Loading...
8041_SITE PLAN- SNET - 1804 MAIN ST.�# `6G�I `JI �Q ��C�,f'1 SNGT `�ccti I �'1Ci� � �}��.+ 0 0 TOWN OF AGAWAM INTEROFFICE MEMORANDUM 0 Ma To: Planning Board CC: URS Greiner, File, VRK From: James T. Daley, P. E. Date: June 18, 1999 Subject: Site Plan - 1804 Main Street - SNET - SP 296 Per your request dated June 10, 1999 we have reviewed the plan entitled, "Springwich Cellular Limited Partnership, Wireless Communications Facility, Lennie's Fiberglass, 1804 Main Street, Agawam, MA, by URS Greiner Woodward Clyde A E-S, 500 Enterprise Drive, Rocky Hill, CT, dated 5/14/99, scale V = 40'" and we have the following comments: 1.) As a courtesy to the Conservation Commission, we note that the location of the proposed building is approximately 60' from the flagged wetlands and stream. The proposed building will be built on an existing gravel area, an additional +/-212 s.f. impervious area is being created. The plan includes the location of erosion/sedimentation control devices and details as well. 2.) As per the Storm Drain Ordinance, any site over an acre will require a Storm Drain Permit from the Department of Public Works. An application is enclosed (We are carbon copying to URS Greiner). If you have any comments or questions, please do not hesitate to contact our division. Sincerely, 3 jamt T. Daley, P.E. Town Engineer h:lengineerlsiteplanksp296-07.wpd sNEr Craig H. Parker Wepbi7wnllhersll Cellular Realty Advisors,Inc. Representing: SNET Wireless Services 500 Enterprise Drive,3"Floor Rocky Hill,CT 06067-3900 Office:(860)513-7234 Fax;(860)513.7190 Mobile:(860)989-2707 Pager: 1-203-680-1043 AGAWAM OFFICE OF PLANNING & COMMUNITY DEVELOPMENT SITE PLAN REVIEW REVIEWER: Deborah S. Dachos DATE: June 14, 1999 DATE RECEIVED: June 10, 1999 DISTRIBUTION DATE: June 10, 1999 PLANNING BOARD MEETING DATE: June 17, 1999 APPLICANT INFORMATION 1. Name of Business: Springwich Cellar Limited Partnership Address: 500 Enterprise Drive, 3rd Floor, Rocky Hill, CT 06067 2. Owner: Same Address: Telephone: (860) 513-7234, Fax (860) 513-7190 3. Engineer: USR Greiner Woodward Clyde Address: 500 Enterprise Drive, Rocky Hill, CT 06067 Telephone: (860) 529-8882 PLAN REVIEW Scale: 1"=40' Date: May 14, 1999 Title Block (Street Address, Applicant's Name, Address, Scale, Name of Preparer of Plan): O.K. Description of Project: Installation of an antenna on an existing cell tower and new equipment building. Site Plan Review Page 2 Description of Site: The location of the proposed antenna and equipment building is the Omnipoint site at 1804 Main Street. The Planning Board approved the Site Plan for this tower on February 20, 1998. The Site Plan approval letter is enclosed for your information. One of the conditions of the approval was the replacement of some of the trees which had to be removed. Other trees were proposed to be planted along the northern property line. To date these plantings have not been done. Provision for Traffic Flow: Unchanged. Parking: Not shown. Drainage: Unchanged. Public Utilities: Not shown. Landscaping/Screening and Buffers: As indicated above, the landscaping proposed by Omnipoint has not been installed. Sign Location: Not shown. Exterior Lighting: Not shown. Rendering or Elevations: No elevations have been provided for the new equipment building. An elevation of the pole with the new antenna has also not been provided. Dumpster Location: N.A. Other Comments or Concerns: During a earlier review of the installation of a new antenna at the Bell Atlantic site at the Southend Bridge, Bell Atlantic was ordered to address deviations from their approved plan. This is a similiar situation. 0 9� TOWN OF AGAWAM �. :l: ;�. i• :36NIAIN STREET AGAWAN1. N-1ASSACHC'SETTS 01001 y Tel. 413- 86-0400 RTEA February 20, 1998 James Ross Omnipoint Communications Enterprises, Inc. 1655 Main Street Springfield, MA 01103 Re: Lennie's Site - 1804 Main Street Dear Mr. Ross: cdli At its duly called meeting held on January 19, 1998, the Agawam Planning Board voted to approve the Site Plan entitled "Site Plan Modification, Omnipoint Communications, Inc" prepared by USR Greiner and dated February 19, 1998 with the following conditions: 1. The Planning Board approval is conditional upon the meeting of all conditions of the Board of Appeals approval date December 2, 1997. Since the proposed location of the tower has been changed, a revised approval of the Board of Appeals may be necessary. 