IS BASED ON HIS BEST KNOWLEDGE, INFORMATION, AND BELIEF, AS SUCH, IT CONSTITUTES N NEITHER A GUARANTY NOR WARRANTY. ANTH N�MANZI L UISE, BE T & �1 G W AM BRO GI T & DA D MASON [ ' ' / N M.A. 35 ARLENE DR. 1 SPRINGF) N _y/ZY�D TENNESEE GAS PIPELINE 0. M.A. 35 E 0103R. STREW RACING F LLC C/0 P.O. BOX 2511 VOL 9 59 P. 70 OL 6911 27 M.A. 16 EAST MAIN STREET N/� N/F ! OGEE lulA PLS #35759 DATE HOUSTON, TX 77252 N/F WESTBOROUGH MA 02474 ! n VOL 2334 P. 113 D VID J. MASO JR. VOL 12337 P. 160 V f NIRVANA MANAGEMENT FRANKLIN REALTY COMPANY LLP. NOT VALID UNLESS SEAL AFFIXED HEREON 3 SPRINGFI LD M.A. MAIL STATION #1120 M.A. 95 STATE STREET STREET ROCKY HILL, CT 06067 SPRINGFIELD, MA 01103 VO 12139 P. 48 VOL 4855 P. 351 VOL 11275 P. 561 ■Natcomm,LLC•Enginaedng CmsuHanls • Natcomm LLC Martinez _ % '= f - 464 Washington Avenue • Fp,�q� Sprint Spectrum LP `F={; = 63-2 North Branford Road Couch North Haven, Connecticut 06473 AGAWAMSprin j .. {. ,{: t LP o f.,., � Branford, Connecticut 06405 � C N�� Q ^r cri /.vv E m 8 SPRINGRELD Tel (203) 985-9012 1 04 24 03 ISSUED FOR FINAL ZONING .A.M. JJP S i 6�110EN Tel. 203 488-0580 Assoe�ates ( • • Q / / P CFC c ) Fax 203 985-9064 AGAWAM, MASSACHUSETM OW 4 b w l International Blvd.,-,Suite 300 Fax{203)488-8587 Email: email®martinezcouch.com • ® 01/24/03 ISSUED FOR PRELIMINARY ZONING REVIEW P.A.M. JJP CFC �n Consulting Engineers-Project Management fQ , F ff' J--I----- yFJJv Mahwah, NJ 07495 NO. DATE REVISIONS BY CHK APPV. JOB NO. DRAWING NUMBER REV. Z :��z=��r� Civil Q�'�� ��/� M�y�w 0 slue�nauoa 8uuaaw6u3•0ll'wwoOeN 0 �1 1�i. I�V� 'V 1 V/AWIIM Land Surveyors, Engineers, Environmental Consultants DRAWN BY: P.A.M. CHECKED BY: JJP SCALE: AS NOTED DATE: 11/08/02 PROFESSIONAL ENGINEER SEAL 02619 C-1 1 18'-0" © VALMONT TRI-SECTOR STANDOFF CHAIN MOUNT `t TRUE PRODUCT NUMBER B16622 NORTH WITH THREE ANTENNA SECTOR ADAPTER to PRODUCT NUMBER B2052 1 340' MODCELL MODCELL SECTOR 1 AVAYA AVAYA : p 3.0 3.0 60ECv2 60ECv2 B GROWTH PRIMARY BATERY BATERY RADIO RADIO 8"0 SCHEDULE 80 PIPE .. _.___.. RR65-19--OODP ANTENNAS N (TYPICAL)239 SECTOR 3 \ Ft PLAN A y 15V SECTOR 2 35" rT 4 ANTENNA MOUNTING CONROURAMN L'—� NOT Tn CCAI_E ie I 10 in 115'-0"f ABOVE BASE PLATE ELEVATION "A" ELEVATION "BA 112'-a"f ABOVE BASE PLATE M©�► RAD CENTER FOR SPRINT PCS r3""� ORTHOGRAPHIC EQUIPMENT PI A N PANEL ANTENNAS C—2 NOT TO SCALE !