To: Build in Dept.
CC: Planning/Con. Comm./Randy Campbell/File {
From: Engineering ��L 2 F,
Date: July 20, 2005
Subject: ' SP - 432 - MicroTest- Punch List
On Monday July 18, 2005, 2 members from Engineering visited the subject site to perform a
walk through inspection with Randy Campbell, the project superintendent for the subject site. There are
no significant deficiencies for utilities or site work. Engineering approves the release of the Certificate
of Occupancy.
It is recommended that the following items be addressed before the issuance of the Certificate of
Compliance by the Conservation Commission. These items pertain the wetland Order of Conditions.
Please see the attached list describing the completion of these items.
The trash racks for the outlet structures in each detention pond still have to be installed. They are
shown in the detention pond details. The installation of these racks should not affect Mr. Campbell's
work schedule ("completed week of 7/I 8/05"). The subject site has recently been hydro-seeded. The
establishment of vegetation+/or erosion repairs must occur at both detention ponds as required.
As per Mr. CampbelI's work schedule:
I. Water quality swale in northern detention pond has to be re-constructed as per plan.
2. Grout outlet pipe in south detention pond's outlet structure.
3. Mr. Campbell to submit letter certifying correct MA wetland seed mix used in detention ponds.
This mix to be re-applied again once north detention pond re-constructed.
4. Add stone and re-shape all rip-rap splash pads as per details.
5. In CB 2, hood not installed. Grout 6" inlet pipe.
1 6. The new hydrant needs a 6" extension.
Once again,the above listed items must be addressed before issuance of the Conservation
Committee's Certificate of Compliance.
If you have any questions,please do not hesitate to contact us.
Sincerely,
17 «z�
Rick S. Seidnitzer �frEn
e J oy ,P.E.
Civil Engineer I gineer
SASP1432 micro=W4_punch1ist.wpd
I
MAssDEVELOPMENT
Certified
160 Federal Street "
Boston,Massachusetts September 27, 2004
02110
Deborah Dachos
Tel:617-330-2000 planning Director
800-445-8030 Town of Agawam
36 Main Street
Fax:617-330-20N Agawam, MA 01001
617-451-3429
Dear Ms. Dachos:
wwwmassdtwelopmmLcom
On September 14, 2004 the Massachusetts Development Finance Agency gave preliminary
approval to issue a revenue bond on behalf of MicroTest Laboratories, Inc./MicroTest
Properties, LLC. The proposed project would be located in Agawam, Massachusetts at
the address(es) listed on the attached summary included for your information, The bond
would be issued pursuant to Chapter 23G and 40D of the General Laws.
Section 12(2) of Chapter 40D requires that the MassDevelopment (successor to the
MIFA) board "shall consult with the appropriate local and regional planning agencies to
ascertain the relationship of a proposed project to any existing state, local or regional
comprehensive plan."
MITT ROMNEY
Governor The purpose of this letter is to notify you of the project and to request that if the proposed
KERRY HEALEY project conflicts with an existing local or regional comprehensive plan, you so advise us.
Lieutenant Governor If you would like further information on the project, or if you would like the Board to
consider any comments you may have prior to our considering Final Approval on the
ROBERT L BEAL application, please give me a call.
Chairman
L.CutvEa Sincerely,
ROflERT
PresidentlCEO � ^
Laura L. Canter
Executive Vice President
Enclosure: Summary
cc. Shatz, Schwartz& Fentin, PC
1441 Main Street '- ` SEP 2 7 pq
Springfield, MA 01103
Attn: Gary Fentin, Esq.
LLC/cjk
®®I 09 Printed 0 paper mo+w(ammd a Massahusetrs
r .
Meeting Date: 9/14/2004
MICROTEST LABORATORIES, INCJMICROTEST PROPERTIES, LLC
NATURE OF To assist the applicant in financing an industrial project,
REQUEST: approval of the proposed project for a MassDevelopment Tax-
Exempt Industrial Development Bond issue is requested.
This project will need an allocation of state volume cap from
the Executive Office for Administration & Finance.
Borrower: Users :
MicroTest Laboratories, Inc./ MicroTest Laboratories, Inc.