2. All Engineering comments must be addressed. Since the revised plan was received at the Planning Board's January 19, 1998 meeting, Engineering review of the plans was not possible prior to Planning Board action. 3. A detail revised landscaping plan shall be submitted. This plan will be prepared after input is received from the Director of Planning and the Planning Board. The plan shall address the area to the east of the tower location. Three (3) sets of the revised Site Plan incorporating the above shall be submitted to the Planning Board for its approval. If you have any questions, please do not hesitate to contact the Planning Office at 786-0400, extension 283. Sincerely, r Charles R. Calabrese, Chairman J Sz Agawam Planning Board cc: Attorney Bodurtha Town Clerk Attorney Locke Conservation Commission � Board of Appeals Engineering File TOWN OF AGAWAM 36 MAID STREET AGAW AM, M ASSACHUSETTS 01001 - Tel. 413 86-0400 � MA LO I. July 23, 1999 m y f r ILO .. C . Craig H. Parker SNET 500 Enterprise Drive 3'4 Floor Rocky Hill, CT 06067-3900 At its duly called meeting held on July 22, 1999, the Agawam Planning Board voted to approve the Site Plan entitled: "Springwich Cellular Limited Partnership, Wireless Communications Facility, Lennie's Fiberglass, 1804 Main Street, Agawam, Massachusetts" prepared by URS Greiner Woodward Clyde and dated May 14, 1999, revised June 9, 1999. Sincerely, 1 CX� 66 Charles R. Calabrese, Chairman Agawam Planning Board cc: Clerk Building Engineering Springwich Cellular Limited Partnership 0 0 TOWN OF AGAWAM tillo INTEROFFICE MEMORANDUM oR, rED MP To: Planning Board CC: URS Greiner, SNET, File, VRK From: Engineering Division Date: July 7, 1999 Subject: Site Plan - 1804 Main Street - SNET - SP 296 Per your request dated June 10, 1999 we have reviewed the plan entitled, "Springwich Cellular Limited Partnership, Wireless Communications Facility, Lennie's Fiberglass, 1804 Main Street, Agawam, MA, by URS Greiner Woodward Clyde A-E-S, 500 Enterprise Drive, Rocky Hill, CT, dated 5/14199, scale 1" = 40'" and we would like to add the following comment to our memorandum sent to the Planning Board dated June 18, 1999 (attached): 1.) We have received Storm Drain Calculations and a Strom Drain Permit application for this site and we approve the submitted calculations. We will grant a Strom Drain Permit. The additional impervious area does not create any additional run-off for the 2 yr., 10 yr., or 100 yr. Storms. If you have any comments or questions, please do not hesitate to contact our division. Yours truly, Sincerely, John R Stone Van co annakis DPW Superintendent Civil Engineer I h:le*neerlsitep1anlsp296_08.wpd i . '` • • TOWN OF AGAWAM o INTEROFFICE y� 1� MEMORANDUM MPy� To: Planning Board CC: URS Greiner, File, VRK From: James T. Daley, R E. Date: June 18, 1999 Subject: Site Plan - 1804 Main Street - SNET - SP 296 Per your request dated June 10, 1999 we have reviewed the plan entitled, "Sprnigwich Cellular Limited Partnership, Wireless Communications Facility, Lennie's Fiberglass, 1804 Main Street, Agawam, MA, by URS Greiner Woodward Clyde A E-S, 500 Enterprise Drive, Rocky Hill, CT, dated 5/14/99, scale 1" = 40'" and we have the following comments: 1.) As a courtesy to the Conservation Commission, we note that the location of the proposed building is approximately 60' from the flagged wetlands and stream. The proposed building will be built on an existing gravel area, an additional +/-212 st impervious area is being created. The plan includes the location of erosion/sedimentation control devices and details as well. 2.) As per the Storm Drain Ordinance, any site over an acre will require a Storm Drain Permit from the Department of Public Works. An application is enclosed (We are carbon copying to URS Greiner). If you have any comments or questions, please do not hesitate to contact our division. Sincerely, , ames