_I"1 95'-0"f ABOVE BASE PLATE _ _ _ TOP OF EXISTING UTILITY POLE I k i 2 f 1 UTILITYSED POLES,EXTENSION EXISTING UTILITY O I POLE X iPROPOSED EROSION / � CONTROL I EXISTING UTILITY POLE z I PROPOSED GRAVEL / 1 i A- (LN#1314) w I TURN AROUND � f � PROPOSED 12' WIDE \ ♦ / I PROPOSED ELECTRICAL AND \ ACCESS DRIVE ����\ �\ } TELCO SUPPORT FRAME \` , PROPOSED 25' I PROPOSED UTILITY I TRANSFORMER AND ACCESS/EASEMENT '� ` \ / ` ♦ I ELECTRICAL AND TELCO \ \ VO MAPLE STREET „� • SUPPORT FRAME \ 1 LEASE AREA PROPOSED 1 -O" X 24i-0" • , . •-` ,� PROPOSED SPRINT PCS o z . ♦ GPS ANTENNA in o ` " (EL. 16 -0 t AGL} PROPOSED SPRINT PCS PPC \ :: CABINET. OFF WHITE FINISH. \� \ PROPOSED SPRINT PCS ` `� \ / \ • 10 -0 X 24 -fi HIGH PROPOSED SPRINT PCS GALVANIZED CHAINLINK FENCE ICE BRIDGE & POSTS 0 // \� WITH 3' WIDE GATE PROPOSED 6" CRUSHED STONE SURFACE WITH STABILIZATION \ 1 I FABRIC PROPOSED SPRINT PCS � \ PAD MOUNTED EQUIPMENT EXISTING PAVED DRIVE � \ PROPOSED SPRINT PCS 18'-0" X 9'-6" PAD MOUNTED EQUIPMENT PROPOSED SPRINT PCS EXISTING PROPERI=T1' LINE �� / PROPOSED SPRINT PCS ICE 6' HIGH CHAINLINK FENCE BRIDGE AND ICE BRIDGE POSTS TYPICAL PROPOSED 6" PIPE BOLLARDS TYPICAL / \ / EXISTING HIGH VOLTAGE o POLE # LN-1314 0 PROPOSED UTILITY PAD MOUNTED TRANSFORMER 1/ /'` \�\ 1 / � / 2 TOWER ELEVATION / EXISTING FENCE �-2 SCALE: 1" = 10'-0" COMPOUND N �-2 - CV U 3 v N a p i .Natcomm.LLC•Eng�neenrtg ConsullanSs • Natcomm LLC p F Sprint Spectrum L { AGAWAM i f G 63-2 North Branford Road Sprin t Spectrum LPp2'. Branford, Connecticut 06405- m c a , Q Y 198 SPRINGRELD ST -� PLAN AM 4 {t }' E m Tel. (203)488-0580 a 1p 04/24/03 ISSUED FOR F1NAL ZONING P.A.M. JJP CFC 4B W .m AGAWAM MASSACHUSETTS 01001 o J : ;;; {.;s, ,f:,ks Fax(203)488-8587 } l International Blvd ^,Sulte 300 4^ `� TOWER ELEVATION • ® 01/24/03 ISSUED FOR PRELIMINARY ZONING REVIEW P A.M. JJP CFC n STF =rFr" `�'� DRAWING NUMBER REV. A �r��f y ;{;,f;;;;y:F:{:,:{:,, � Consulting Engineers-Project Management 1►1� � 1Vlahwah, NJ o 7495 N0. DATE REVISIONS BY CHIC APPv. � JOB N0. a Z ,., f.%%% # ? Civil•Structural•Mechanical•Electrical UM NO. : �XC�Irr1 «a ■ sjugnsuoo 6W120U!6U3.0�1'ww031ery 0 DRAWN BY: P.A.M. CHECKED BY: JJP SCALE: AS NOTED DATE: 11/08/02 PROFESSIONAL. ENGINffR SEAL 02619 C-2 SR'E WORK GENERAL NOTES GATE POST ROADWAY 1. ,THE CONTRACTOR SHALL CALL " DIG SAFE" 0 1-888-344-7233 DOUBLE SWING GATE - CLR OPNG PRIOR TO THE START OF CONSTRUCTION. WIDTH VARIES SEE PLANS CONCRETE CAP 2. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES CHAINLINK FENCE. WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, AND TOP BARBED 6" 0 SCHEDULE 40 CARBON WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED TENSION WIRE WIRE STEEL PIPE ASTM A 53 LIMITS OF CRUSHED STONE AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE FILLED WITH CONCRETE AND SURFACE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. BRACE L PAINT YELLOW. . CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. AT E 