MicroTest Properties, LLC 104 Gold Street
104 Gold Street Agawam, MA 01001
Agawam, MA 01001
LOCATION: 104 Gold Street
Agawam, MA 01001
PROJECT: Proposed is the purchase of land abutting the company's
existing building, construction of a 20,500 square foot addition
on the newly acquired parcel and the purchase of new
equipment. The proposed project will allow Microtest to meet
industry demand for pharmaceutical fill finish manufacturing.
GUIDELINE ISSUES: None
PROJECT COST: Land (4.5 acres) $67,000
Site Preparation 139,000
Addition (20,500 sq. ft.) 2,900,000
Equipment: (list attached) 1,921,000
Architectural & Engineering Costs 2,607,000
Fees and Expenses 555,000
Total Project Cost: $8,189,000
BOND AMOUNT: $5,000,000
EMPLOYMENT: Current employment at project site: 76
Projected new employment at project site: 57
1
GAPublic Record12004Wicroiest(OA).doc
COMPANY: MicroTest Laboratories, Inc. (MTL) was founded in 1983 by
Dr. Steven Richter as a contract microbiological testing
laboratory. MTL has expanded its business to include a
comprehensive array of analytical and chemical testing services
as well as pharmaceutical formulation fill finish drug
manufacturing. This process delivers purified bulk drugs to
MTL where they are appropriately formulated and aseptically
filled into smaller vials.
MicroTest is an ISO certified laboratory that meets both United
States Pharmacopeia and FDA requirements. Clients include
Abiomed; Johnson & Johnson; C.R. Bard; Boston Scientific;
Tambrands; Alcon Lays; Allergan; Genetic Institute; Genzyme;
Biogen; Immunex and many other prominent pharmaceutical,
biotech and medical devise manufacturers.
MicroTest Properties, LLC owns the real estate and leases the
building to MicroTest Laboratories, Inc. The companies have
identical ownership structures.
PUBLIC PURPOSE The proposed project will create 57 new jobs in an
BENEFIT: Economically Distressed Area.
PRINCIPALS: Steven G. Richter
BOARD ACTION: Make the statutory findings and approve the resolution
authorizing Official Action for a MassDevelopment Tax-
Exempt Industrial Development Bond.
2
GAPublic Recard120041Microtest(OA).doc
To wN of A GA WAM
MEMO]UNDUM
�0 MP
To: Planning Board
CC: File; John P. Stone, DPW Supt., Steven T. Dambrosio, Baystate Environmental
From: Engineering
Date: May 6, 2004
Subject: SP - 432 - Site Plan-MicroTest
Per your request of April 22, 2004 we have reviewed the Proposed Site Plan for Microtest Labs, Inc.
Facility Expansion 104 Gold Street, Agawam,MA; prepared by Baystate Environmental Consultants
Inc. 296 North Main Street, East Longmeadow, MA 01028; date: Dec.2003; Rev. 4/02/04; scale:
1"=30'.
The following comments were discussed with the site contractor Mr. Joe Frenette:
1. On the week of April 26't', 2004, the Department of Public Works had tested the existing 6" sewer
lateral from the existing sewer manhole at the end of the street located in the cul-de-sac. The purpose
was to determine the integrity of the pipe and the feasibility of using the existing sewer inverts already
established in the street. The DPW's field investigation found 58 feet of pipe located in the direction
of the proposed entrance/exit. Further site information such as the invert elevation at the end of the
58 feet would have to be located in the field and decided upon by the owner, engineer, and contractor
on using this existing sewer lateral. If the owner is planning on using this existing sewer lateral please
resubmit the site plan with any information pertaining these alterations to establish an accurate
depiction of the proposed work.
2. The DPW also found the existence of a 6" water lateral west of the existing sewer manhole in the
cul-de-sac that could become an option, if all engineering factors are considered, instead of the
proposed 8" water tap. If this change is made, please resubmit the site plan with any information
pertaining these alterations to establish an accurate depiction of the proposed work.
3. We approve of this revised site plan dated April 2, 2004.
If you have any questions, please do not hesitate to contact us.