T. Daley, P.E. Town Engineer h:lengineerlsiupl=Xsp296_0'7.wpd sH June 2, 1999 Mr, Van Kacoyannakis Department of Public Works 36 Main Street Agawam, MA 0 100 1 RE: Springwich Cellular Limited Partnership Storm Drainage Permit Application Dear Mr. Kacoyannakis, Per the direction of Mr. James Daley, I am directing to your attention the Storm Drainage Permit Application for the proposed wireless communications facility installation on the existing tower at 1804 Main Street(Lennie's Fiberglass). Upon your review of the enclosed application and supporting documentation, please follow up prior to the July 15"public hearing for this proposed installation to address any additional questions or concerns of the DPW. I will interpret a lack of follow up by your office to mean that there are no additional questions or concerns and that the applicant has met the conditions of the DPW. I may be contacted at 860.513.7234. Thank you for your time and attention to this matter. Very truly yours, Craig H. Parker CHP/ Enclosures C: Ms. Deborah S. Dachos, Director of Planning&Community Development i• ` JUL 0 S 3!u3 qQ� TOWN OF AGAWAM a, 36 MAIN STREET AGAWAM. M_ASSACHUSETTS 01001 y Tel. 4I3-7 86-0-400 June 21, 1999 Paul A. DeCoste UniSite S Tananger Road Plymouth, MA 02360 _ Dear Mr. DeCoste: Attached please find a memo from Stephen P. Ruzzo of UniSite to Dominic Urbinati, Commissie ie of Buildings, regarding the planting of trees at the 1804 Main Street site. The planting of trees*vas a requirement of the Planning Board in its February 20, 1998 approval of the Site Plan fytthe-A--`; construction of a telecommunications tower. On June 17, 1999, the Planning Board had beare it t F a petition by SNET to place another antenna on the tower located at 1804 Main Street. PHr to r action on this petition, the site was visited to ensure conformance with the approved plan_ It was discovered that the trees that were to be planted still have not been planted even though the Ruzzo memo of December 14, 1998 indicated that they would be planted by May 1999. The Board will take no action on the SNET petition until it is satisfied that the conditions of the approval for the tower have been met. The Board suggest that since this is not the time of year for planting of trees, particularly large trees, that a bond be posted until the trees can be planted in the Fall. The Town would be happy to provide you with an amount sufficient to cover the cost of the trees. Please be advised that if no action is taken regarding this matter, the Board will request that the Building Inspector condemn the site. If you have'any questions, please contact the Planning Office at 786-0400, extension 283. Sincerely, Charles R. Calabrese, Chairman Agawam Planning Board CC' Clerk Building SNET n^EC-14-1998 15:23 FROM 14137869927 P.01 7{ Memo Toe Donn nic Urt inad _ yn sir,^ � •�i/V RM Stephen P.Remo Onto 12(14l98 Rw Landscaping far Communica,atition Tcwer at 1802 Main SL The landscaping tbrthe communica tow at 18M Main St, Lermies Fbi erglasswig commence in the spring of 1999 and scheduled for =T pMw by the and of May 1999, pending w w9w. The present climate is not conducive to the propagation of any planbrigs, and the avabbiaty of ., marry of the species in the lar iscaping plan are not readily available until the spring. Although this schedule delays the completion of the approved plans, it is the best way to ensure that the fhal porWn of the sibs a completed=Tac iy. Unite is,requesting brat the necessary approvals be granted such that the site be allowed to go online with this guarantee, that the remaining wok be completed with due d kjer ce at the desk passible time. Please contact me at 508-M7-1301 to disaw anything further. ! 