1/4"/FOOT WASH " " THIS SHALL INCLUDE BUT NOT LIMITED TO: STRETCHER PROVIDE (TYPICAL) ¢ 2 X 6 PRESSURE TREATED A FALL PROTECTION BAR —�\ INTERMEDIATE w 6 THICK CRUSHED STONE WOOD CURB. B CONFINED SPACE " = SURFACE ON STABILIZATION C ELECTRICAL SAFETY RAILS FOR GATE 1/2 R I FABRIC. DIAGONAL ROD OVER 20'-0" OF i� z D TRENCHING AND EXCAVATION. GRADE TO DRAIN AWAY FROM W/STEEL TOTAL WIDTH GRADE TO DRAIN AS SHOWN ON TOWER YARD. 3. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS. TURNBUCKLE FINISHED GRADE PLAN GATE FRAME FORK LATCH -I I I I l I 1 I I I I I 2" X 4" X 1'-6" LONG 4. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE FINISH GRADE WITH LOCK OR GROUND I=1 I I =1 PRESERVATIVE PRESSURE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. TREATED WOOD STAKE AT CAST-IN-PLACE CLASS A I o " 5. THE SITE SHALL. BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE PCS Li 1/2" CONCRETE FOOTING I 5 -0 O.C. EQUIPMENT AND TOWER AREAS. {MAX} MARAFI STABILIZATION FABRIC 6 MATERIALS,NO FILL SNOW OR ICE HAL EMBANKMENT L NOT BE PLACED IIAL SHALL BE N ANY FILL ORD ON N EMBANKMENT. ROZEN 1 WOVEN WIRE SWING GATE-DOUBLE CRUSHED STONE BASE PLACED ON COMPACTED Z NOT TO SCALE —� SUBGRADE. 7. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR C-3 1 r�o" TO nNi r ica OURPACC APPUCATKW. cQ t =i TOP STRAND 8. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH q 10'-O" OF BARBED WIRE INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, C-3 MAXIMUM PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH 0 1'-O" MIN THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF THE ENGINEER. 9. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, FERTILIZED, 3 STRANDS TOP SEEDED AND COVERED WITH MULCH. BARBED WIRE RAIL ( 2 BOLLARD DETAIL 3 COMPOUND SURFACING DETAIL 10. DISTURBANCE SHALL BE LIMITED TO THE AREA NECESSARY TO CONSTRUCT THE PROPOSED EXTERIOR FACILITY SIDE ACCESS, UTILITIES, EQUIPMENT INSTALLATION AND FENCING. BOTTOM LINE POST, C-3 NOT TO SCALE �-3NOT TO SCALE 11. NATURAL VEGETATION AND TERRAIN SHALL NOT BE DISTURBED BEYOND THE LIMITS OF TENSION WIRE REQUIRED CONSTRUCTION. A DETAIL 12. ALL CONTROL MEASURES SHALL BE PROPERLY MAINTAINED EFFECTIVE CONDITION e b- C-3 THROUGHOUT ESTABLISHER. THE CONSTRUCTION PERIOD AND UNTIL PERMANENT VEGETATION COVER HAS BEEN 13. HAY BALES OR FILTER FABRIC FENCE SHALL BE INSTALLED ALONG THE TOE OF ALL CRITICAL TYPICAL CUT AND FILL SLOPES, AND WHERE SHOWN ON DRAWINGS. ELEVATION 14. GRADING SHALL NOT BE DONE IN SUCH A MANNER SO AS TO DIVERT WATER ON TO ADJACENT PROPERTY WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE LANDOWNER. V_ CORNER, GATE, 15. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REINSTALLED DURING THE o END OR PULL POST BARBEDWIRE CONSTRUCTION PERIOD IF DEEMED NECESSARY OR REQUIRED BY THE TOWN ENGINEER. I TOP AS SHOWN ON _ BRACE RAIL SITE PLAN ROAD OR 0 Z Z 710 STRETCHER 6"DEEP 1"ANGULAR GRAY PAVE AREA Ce BAR CRUSHED STONE oZ¢ DIAGONAL ROD W/ =�`' STEEL TURNBUCKLE "co u z -- ROUGH GRADE v TE S100N WIRE FILL PER THIS DETAIL CROWN c;:p FINISH GRADE CUT OR GROUND 2% 2% �-~t � EXIST GRADE CD Iz 1 1/2" MAX M - CLEARANCE 1-1/2 rn FROM GRADE 1 GEOTEXTILE MIRAFI 60OX OR 4 EXTEND 6" GRAVEL EQUAL SURFACE 1'-0" (1'-0" MIN) BEYOND FENCED COMPOUND. a SCARIFY AND COMPACT TOP 6" TYPICAL SECTION OF EXISTING GRADE BENCHING REQ'D IF NATURAL NOTE: SEE WOVEN WIRE FENCE NOTES THIS DWG. FOR ADDITIONAL INFO. SLOPE IS STEEPER THAN 4:1 4 WOVEN WIRE FENCE DETAIL 5 ACCESS DRIVE �-3 NOT TO SCALE C-3 NOT TO SCALE WOVEN WIRE FENCE NOTES 1. GATE POST, CORNER, TERMINAL OR PULL POST 2 1/2" 0 SCHEDULE 40 FOR GATE WIDTHS UP THRU 6 FEET OR 12 FEET FOR DOUBLE SWING GATE PER ASTM-F1083. 2. LINE POST: 2" 0 SCHEDULE 40 PIPE PER ASTM-F1083. 3. GATE FRAME: 1 1/2" 0 SCHEDULE 40 PIPE PER ASTM-F1083. 4. TOP RAIL & BRACE RAIL- 1 1/2" 0 SCHEDULE 40 PIPE PER ASTM-F1083. 5• FABRIC: 12 GA. CORE WIRE SIZE 2" MESH, CONFORMING TO ASTM-A392. 6. TIE WIRE: MINIMUM 11 GA. GALVANIZED STEEL AT POSTS AND RAILS A SINGLE WRAP OF FABRIC TIE AND AT TENSION WIRE BY HOG RINGS SPACED MAX 24" INTERVALS. 7. TENSION WIRE: 7 GA. GALVANIZED STEEL. 8• BARBED WIRE: DOUBLE STRAND 12-1/2" O.D. TWISTED WIRE TO MATCH W/FABRIC 14 GA., 4 PT. s BARBS SPACED ON APPROXIMATELY 5" CENTERS. 9. GATE LATCH: DROP DOWN LOCKABLE FORK LATCH AND LOCK, KEYED ALIKE FOR ALL SITES IN A GIVEN MIA. 10. LOCAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENT SHALL BE COMPLIED WITH IF REQUIRED. 11. HEIGHT = 6' VERTICAL + 1' BARBED WIRE VERTICAL DIMENSION. N a rn Q S ■Natcomm,LLC•Engineering ConsuHants ■ Na#Comm LLC � • o s ! o o print Spectrum LP 63-2 North Branford Road AGAWAMiprint �f�4l --• S ec �ujn LP o Branford, Connecticut 06405 } 198 SPRiNGFfELD ST D t e 9M C ETALS 04/24/03 ISSUED FOR FINAL ZONING P.A.M. JJP CFC ny Tel. (203)488-0580 AGAWAM MASSACHUSETTS 01001 ' ` `'` ;n: Fax(203)488-8587 l International Blvd �Suxte 300 ® , , :� . ,. n f f }<; • 01 24 03 ISSUED FOR PRELIMINARY ZONING REVIEW P.A.M. JJP CFC a f'r> ;x f s r AND NOTO Consulting Engineers•Project Management NO. DATE REVISIONS BY CHK APPV. � �`' 0! - r` JOB NO. DRAWING NUMBER REV. o %`' Civil Structural.Mechanical, SITE NO, :CT57XC9ttA Mahwah NJ 0 7495 ,y ■ slue{Msuo'j Buuaau16u9.:Cll'wwQ%8N■ 1' DRAWN BY: P.A.M. CHECKED BY: JJP SCALE: AS NOTED DATE: 11/08/02 PROF ES 1GINER SEAL 02619 C-3 i EROSION CONTROL GENERAL CONSTRUCTION SEQUENCE TEMPORARY EROSION CONTROL MEASURES THIS IS A GENERAL CONSTRUCTION SEQUENCE OUTLINE SOME ITEMS OF WHICH 1) DISTURBED AREAS SHALL BE KEPT TO THE MINIMUM AREA NECESSARY MAY NOT APPLY TO PARTICULAR SITES. TO CONSTRUCT THE ROADWAYS AND ASSOCIATED DRAINAGE FACILITIES. 