Sincerely, Sincerely,
/" &4�n'J
Ge rganne J.Aoymffh, P.E. Adam S. Chase, E.I.T.
Town Engineer Civil Engineer I
i-E:1ENGMERWS 432103.wpd
•
MEMO
TO: Engineering Department
FROM: Planning Board
SUBJECT: Revised Plan - MicroTest - Gold Street
DATE: April 22, 2004
Please review the attached revised site plan for MicroTest on Gold Street to be sure it is ready
for the Board's signatures at their May 6`' meeting.
Thank you.
DSD:pre
Baystate Environme�l
Consultants, Inc.
296 North Main Street DATE: JOB NO.:
East Longmeadow, MA 01028 04/19/04 03-0508
ATTENTION;
(413) 525-3822 Deborah Dachos
FAX (413) 525-8348 RE:
MicroTest
TO: Planning Department _
Agawam Town Hall
36 Main Street
Agawam, MA 01001
WE ARE SENDING YOU El Attached ❑ Under separate cover via the following items:
❑ Shop Drawings ❑ Prints 0 Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑ Change order ❑
COPIES DATE NO. DESCRIPTION
3 Dec. '03 3 Shts Sheet-1: "Site Grading & Utilities Plan", Revision No. 7
Sheet-2: "Details", Revision No. 3
Sheet-3: "Details", Revision No. 1
THESE ARE TRANSMITTED as check below:
0 For approval ❑Approved as submitted ❑ Resubmit copies for approval
� For your use ❑ Approved as noted ❑ Submit copies for distribution
0 As requested ❑ Returned for correction ❑ Return corrected prints
❑ For review and comment ❑
❑ FOR BIDS DUE ❑ ITEMS RETURNED AFTER LOAN TO US
REMARKS
Attached please find 3 copies of plan set as requested, revised per 1/29/04 planning board comments.
tii 1%
11N
COPY TO: Bill Jenkins. MicroTest SIGNED: &11'i'l
Steve Conti, BioMetics
If enclosures are not as noted,kindly notify Zt-nce-
Town of Agawam
36 Main Street Agawam, Massachusetts 01001-1837
y
Tel. 413-786-0400 Fax 413-786-9927
I
ca
February 9, 2004
;y
Steven G. Richter
Micro-Test Labs, Inc. co rn
104 Gold Street `N
Agawam, MA 01001
Dear Mr. Richter: '
At its duly called meeting held on January 29, 2004,the Agawam Planning Board voted to approve
the Site Plan entitled"Microtest Labs Inc. Facility Expansion, Microtest Labs,Inc., 104 Gold Street,
Agawam, Massachusetts" prepared by Baystate Environmental Consultants, Inc. and dated
December 2003 and revised January 26, 2004 with the following conditions:
1 The type,height and wattage ofthe exterior lighting to be used is to be submitted to
the Planning Board for their approval.
2. The dumpster location is to be shown on the plan specifying that the dumpster is to
be screened, fenced and gated.
3. The following landscape note is to be provided on the plan: "All plantings must be
maintained and that portion of the public way abutting the parcel and.including the
treebeit shall be maintained in a safe and attractive condition by the owner of the
parcel."
4. The Engineering comments contained in the Engineering memo dated January 29,
2004 and attached must be addressed. j
5. There shall be a minimum of 33 parking spaces provided on site during construction.
Construction workers are to be provided parking on site off of the traveled way.
i
I
• •
Three copies of the revised plan are to be submitted to the Planning Board for its signatures. If you i
have any questions, please contact the Planning Office at 786-0400, extension 283.
Sincerely,
i
Dennis B. Hopkins, Chairman
Agawam Planning Board
cc: Clerk
Baystate Environmental
Engineering
Building
File
i
i
i
i
i
1
TowNoj 4GAWAM'
MEMORz4N" D Uhl '
To: Planning Board
CC: File; John P. Stone, DPW Supt., Steven.T. Dambrosio, Baystate Environmental
From: Engineering
Date: January 29, 2004
Subject: SP - 432 - Site Plan- MicroTest
Per your request of January 8, 2004 we have reviewed the Proposed Site Plan for Microtest Labs,
Inc. Facility Expansion 104 Gold Street, Agawam, MA; prepared by Baystate Environmental
Consultants tnc. 296 North Main Street, East Longmeadow, MA 01028; date: Dec.2003; Rev.