0 1 A�� TOWN OF AGA,WAM 11' _ �l� 36 MAIN STREET AGAWAM, MASSACHUSETTS 01001 y - Tel. 413-"g6-0400 0 MEMO TO: Building Inspector, Engineering Dept., Fireiept-, Police Dept. FROM: Planning Board DATE: June 10, 1999 SUBJECT: Site Plan - 1804 Main Street - SNET Please review and co t on the attached SNET Site Plan prior to the Board's June 1 Th Meeting. �' WAM FIRE DEPARTMENT- Thank you. APPROVAL DATE,. DSD:prk s- AGAWAM PLANNWG BOARD Form D Application for Site Plan Approval Please complete the following farm and return it and 10 copies of the Site Plan to: Agawam Planning Board Office of Planning and Community Development 36 Main Street Agawam, MA 01001 L. Name of Business Springwich Cellular Limited Partnershi2 Address 2. Name of Applicant/Owner Springwich Cellular Limited Partnership Address_500 Enterprise Drive, 3rd_FL Rocky- Hi1I, CT_ 06067 _ Telephone 860.513.72349 Fax 860.513.7190 3_ Name of Engineer/Architect URS Greiner Woodward Clyde _ Address Telephone 860.529.8882 4. Please give a brief description of the proposed project: Installation of wireless communications facility at 1.804 Main Street, Agawam, MA, Revised 11/06/99 MEMO To: Planning Board From: Sergeant Donald Gallerani S Subject: Site Plan-1804 Main Street-SNET Date: June 16, 1999 The installation of a wireless communications facility at 1804 Main Street has no bearing on traffic or pedestrian safety. A@ : TOWN OF AGAWAM 36 MAIN STREET AGAWANI, NIASSACHUSETTS 01001 y - Tel. 413-7 46-0400 11 � MEMO TO: Building InspecZrEngineering Dept., Fire Dept., Police Dept. FROM: Planning Board DATE: June 10, 1999 SUBJECT: Site Plan - 1804 Main Street - SNET Please review and comment on the attached SNET Site Plan prior to the Board's June 17' meeting. Thank you. DSD:prk ll 5 G �- l� St 'JUN 1 f 1999 AGAWAM BUILDING UP I S) SNET Wireless Services S' E***T 500 Enterprise Drive Rocky Hill,CT 06067 June 16, 1999 Deborah S. Dachos Town of Agawam Director of Planning & Community Development 36 Main Street Agawam, MA 01001 RE: Installation of wireless communications facility at 1804 Main Street, Agawam, MA Dear Ms. Dachos, Attached are revised drawings of the proposed SNET installation at 1804 Main Street based upon your comments dated June 14, 1999. An elevation view has been inserted as well as yard setbacks on the plan view. I will discuss your comments, as well as Springwich's proposal, at the hearing scheduled June 17, 1999. I may be contacted at 860.513.7234 if you have additional comments or questions regarding this matter prior to the hearing. Very truly yours, C.I. a:. 41:?m.�.lc,,,.,�. 3 Craig H. Parker CHPI Enclosures 6 1� 9 I�. AB,� TOWN OF AGAWAM a, 36 MAIN STREET AGAWAN1, M ASSACHUSETTS 01001 Tel. 4 13-;96-0400 � MA MEMO TO: Building Inspector, Engineering Dept., Fire Dept., Police Dept. FROM: Planning Board DATE: June 10, 1999 SUBJECT: Site Plan - 1804 Main Street - SNET Please review and comment on the attached SNET Site Plan prior to the Board's June 17' meeting. Thank you. DSD:prk AGAWA.M PLANNING BOARD � Form D Application for Site Plan ApprovalCD Please complete the following form and return it and 10 copies of the Site Plan to: Agawam Planning Board Of me of Planning and Community Development 36 Main Street Agawam, MA 01001 L. NameofBusiness Springwich Cellular Limited Partnership Address 2. Name of ApplicantlOwner Springwich Cellular Limited Partnership Address 500 Enter rise Drive 3rd FL Rocky Hill CT 060 7 Telephone 860.513.7234, Fax 860.513.7190 _ R 3. Name of Engineer/Architect URS Greiner Woodward Clyde Address_500 ntPULi se DDr1Ue, Rnc%y Hi j i , C1 06.0I,,.. Telephone 860.529.8882 4. Please give a brief description of the proposed project. Installation of wireless communications facility at1804 Main Street, Agawam, MA. p F°fig e' j Revised 11/06/99 % ` g L O N fir:� Orn TO W OC �- . t LOC V L L �Z4 U cc V) 04 O u. x a 4 AGAWAM PLAN ]MG BOARD Form D Appllcatioa for Site'Plan Approval Please complete the following form and return it and 10 copies of the Site Plan to: Agawain Planning Board Office of Planning and Conununity Development 36 Main Street Agawam, MA 01001 I. NameofBusiness Springwich Cellular Limited Partnership ._ Address 500 fnteL ca Drive, ,3Ld Ft Rnr 56 Hi 7 I . ('.I_ QLfiQA7 _ 2. NatneofApplicant/Owner 5pringwich Cellular Limited Partnership Address 500 Enterprise Drive— 3rd FL Rocky. Kills_ CT_ 060�7 Telephone 860.513.72341 Fax 860.513.7190 3- Name of Engineer/Architec# URS Greiner Woodward _Cl_yde Address 500 EjtpLnri Sp-- Drive, Ricky_ Hi 11 �T— 6.0 067 — Telephone 860.529.8882 4. Please give a