1) CUT AND STUMP AREAS OF PROPOSED CONSTRUCTION. 2) HAY BALE BARRIERS AND SEDIMENT TRAPS SHALL BE INSTALLED AS REQUIRED. BARRIERS AND TRAPS ARE 2) INSTALL TEMPORARY SEDIMENT AND EROSION CONTROL TO BE MAINTAINED AND CLEANED UNTIL ALL SLOPES MEASURES AS REQUIRED. HAVE A HEALTHY STAND OF GRASS. 3) REMOVE AND STOCKPILE TOPSOIL. STOCKPILE SHALL BE 3) BALED HAY AND MULCH SHALL BE MOWING OF ACCEPTABLE POSTS 1. SET POSTS AND WIRE FE G 2. STAPLE THE WIRE SEEDED TO PREVENT EROSION. HERBACEOUS GROWTH, FREE FROM NOXIOUS WEEDS OR WOODY EXCAVATE A 6" X MESH FENCING STEMS, AND SHALL BE DRY. NO SALT HAY SHALL BE USED. ANGLE 1 V 6" TRENCH, SET TO END POST 4) CONSTRUCT CLOSED DRAINAGE SYSTEM. PRECEPT CULVERT UPSLOPE FOR POST DOWNSLOPE. INLETS AND CATCH BASINS WITH SEDIMENTATION BARRIERS. 4) FILL MATERIAL SHALL BE FREE FROM STUMPS, WOOD, STABILITY AND ROOTS, ETC. SELF CLEANING 5) CONSTRUCT ROADWAYS AND PERFORM SITE GRADING, PLACING HAY BALES AND SILTTATION FENCES AS REQUIRED TO 5) STOCKPILED MATERIALS SHALL BE PLACED ONLY IN AREAS CONTROL SOIL EROSION. SHOWN ON THE PLANS. STOCKPILES SHALL BE PROTECTED BY SILTATION FENCE AND SEEDED TO PREVENT EROSION. THESE 6) INSTALL UNDERGROUND UTILITIES. MEASURES SHALL REMAIN UNTIL ALL MATERIAL HAS BEEN ;� III„llltti+r111 i 11 r111=lllrtiir i - 11�=L=4�Il 111 fit= PLACED OR DISPOSED OFF SITE. is-111.- i11�111= 111= lti 7 BEGIN TEMPORARY AND PERMANENT SEEDING AND MULCHING. tiil_Ill�� _-111�1111;` titi1-1�l--II I I11�111�- ' ALL CUT AND FILL SLOPES SHALL BE SEEDED OR MULCHED s) ALL DISTURBED AREAS SHALL BE LOANED AND SEEDED. A Il`-IIII I 11� ��1f II`.111 1 111��I1 IMMEDIATELY AFTER THEIR CONSTRUCTION. NO AREA SHALL BE MINIMUM OF 4 INCHES OF LOAM SHALL BE INSTALLED WITH NOT i t tiwl lt� LEFT UNSTABILIZED FOR A TIME PERIOD OF MORE THAN 30 LESS THAN ONE POUND OF SEED PER 50 SQUARE YARDS OF 12" MIN. 0 PTH DAYS. AREA. 8) DAILY, OR AS REQUIRED, CONSTRUCT, INSPECT, AND IF 7) APPLICATION OF GRASS SEED, FERTILIZERS AND MULCH SHALL BE NECESSARY, RECONSTRUCT TEMPORARY BERMS, DRAINS, ACCOMPLISHED BY BROADCAST SEEDING OR HYDROSEEDING AT FILTER 3, ATTACH FILTER 4. BACKFILL THE DITCHES, SILT FENCES AND SEDIMENT TRAPS INCLUDING THE RATES OUTLINED BELOW: FABRIC FABRIC TO THE TRENCH AND MULCHING AND SEEDING. WIRE FENCING COMPACT THE LIMESTONE: 75-100 LBS./1,000 SQUARE FEET. AND EXTEND IT EXCAVATED SOIL. 9) BEGIN EXCAVATION FOR AND CONSTRUCTION OF TOWERS