1/26/04; scale: 1"=30' and have the following additional comments:
Baystate Environmental has addressed the previous comments 1 thru 7 from our memorandum
sent on January 15, 2004. Once the site plan is approved the owner will address comments 8 and 9
which describe what permits are needed.
The only remaining issue is the proposed grading located within the Tennessee Gas Pipeline
Company's,easement. Before approval of any site plan and drainage calculations by Engineering, the
owner should provide a formal statement from Tennessee Gas Pipeline Company which approves of
the proposed construction including a description of any restrictions they will require.
Attached is the memorandum from January 15, 2004.
If you have any questions, please do not hesitate to contact us.
S' cerely, Sincerelf. ,
Iorgann . Ho an, P.E. Adam S. Chase, E.LT.
wn Engineer Civil Engineer I
H:IENG INEERW\432\02.wpd
V
To WN oFA' GA. wAm r �,
MEMORANDUM
- 1
1
1
To: Planning Board
CC: File; Steven T. Dambrosio, Baystate Environmental
From: Engineering
Date: January 15, 2004
1
Subject: SP - 432 - Site Plan - MicroTest
Per your request of January 8, 2004 we have reviewed the Proposed Site Plan for Microtest Labs,
Inc.Facility Expansion 104 Gold Street, Agawam, MA;prepared by Baystate Environmental
Consultants Inc. 296 North Main Street, East Longmeadow, MA 01028; date: Dec.2003; Rev..
1/06/04; Rev 1/08/04; scale: 1"=30' and have the following additional comments:
1. We request one benchmark be shown on the plan.
2. With the expansion of the parking lot and the new proposed access road to the cul-de-sac we
recommend adding some type of travel direction pavement markings and/or signs within the parking
lot.
3. We recommend a minimum of 3 to 1 slopes wherever there is proposed re-grading. Since the two ,
detention ponds have 2 to 1 slopes, and the drainage calculations have been approved slope
stabilization measures should be implemented as needed.
4. Please show the type of curb on the plan to be used on the radius near the cul-de-sac for the curb
cut portion. We recommend using a Bituminous Concrete Berm Type-II (9" wide by 6 1/2" reveal)
to.match the existing.
5. A minimum of 5 feet in depth for all water service piping should be shown on the plan.
6. The following notes should be added to the plans:
"Prior to any installation of any sewer, water or drainage lines, the contractor/owner shall contact
the Town of Agawam's Engineering Division, 786-0400 x 275/8.. No pip ing/appurteriarices will be
installed or backfilled without the permission of the division."
"The contractor/owner shall be responsible for testing any existing Town gate valve where a new
connection will be made. The contractor/owner will also be responsible for repairing or replacing
such.valve or installing a new valve at the property line in order-to allow pressure testing of the new
water main."
7. We have certain standard details we use within the Town. The following details will be sent over
to you digitally in AutoCAD format for your use to include in the detail sheet: Sanitary Sewer
Manhole, Concrete Collar, Sanitary Sewer Manhole Frame and Cover, Hydrant Detail, Building
Sewer Connection, Permanent Pavement Replacement Detail, Wheel Chair Ramp (bounds not
needed), and Thrust Restraints Field Lok Gaskets. Please add a Bituminous�Concrete Berm Type-II
detail since our version is only included in the Typical Roadway Section.
8. The following permits are needed and can be picked up at the Department of Public Works:
Storm Drain Permit, Road Opening Permit, and a Curb Cut Permit.
9. A Sewer Extension Permit maybe required depending on the design flow of the expansion. Please,
consult the Department of Environmental Protection regulations. If it is required, construction on the
sanitary sewer connection may not begin until the D.E.P. approval is received.