brief description of the proposed project: Installation of wireless communications facilit 4 Main Street, Agawam, MA. Revised 11/06/98 ,� ` AGAWAM PLA.NNYNG BOARD Form D Application for Site Plan Approval Please complete the following form and return it and 10 copies of the Site Plan to: Agawam Planning Board Office of Planning and Community Development 36 Main Street Agawam, MA 01001 1. NamoofBusiness Springwich Cellular Limited Partnership Address 2. Name of Applicant/Owner LPringwi—ch Cellular Limited Partnership Address 500 Enterprise pri ve 3rd_FL Rocky Hi 1_]—_CT_ 06067 Telephone 860.513.72349 Fax 860.513.7190 3. Name of Engineer/Architect URS Greiner Woodward Clyde Address Telephone 860.529.8882 4. Please give a brief description of the proposed project: Installation of wireless communications facility at 1804 Main Street, Agawam, MA. Revised 11/06/99 J AGAWAM PLANNING BOARD Form D Application for Site Plaa Approval Please complete the following form and return it and 10 copies of the Site Plan to: Agawam Planning Board Office of Planning and Community Development 36 Main Stret Agawam, MA 01001 I. Name of Business Springwich Cellular Limited Partnershi Address 2. Name of Applicant/Owner Springwich Cellular Limited Partnership Address 500 Enterprise Drive 3rd FL Rocky Hill CT 06067 Telephone 860_513.7234, Fax 860.513.7190 3. Name of Enginaer/Architect URS Greiner_Woodward Clyde Address_SOO EnteEpri5g DCiv , RockyJ3i 1J, CZ 06067 Telephone $60.529.8882 4. Please give a brief description of the proposed project: Installation of wireless communications facility at 1804 Main Street, Agawam, MA. fir o � Revised 11/06/98 bl� AGAWAM PLANNYNG BOARD Form A Application for Site Plan Approval Please complete the following form and return it and 10 copies of the Site Plan to: Agawam Planning Board Office of Planning and Community Development 36 Main Street Agawam, MA 01001 1. Name of Business Sprin with Cellular Limited Partnership Address 2. Name of Applicant/OwnerSpringwich Cellular Limited Partnership Address 500 enterprise Drive. 3rd FL _ Rocky, Hill . CT 06067 Telephone 860.513.7234, Fax 860.513.7190 3. Name of Engineer/Architect URS Greiner Woodward _Clyde Address_500„Fntprnri5e Qri ve,_RockyJJi 11, CL 06067 Telephone 860-529.8882 4. Please give a brief description of the proposed project: Installation of wireless communications facility at 1804 K6Ja - Street, Agawam, MA. Devised 11/06/98 .� 1 1 1 1 LOG 1 Box # � 1 DOCUMENT# f 1 C.� PAGE # r� PROJECT SUMMARY SITE NAME: TOWN OF AGAWAM ll ; W H CELLULAR SPRIN I SffE i4DDRESS: 1804 MAIN STREET AGAWAM, MASSACHUSETTS CONTACT PERSON: SNET MOBILITY-ROCKY HILL TOM FENTON A&E FIRM (860) 513-7601 AV bvifiw Rbo&wrd Clj* SITE I-IARPEL NO.: LOT 3 F, A-E-S DEED BOOK / PAGE 3452/51 500 ENTERPRISE DRIVE ROCKY HILL, CONNECTICUT CURRE-NT ZONING: INDUSTRIAL A 1-(860Y529-8882 A&E SEAL APPU��ANT'. SPRINGWICH CELLULAR FIBERGLASS LIMITED PARTNERSHIP ENNIE S 500 ENTERPRISE DRIVE Fi ROCKY HILL, CT. 06067 LIMITED PAR FN .. RSHIP WIRELESS COMMUNICATIONS FACILITY ARCHITECT-. URS GREINER WOODWARD CLYDE A.E.S. 500 ENTERPRISE DRIVE ROCKY HILL, CT 06067 1804 MA. IN STREET M/E/P ENGINEER: URS GREINER WOODWARD CLYDE A.E.S. 500 ENTERPRISE DRIVE ROCKY HILL, CT 06067 AGAWAM MA SURVEYOR: URS GREINER WOODWARD CLYDE A.E.S. PERMrMNG 500 ENTERPRISE DRIVE ROCKY HILL, CT 06067 ONLY SSACHUSE FTS f I [NOT FOR CONSTRU00N GENERAL NOTES VICINITY MAP NO SCALE SHEFT INDEX F I. CONTRACTOR SH&L REFER To 514ET SPECIFICATIONS ENTITLED 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ON-SITE SAFETY SHT� PROJECT NO: F301804.01 /FO4 "GENERAL CONDITIONS FOR CONSTRUCTION" DATED, FEB. 1998. FROM THE TIME THE JOB IS AWARDED UNTIL ALL WORK IS NO. COMPLEW_ AND ACCEP�'ED BY THE OWNER. N DRAWN BY: WJK 2. ALL WORK SHALL COMPLY WITH THE LATEST COMMONWEALTH 10. CONTRACTOR TO REVIE4 ALL SHOP DRAWINGS AND SUBMIT OF MASSACHUSSETS STATE BUILDING CODE AND SUPPLEMENTS. COPY TO ARCHITECT FOR 'APPAOVAL. DRAWINGS MUST BEAR THE CHEQKV"-fNMA'.l-_BEFORE SUBMITTAL TO THE 3. CONTRACTOR SHALL REVIEW ALL DRAWINGS AND ARCHITECT FOR REVIb'd', T-i (,t-I&RAL NOTES AND LEGENCS CHECKED BY: SPECIFICATIONS IN THE CONTRACT DOCUMENT SET. J CONTRACTOR SHALL COORDINATE ALL WORK SHOWN 11. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, IN THE SET OF DRAWINGS. THE CONTRACTOR SHALL ELEVATIONS, ANGLES, AND EXISTING CONDITIONS AT THE ISSUED FOR PROVIDE A COMPLETE SET OF DRAWINGS TO ALL SITE, PRIOR TO FABRICATION AND/OR INSTALLATION C-1 SI I L PLAN SUB- CONTRACTORS AND ALL RELATED PARTIES. THE OF ANY WORK IN THE CONTRACT AREA. 05-14-991REMEW SUB-CONTRACTORS SHALL EXAMINE ALL THE DRAWINGS C-2 COMPOUND PLAN, NOTES AND LEGEND )6-09-99 ISSUED FOR PERM17NG AND SPECIFICATIONS FOR THE INFORMATION THAT 12. THE CONTRACTOR IS SOLELY RESPONSIBLE TO DETERMINE LEfoEND AFFECTS THEIR WORK. CONSTRUCTION PROCEDURE AND SEQUENCE, AND TO ENSURE 4. CONTRACTOR SHALL PROVIDE A COMPLETE BUILD-OUT THE SAFETY OF THE FXISTING BUILDING AND ITS COMPONENT C-3 FOUNDATION PLAN, NOTES AND DETAILS SyHBOL D E S C R I P T 1 0 N PARTS DURING CONSTRUCTION. THIS INCLUDES THE ADDITION WITH ALL FINISHES, STRUCTURAL, AND ELECTRICAL OF SHORING, BRACING, UNDERPINNING, ETC. THAT COMPONENTS AND PROVIDE ALL ITEMS AS SHOWN OR MAY BE NECESSARY. INDICATED ON DRAWINGS OR WRITTEN IN SPECIFICATIONS. 13. COORDINATE ALL CIVIL AND ELECTRICAL DRAWINGS FOR THE RIVERVIEW S.T. 5. CONTRACTOR SHALL FURNISH ALL MATERIAL, LABOR AND LOCATION OF ALL OPENINGS, RECESSES, BUILT-IN WORK, ETC. SECTION OR DETAIL NUMBER EQUIPMENT TO COMPLETE THE WORK AND FURNISH A SHEET WHERE DETAIL/SECTION OCCURS COMPLETED JOB ALL IN ACCORDANCE WITH LOCAL AND STATE GOVERNING AUTHORITIES AND OTHER AUTHORITIES 14. CONTRACTOR SHALL COMPLY WITH OWNERS ENVIRONMENTAL HAVING LAWFUL JURISDICTION OVER THE WORK. ENGINEER ON ALL METHODS AND PROVISIONS FOR ALL EXCAVATION ELEVATION NUMBER THE INFORMATION CONTAINED ACTIVITIES INCLUDING SOIL DISPOSAL. ALL BACKFILL MATERIALS 6. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND TO BE PROVIDED BY THE CONTRACTOR. SHEET WHERE ELEVATION OCCURS IN THIS SET OF DOCUMENTS ALL INSPECTIONS REQUIRED AND SHALL ALSO PAY FEES IS PROPRIETARY BY NATURE. REQUIRED FOR THE GENERAL CONSTRUCTION, PLUMBING, 15. FOR EXISTING PROPERTY LINE AND TOPOGRAPHIC DATA, SEE MAP WOODC ­ ANY USE OR DISCLOSURE ELECTRICAL AND HVAC. SUB-CONTRACTORS SHALL PAY ENTITLED "PARTIAL BOUNDARY & TOPOGRAPHIC SURVEY, LAND OF L-1 Fr_ FOR THEIR PERMITS. LENNIE'S FIBERGLASS 1804 MAIN STREET AGAWAM, MA OTHER THAN THAT WHICH 7. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF DRAWINGS PREPARED FOR SNET MOBILITY, INC. DATED: 02-16-99 RELATES TO SNET IS AND SPECIFICATIONS ON SITE AT ALL TIMES AND INSURE THE ALTANTIS GROUP, INC. 797 WASHINGTON STREET NEWTONVILLE, MA STRICTLY PROHIBITED. DISTRIBUTION OF NEW DRAWINGS TO SUB-CONTRACTORS AND bi OTHER RELEVANT PARTIES AS SOON AS THEY ARE MADE 16. CONTRACTOR TO CONTACT *DIG SAFE* AT 1-888-344-7233 AVAJLABLE. ALL OLD DRAWINGS SHALL BE MARKED VOID TO VERIFY AND IDENTIFY THE EXACT LOCATIONS OF ALL Lli AND REMOVED FROM THE CONTRACT AREA. CONTRACTOR UNDERGROUND UTILITI�S AND OBSTRUCTIONS PRIOR SHALL FURNISH 'AS-BUILT' SET OF DRAWINGS TO OWNER TO COMMENCING WORK IN THE CONTRACT AREA. LENNIE'S UPON COMPLETION OF PROJECT. 17. ALL ANTENNAS. ANTENNA DOWN TILT BRAKETS, COAXIAL CABLES Lli FIBERGLASS 8. ALL EQUIPMENT AND PRODUCTS PURCHASED ARE TO BE AND COAXIAL CONNECTORS ARE FURNISHED AND INSTALLED BY Lij REVIEWED BY CONTRACTOR AND ALL APPLICABLE OTHERS AND ARE SHOWN FOR COORDINATION PURPOSES ONLY. Of SUB-CONTRACTORS FOR ANY CONDITION PER MFR'S SITE 1804 MAIN ST. RECOMMENDATIONS. CONTRACTOR TO SUPPLY THESE ITEMS AT NO COST TO OWNER OR ARCHITECT. AGAWAM, MA 01001 ABBREVIATIONS SCALE: AS NOTED < KANAWHA AVE EXIS1, EXISTING FF FINISHED FLOOR WF WETLANDS FLAG DATE: 05-14-99 T.O.C. TOP OF CONCRETE T.O.F. TOP OF FOUNDATION (TYP,) TYPICAL DRAWING 1 OF 7 GENERAL NOTES ANDLEGENDS IF Agawam Engineeting Div. JUN I 1 1 9 JUL 2 6 19,49 A6kVAVl U-1 11 GDEPI. T- 1 A&E FIRM Lm ftifiw d"rd Im I CIN* A-E%S 500 ENTERPRISE DRIVE ROCKY HILL, CONNECTICUT 1-(860Y529-8882 A&E SEAL J CENTER OF EXI'All,k, IVIONO�OLE LATITUDE� N42'01 `.,�, �- LONGITUDE: PERM"NG GROUND [I-= 7-1 TOP EL.: 265. l ' i �M ONLY WIF F—W—F W F PES-202 [��-201 CS-20( NOT FOR CONSTRUCT] N I- H[ f--qF—1 WF IPES-20 W-2()� Es- 'Zo- IRFS -'o 64' WIF WF RES-20 RES-20 I[W PROJECT NO: F301804.0 S88"-- ] , 0"E p 3 \ L:� — 11 t A',0vl F.H I 7'56'40' h N8 7-7 DRAWN BY: WJK FF 07 �15� F7 A\A RES-21 N\ 2 166,32� WIF CHECKED BY: WF IRON —--—-- 1' 111 It E .