AND FERTILIZER: RATE RECOMMENDED BY MANUFACTURER. w TO THE TRENCH. PLATFORMS. MULCH: HAY MULCH APPROXIMATELY 3 TONS/ACRE UNLESS EROSION CONTROL MATTING IS USED. 10) FINISH PAVING ALL ROADWAYS, DRIVES, AND PARKING COMPACTED AREAS. NED MIX (SLOPES LESS THAN 4:1) LBS.f ACRE CREEPING RED RESCUE 20 BACKFILL 11) COMPLETE PERMANENT SEEDING AND LANDSCAPING. TALL RESCUE 20 10 r l T�`Ill.;;,lll.,i�t�111`Ill 11=lll�ll»j�ll�` tii��lllfl;l_i1�111j1 llil` 1--111=1±1=llri-" 12) NO FLOW SHALL BE DIVERTED TO ANY WETLANDS UNTIL A RED TOP U titil il_l11_1-Il L!1 111i11-' 4+�I-`11-11 ll l`I`111�11 HEALTHY STAND OF GRASS HAS BEEN ESTABLISHED IN 42 REGARDED AREAS. SLOPE MIX (SLOPES GREATER TAN 4:1) LBS.(ACRE 13) AFTER GRASS HAS BEEN FULLY GERMINATED IN ALL SEEDED CREEPING RED RESCUE 20 AREAS, REMOVE ALL TEMPORARY EROSION CONTROL MEASURES. TALL RESCUE 20BIRDS FOOT TREE FOIL 8 48 1 SEDIMENTATION CONTROL BARRIER-SILT FENCE coNSTiRucMoN sPEciFICA'noNs - SILT FENCE 8) AFTER ALL DISTURBED AREAS HAVE BEEN STABILIZED THE C--4 NOT TO SCALE TEMPORARY EROSION CONTROL MEASURES ARE TO BE REMOVED. FENCES. 1) THE GEOTEXTILE FABRIC SHALL MEET THE DESIGN CRITERIA FOR SILT 9) PAVED ROADWAYS MUST BE KEPT CLEAN AT ALL TIMES. 2 THE FABRIC SHALL BE EMBEDDED A MINIMUM OF 8 INCHES INTO THE 10) ALL CATCH BASIN INLETS WILL BE PROTECTED WITH GROUND AND THE SOIL COMPACTED OVER THE EMBEDDED FABRIC. LOW POINT SEDIMENTATION BARRIER. 3 WOVEN WIRE FENCE SHALL BE FASTENED SECURELY TO THE FENCE POSTS 11) ALL STORM DRAINAGE OUTLETS WILL BE STABILIZED AND CLEANED AS REQUIRED, BEFORE THE DISCHARGE POINTS WITH WIRE TIES OR STAPLES. BECOME OPERATIONAL. 4) FILTER CLOTH SHALL BE FASTENED SECURELY TO THE WOVEN WIRE 12) ALL DEWATERING OPERATIONS MUST DISCHARGE DIRECTLY INTO A BUTT HAY BALES FENCE WITH TIES SPACED EVERY 24 INCHES AT THE TOP, MID-SECTION SEDIMENT FILTER AREA. 2" SQUARE WOOD STAKE AND BOTTOM. TIGHT 2 PER BALE 13) NO DISCHARGE SHALL BE DIRECTED TOWARDS ANY PROPOSED 5) WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER, THEY DITCHES, SWALES, OR PONDS UNTIL THEY HAVE BEEN PROPERLY PLACE DIRT AGAINST SHALL BE OVERLAPPED BY 6 INCHES, FOLDED, AND STAPLED. STABILIZED, UPSLOPE FACE 6) FENCE POSTS SHALL BE A MINIMUM OF 36 INCHES LONG AND DRIVEN A MINIMUM OF 16 INCHES INTO THE GROUND. WOOD POSTS SHALL BE OF CONSTRU�.`TION SPECIFICATIONS - STRAW OR HAY BALES SOUND QUALITY HARDWOOD AND SHALL HAVE A MINIMUM CROSS SECTIONAL SET HAY BALES IN TRENC AREA OF 3.0 SQUARE INCHES. 4 INCHES BELOW GRADE 1) BALES SHALL BE PLACED IN A ROW WITH THE ENDS TIGHTLY 7) MAINTENANCE SHALL BE PERFORMED AS NEEDED TO PREVENT BUILD UP IN ADJOINING. THE SILT FENCE DUE TO DEPOSITION OF SEDIMENT. 