If you have any questions, please do not hesitate to contact us. 1
Sincerely, Sincerely- .A A. �41A!V�
e . Ho an, P.E. Adam S. Chase, E.I.T.
rganne
T n Engineer Civil Engineer x
H AENG II MMSA4J2101.wpd
I
I
I
' I
II
. I
I
11
' I
• I
I
• a
I
\ I
I
II
I
AGAWAM OFFICE OF PLANNING & COMMUNITY DEVELOPMENT
SITE PLAN REVIEW
REVIEWER: D. Dachos DATE: January 29, 2004
DATE RECEIVED: January 7, 2004 DISTRIBUTION DATE: January 8, 2004
PLANNING BOARD MEETING DATE. January 29, 2004
APPLICANT INFORMATION
1. Name of Business: Micro-Test Labs, Inc.
Address: 104 Gold Street, Agawam, MA
2. Owner: Steven G. Richter
Address: Same
Telephone: Fax:
3. Engineer: Baystate Environmental Consultants, Inc.
Address: 296 North Main Street, East Longmeadow, MA 01028
Telephone: 413-525-3822 Fax:
PLAN REVIEW
Scale: 1" = 30' Date: December 2003
Title Block (Street Address, Applicant's Name, Address, Scale, Name of Preparer of Plan):
O.K.
Description of Project: Proposed construction of a 15,000 sq. ft. addition to an existing
building and associated utilities and parking.
Site Plan Review
Page 2
Description of Site: Site is presently undeveloped. An Order of Conditions has been
issued by the Agawam Conservation Commission.
Provision for Traffic Flow: Unchanged.
Parking: It is unclear how many new parking spaces are being created. After
construction there will be a total of 80 spaces. The parking guidelines recommend 1
space for every 1.5 employees on a major shift.
Drainage: See Engineering comments.
Public Utilities: See Engineering comments.
Landscaping/Screening and Buffers: The following landscape note must be placed on the
plan: "All plantings must be maintained and that portion of the public way abutting the
parcel and including the treebelt shall be maintained in a safe and attractive condition by
the owner of the parcel."
Sign Location: Unchanged.
Exterior Lighting: All exterior lighting must be shown on the plan.
Rendering or Elevations: Not provided.
Dumpster Location: Not shown.
Other Comments or Concerns:
Baystate Environmeo.l
Consultants, Inc.
296 North Main Street DATE: JOB NO.:
East Longmeadow, MA 01028 01/29/04 03-0508
ATTENTION;
(413) 525-3822 Deborah Dachos
FAX (413) 525-8348 RE:
MicroTest
TO: _Planning Department
Agawam_ Town Hall
36 Main Street
Agawam, MA 01001
WE ARE SENDING YOU ❑X Attached ❑ Under separate cover via the following items:
❑ Shop Drawings ❑ Prints ❑x Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑Change order ❑
COPIES DATE NO. DESCRIPTION
3 Dec. '03 2 Shts Sheet-1. "Site Grading & Utilities Plan", Revision No. 4
Sheet-2: "Details", Revision No. 2
3 Jan. `04 1 Shts Sheet-3: "Details"
THESE ARE TRANSMITTED as check below:
® For approval ❑Approved as submitted ❑ Resubmit copies for approval
❑For your use ❑Approved as noted ❑ Submit copies for distribution
❑As requested ❑Returned for correction ❑ Return corrected prints
❑For review and comment ❑
❑FOR BIDS DUE ❑ ITEMS RETURNED AFTER LOAN TO US
REMARKS
These copies are being sent to ensure that the Town of Agawam Planning Board has the most current
plan set. - _ -- - —-
COPY TO: : SIGNED:
1 U .o
If enclosures are not as noted,kindly notify us at once.
To wN of A GA wAm' OD
1�lEMORANDUM
To: Planning Board
CC: File; John P. Stone, DPW Supt., Steven T. Dambrosio, Baystate Environmental
From: Engineering
Date: January 29, 2004
Subject: SP - 432 - Site Plan- MicroTest
Per your request of January 8, 2004 we have reviewed the Proposed Site Plan for Microtest Labs,
Inc. Facility Expansion 104 Gold Street, Agawam, MA; prepared by Baystate Environmental
Consultants Inc. 296 North Main Street, East Longmeadow, MA 01028; date: Dec.2003; Rev.