=7 ISSUED FOR So H 01 I �WN FF 05-14-99 RE\IEW RES-211 WF W F )6-09-99 ISSUED FOR PERMIUNG w RES-20 W F W F v RES-16 70 ./- 1> '11, �L� I /"' " X- ES 12 V\ A AM I!,A]AVIIA ES vv r N(' jil OCK C" 0;6 S-18 F APPROXIMATE LOCATION OF STR A THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS VO IS PROPRIETARY BY NATURE. v Nk 01 ANY USE OR DISCLOSURE it. OTHER THAN THAT WHICH I wl RELATES TO SNET IS VD- cl Ws 1 101 STRICTLY PROHIBITED. LENNIE'S FIBERGLASS 1804 MAIN ST. AGAWAM, MA 01001 SCALE: AS NOTED SrM P4 APPROVAL AGAWAM PLLANNING BOARD t".)lp fp 619 X-lh�l DATE: 05-14-99 D-RAWING 2 OF 7 SITE PLAN SITE PLAN j Ij��j 15 9 C. 1 SCALE: 1"= 40'-0" I ING Hl' I SITEWORK - GENERAL NOTES 1. SEE GENERAL NOTE (11) ON SHEET T-1 FOR REFERENCE MAP INFORMATION. 2. ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM OF 1929. 3. THE FOLLOWING STANDARD SPECIFICATIONS ARE INCORPORATED INTO THE WORK SHOWN HEREON UNLESS SUPERSEDED BY LOCAL (TOWN) REGULATIONS: - COMMONWEALTH OF MASSACHUSETTS DEPARTMENT OF PUBLIC WORKS STANDARD SPECIFICATIONS FOR HIGHWAYS AND BRIDGES A&E FIRM 1988 OR LATEST REVISIONS THERETO 4. THE CONTRACTOR SHALL ESTABLISH AND MAINTAIN SOIL EROSION AND mus ovififf fto&wfd cly* SEDIMENTA71ON CONTROLS AT ALL TIMES DURING CONSTRUCTION. ALL A-E-S SOIL EROSION AND SEDIMENTATION CONTROL MEASURES ARE SUBJECT TO 500 ENTERPRISE DRIVE INSPECTION AND MONITORING BY THE TOWN. 5. ALL AREAS DISTURBED BY THE CONSTRUCTION OF IMPROVEMENTS ROCKY HILL, CONNECTICUT SHOWN HEREON SHALL BE REESTABLISHED TO EXISTING CONDITIONS. 1-(860Y529-8882 6. COORDINATION, LAYOUT AND FURNISHING OF CONDUIL CABLE AND ALL APPURTENANCES REQUIRED FOR PROPER INSTALLATION OF ELECTRICAL AND TELECOMMUNICATION SERVICE SHALL BE SOLELY RESPONSIBILITY OF A&E SEAL THE CONTRACTOR. 7. THE EXACT BUILDING FOUNDATION SIZE AND BUILDING FLOOR PENETRATIONS FOR UTILITIES SHALL BE CONFIRMED WITH THE BUILDING SPECIFICATIONS AND PLANS PRIOR TO LAYOUT. 8. ALL UTILITY WORK SHALL BE IN ACCORDANCE WITH LOCAL UTILITY COMPANY PROPERTY LINE REQUIREMENTS AND SPECIFICATIONS. 9. ALL DISTURBED AREAS SHALL BE RESTORED TO MATCH PRECONSTRUCTION CONDITIONS 10. THE CONTRACTOR SHALL CONTACT ODIG SAFEw AT LEAST 48 HOURS qr PRIOR TO ANY EXCAVATIONS. AL 11. IF ANY FIELD CONDITIONS PRECLUDE COMPLIANCE WITH THE DRAWINGS AND/OR CONDITIONS SPECIFIED. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THIS CELLULAR CARRIER AND SHALL NOT PROCEED WITH ANY AFFECTED WORK. 12. THE CONTRACTOR SHALL INSTALL ALL EROSION AND SEDIMENTATION CONTROL MEASURES PRIOR TO ANY GRADING ACTIVITIES. 13. THE CONTRACTOR SHALL STABILIZE ALL UTILITY LINE PERMrMNG TRENCHES WITHIN FIVE WORKING DAYS AFTER EXCAVATION ONLY UNLESS OTHERWISE APPROVED BY THIS CELLULAR CARRIER. EXISII14(, CIENIFIR NOT FOR CONSTRUCTION Exl�i-[W,IG - EXISTING TEIL.00 CATE ENCLOSURE Fil PROJECT NO: F301804.01XF04 DRAWN BY: WJK l-,W I LWIPMENT Bk)ll DING CONCRETE PAD APPROXIMATE LOCATION OF EXISTING MONOPOLE ( 1�'' 0`06'-0") AT BUILDING ENTRANCE ICHECKED BY: FOUNDATION REFER TO 1/C-3 REFER TO 1/C-3 Lk 101- - 14.6 TOC 74.1 74 x ISSUED FOR 0 -14-99 REMEW 5 X 74 )6-09-99 ISSUED FOR PERMInNG EXISTING CARRIERS EQUIPMENT PAD X 74 EXISTING MONOPOLE SNET ANTENNA THE INFORMATION CONTAINED PLATFORM IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ' 00 4 ANY USE OR DISCLOSURE OTHER THAN THAT WHICH EXISTING CHAIN LINK FENCE RELATES TO SNET IS BUILDING EDGE STRICTLY PROHIBITED. PARALLEL W/FENCE EDGE SEDIMENTATION CONTROL REFER TO 9/C-3 LENNIE'S 65019 SNET ICE BRIDGE FIBERGLASS REFER TO 7/C-3 1804 MAIN ST. AGAWAM, MA 01001 SCALE: AS NOTED DAT 05-14-99 DRAWING 3 OF 7 IEGEND DESCRIPTIONS EXISTING PROPOSED COMPOUND PLAN, PROPERTY LINE —--—-- NOTES AND LEGEND CHAIN LINK FENCE rl COMPOUND PLAN CONTOUR LINES �jo SCALE: 1"= 5'-0" SPOT ELEVATION i u N 1999 X180 SEDIMENTATION CONTROL FENCE 7� AGAVv'AM6-!'iLfjiNG0 C-2 SITEWORK - STRUCTURAL NOTES WIRE 1. SOIL BEARING CAPACITY OF 2,000 PSF USED FOR FOUNDATION DESIGN. POSTS 1. SET POSTS AND FENCING 2. STAPLE THE GENERAL CONTRACTOR RESPONSIBLE FOR VERIFYING BEARING CAPACITIES. EXCAVATE A 6* X 6" WIRE MESH ANGLE 10, TRENCH, SET POST FENCING TO 2. ALL SURFACES MUST BE FREE OF STANDING WATER PRIOR TO POURING UPSLOPEFOR DOWNSLOPE. END POST 'E FIR 0 CONCRETE STABILITY AND 'L 3. COMPACTED GRAVEL FILL PER MASSACHUSETTS DOT STANDARD SPEC. SELF CLEANING SECTION M 1.03.0 TYPE B 1. ALL DETAJILING, FABRICATION AND PLACING OF REINFORCING BARS SHALL 7� I 13E IN ACCORDANCE WITH THE LATEST A.C.I. MANUAL OF STANDARD �1� 01,11 A&E FIRM PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (A.C.I. 315). 2. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 12" MIN Off Wohw WmAmid Cly* BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (A.C.I. 318-83). DEPTH A-E%S 3. REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615 500 ENTERPRISE DRIVE (GRADE 60). ROCKY HILL, CONNECTICUT 4. THE CONTRACTOR SHALL FURNISH CONCRETE WITH A MINIMUM COMPRESSIVE FILTER 1-(860Y529-8882 STRENGTH OF 3,500 PSI AT 28 DAY. FABRIC 3. ATTACH FILTER FABRIC 4. BACKFILL THE TO THE WIRE FENCING TRENCH AND AND EXTEND IT TO THE COMPACT THE TRENCH. EXCAVATED SOIL. A&E SEAL COMPACTED BACKFILL oV- MICROFLECT 6509 TRUSS SUPPORT 2MI SEDIMENTATION CONTROL BARRIER - SILT FENCE SCALE: N.T.S MICROFLECT B501 12" WAVEGUIDE CHANNEL-REFER Z 0 w — I TO 8/C-3 MICROFLECT 8501 w �2 12" WIDE GALV, � 0 CHANNEL Es CL MICROFLECT B130 W ui 3 1/2"0 PIPE 0 -j MICROFLECT 81190 C> M PERMMnNG HALFSTRAP W/1/4"0 EQUIPMENT BUILDING WALL ONLY STAINLESS STEEL SCREW FINISHED GRADE 5 3/8*0 THREADED V", EQUIPMENT BUILDING FLOOR D M-� ROD W1 NUTS AND CONTRACTOR SHALL INSTALL NOT FOR CONSTRUCTION CONCRE11 TIE DOWN BRACKETS PROVIDED OVERSIZED WASHERS WALL BY EQUIPMENT BUILDING MANUFACTURER APPROXIMATE Q (a Q P1001 UNISTRUT 110 LOCATION OF 01 LL: CABLE SUPPORT I LEDGE 804. F04 04'-0* O.C. MAX -+ PROJECT NO: F301 41 CONCRETE COAXIAL CABLE W/ L--j ANDREW STAINLESS DRAWN BY: WJK A STEEL CABLE HANGER F­ NOTE: L 12-0 1 PROVIDt HOLES a 24"O.C. COORDINATE WITH BUILDING MANUFACTURER CHECKED BY: NOTE: -1 - W/NON- SHRINK GROUT AND FOR TIE DOWN BRACKET DETAJL AND LOCATIONS 2 1/219 MAXIMUM 10' SPACING BETWEEN POST SUPPORTS #5 DOWCI�s V-O" LONG ISSUED FOR '05-14-99 REVIEW CABLE SUPPORT DETAIL ��7 ICE BRIDGE DETAIL PIN FOUNDATION DETAIL BUILDING TIE DOWN DETAIL )6-09-99 ISSUED FOR PERM17NG SCALE: 1 1/2' V-0" SCALE: 1 V-0" I\L J, SCALE: 3/4" V-0" SCNLE: N.T.S. REFER TO C-2 FOR FINISHED SLAB ELEVATION FTHEINFORMATION CONTAINED I� ��j 5--0" IN THIS SET OF DOCUMENTS 6" CONCRETE SLAB REINFORCED WITH 6X6-W2.gXW2.9 W.W,F. IS PROPRIETARY BY NATURE. ON 8* MINIMUM COMPACTED ANY USE OR DISCLOSURE GRAVEL FILL 6" REINFORCED OTHER THAN THAT WHICH CONCRETE SLAB RELATES TO SNET IS —,vA SNET EQUIPMENT STRICTLY PROHIBITED. EQUIPMENT BUILDING BUILDING �-3 BY OTHERS F — — — I* INSULATION BOARD ISOLATOR Li 15 CORNER RECESS 1/2" BELOW SURFACE 1 CHAMFER (TYP.) F , LENNIE'S REINFORCEMENT OF CONCRETE AND SEAL 3 FIBERGLASS 2 -010 cr Lu #4 - 120 O.C. EACH WAY CN C C �3 IN j 1 11 --k I I x A A z 1804 MAIN ST. FINISHED GRADE AGAWAM, MA 01001 EQUIPMENT BUILDING FINISHED FLOOR dill /777 4 m )ft 4 1/80 SLOPE 2'-0 A FINISHED GRADE A 4 C-0-N-C- R-FT E CONCF�UE SCALE: AS NOTED A FOOTING cy A,OwP 2-#5 WALL STANDARD w 1 1 4 COMPACTED -tI z HOOK GRAVEL FILL 6 =.v UNDISTRUBED SOIL 0 w (Typ.) CONCRETE (n 14 4 4 1 -1 z CONCRETE WALL DATE: 05-14-99 FOUNDATION 4 — 8" COMPACTED GRAVEL FILL COMPACTED 6" 1.� 0" 6" WALL COMPACTED BACKFILL BACKFILL UNDISTURBED 2 CONCREUE DRAWING 4 OF 7 2 #5 REINFORCEMENT L FOOTING— SOIL LINE OF L - - - - - - - - - - - L�r c 1 J COMPACTED EXCAVATION -j 01 - FOUNDATION PLAN, BACKFILL 1111 3-#5 — ' - -------*-- � 0 .: r. - -- . V) jo- L — — — — — — — — — — — — — — — - -j hill NOTES AND NOTE! III 1110= 1141 '1�� HIM— 01111, 12'-0" DETAILS 1. BOTTOM OF FOOTING TO 13E A MINIMUM 4*-O"MIN-. COMPACTED OF 4'-0" BELOW FINISHED GRADE BACKFILL (VERIFY ALL DIMENSIONS WITH (TYPI) BUILDING REQUIREMENTS) Ilk ,k i v L ij r4"'� FOUNDATION CORNER DETAIL r3-,*%� FOUNDATION WALL DETAIL K�2 FOUNDATION DETAIL FOUNDATION PLAN C-3 �-3 SCALE: 3/4* V-0" SCALE: 3/4* V-0" SCALE: N,T.S. SCALE: 1/4" 1'-0"