2) EACH BALE SHALL BE EMBEDDED IN THE GROUND A MINIMUM OF 4 MAINTENANCE - SILT FENCE INCHES. EXISTING GRADE 3) BALES SHALL BE ANCHORED IN PLACE BY AT LEAST TWO STAKES DRIVEN 1) SILT FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL THROUGH THE BALE. THE STAKES SHALL BE DRIVEN AT LEAST 18 INCHES AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS THAT INTO THE GROUND. ARE REQUIRED SHALL BE MADE IMMEDIATELY. 4) BARRIERS SHALL BE INSPECTED AFTER EVERY RAINFALL AND PROMPTLY NOTE: A SECOND HAYBALE MAY BE 2 IF THE FABRIC ON A SILT FENCE SHOULD DECOMPOSE OR BECOME REPAIRED FOR REPLACED AS NECESSARY. REQUIRED WHERE SLOPE OR HEIGHT ) INEFFECTIVE DURING THE EXPECTED LIFE OF THE FENCE, THE FABRIC REQUIRES IT. SHALL BE REPLACED PROMPTLY. 5) BALES SHALL BE REMOVED WHEN NO LONGER NEEDED AND THE SEDIMENT COLLECTED SHALL BE DISPOSED OF PROPERLY. 3) SEDIMENT SHOULD BE INSPECTED AFTER EVERY STORM EVENT. 2 SEanON THRU HAYBALE EROSION CONTROL BARRIER TH EDEPOSITS SHEIGHHOULD OBE F THE OVED R WHEN THEY REACHED APPROXIMATELY MAINTENANCE _ STRAW OR HAY BALES C-4 NOT TO SCALE 4) SEDIMENT DEPOSITS THAT ARE REMOVED OR LEFT IN PLACE AFTER THE 1) STRAW OR HAY BALES SHALL BE INSPECTED IMMEDIATELY AFTER EACH FABRIC HAS BEEN REMOVED SHALL BE GRADED TO CONFORM WITH THE EXISTING RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL, TOPOGRAPHY AND VEGETATED. 2) CLOSE ATTENTION SHALL BE PAID TO THE REPAIR OF DAMAGED BALES, UNDERCUTTING BENEATH THE BALES, AND FLOW AROUND THE END OF THE BALES. NEC-MARY REPAIRS OR REPLACEMENT OF BALES SHALL BE ACCOMPLISHED PROMPTLY. 4) SEDIMENT DEPOSITS SHOULD BE CHECKED AFTER EACH RAINFALL. THE DEPOSITS SHOULD BE REMOVED WHEN THE LEVEL OF DEPOSITION REACHES APPROXIMATELY ONE-HALF OF THE HEIGHT OF THE TABLE. 5) SEDIMENT DEPOSITS THAT ARE REMOVED OR LEFT IN PLACE AFTER THE BARRIER HAS BEEN DISMANTLED SHALL BE GRADED TO CONFORM WITH THE EXISTING TOPOGRAPHY AND VEGETATED USING ■Natco .LLC•Engineering Consuttants ■ J 1C0�+�+ Z N 'f 1Tlf1f 1f1A, LLC Sprint Spectrum LP .3#, ; •}# } 63-2 North Branford Road AGAWAMSprinp f, t LP o Branford, Connecticut 06405 rr- 01/24/03 8 SPRINGFIELD ST4EFKXXM CONTROL DETALS Tel. (203)488-0580 . . / / PAN, JJP CFC ;V1 04 24 03 ISSUED FOR FINAL ZONING '�- '}} AGAV{IAM, MASSACHUSETTS Q1Q0'I (� 2 Fax(203)488-8587 l International Blvd•^-Sulte J00 ISSUED FOR PRELIMINARY ZONING REVIEW P.A.M. JJP CFC A� ND�s Tplu Consulting Engineers-Project Management v A4� N0. DATE REVISIONS BY CHK APPV �� JOB NO. DRAWING NUMBER REV. z 4 ..•.'"•.f..: •. :•.r�•= Civil WM NO. �CTMCi U Mahwah NJ 07495 Y * s gnsucO Buu88u&3.011`wwooieN DRAWN BY: PAM. CHECKED BY: JJP SCALE: AS NOTED DATE: 11/08/02 PR' SI ,., I"ER SEAL 02619 C-4 1