1/26/04; scale: I"=30' and have the following additional comments:
Baystate Environmental has addressed the previous comments 1 thru 7 from our memorandum
sent on January 15, 2004. Once the site plan is approved the owner will address comments 8 and 9
which describe what permits are needed.
The only remaining issue is the proposed grading located within the Tennessee Gas Pipeline
Company's easement. Before approval of any site plan and drainage calculations by Engineering, the
owner should provide a formal statement from Tennessee Gas Pipeline Company which approves of
the proposed construction including a description of any restrictions they will require.
Attached is the memorandum from January 15, 2004.
If you have any questions, please do not hesitate to contact us.
Si cerely, Sincerely,
Iorgann . Ho an, P.E. Adam S. Chase, E.I.T.
wn Engineer Civil Engineer I
H:\ENG1NUER\SP1432\D2-wpd
To TAN oF A GA wAm
MEMORANDUM 0"'P'
To: Planning Board
CC: File; Steven T. Dambrosio, Baystate Environmental
From: Engineering
Date: January 15, 2004
Subject: SP - 432 - Site Plan - MicroTest
Per your request of January 8, 2004 we have reviewed the Proposed Site Plan for Microtest Labs,
Inc. Facility Expansion 104 Gold Street, Agawam, MA; prepared by Baystate Environmental
Consultants Inc. 296 North Main Street, East Longmeadow, MA 01028; date: Dec.2003; Rev.
1/06/04; Rev 1/08/04; scale: 1"=30' and have the following additional comments:
1. We request one benchmark be shown on the plan.
2. With the expansion of the parking lot and the new proposed access road to the cul-de-sac we
recommend adding some type of travel direction pavement markings and/or signs within the parking
lot.
3. We recommend a minimum of 3 to 1 slopes wherever there is proposed re-grading. Since the two
detention ponds have 2 to 1 slopes, and the drainage calculations have been approved slope
stabilization measures should be implemented as needed.
4. Please show the type of curb on the plan to be used on the radius near the cul-de-sac for the curb
cut portion. ,We recommend using a Bituminous Concrete Berm Type-H (9" wide by 6 1/2" reveal)
to match the existing.
5. A minimum of 5 feet in depth for all water service piping should be shown on the plan.
6. The following notes should be added to the plans:
"Prior to any installation of any sewer, water or drainage lines, the contractor/owner shall contact
the Town of Agawam's Engineering Division, 786-0400 x 275/8. No piping/appurtenarices will be
installed or backfilled without the permission of the division."
"The contractor/owner shall be responsible for testing any existing Town gate valve where a new
connection will be made. The contractor/owner will also be responsible for repairing or replacing
such valve or installing a new valve at the property line in order to allow pressure testing of the new
water main."
7. We have certain standard details we use within the Town. The following details will be sent over
to you digitally in AutoCAD format for your use to include in the detail sheet: Sanitary Sewer
Manhole, Concrete Collar, Sanitary Sewer Manhole Frame and Cover, Hydrant Detail, Building
Sewer Connection, Permanent Pavement Replacement Detail, Wheel Chair Ramp (bounds not
needed), and Thrust Restraints Field Lok Gaskets. Please add a Bituminous_Concrete Berra Type-H
detail since our version is only included in the Typical Roadway Section.
8. The following permits are needed and can be picked up at the Department of Public Works:
Storm Drain Permit, Road Opening Permit, and a Curb Cut Permit.
r
• •
9. A Sewer Extension Permit maybe required depending on the design flow of the expansion. Please
consult the Department of Environmental Protection regulations. If it is required, construction on the
sanitary sewer connection may not begin until the D.E.P. approval is received.
If you have any questions, please do not hesitate to contact us.
Sincerely, Sincerely,
A 1jAA_A-1-j rl-MYA -
e rganne j Ho an, P.E. Adam S. Chase, E.I.T.
T n Engineer Civil Engineer I
HAEI`C NEERLSP141210 1.wpd
PVTO TAN of A GA WAM
1Y
MEMORANDUM
To: Planning Board
CC: File; Steven T. Dambrosio, Baystate Environmental
From: Engineering
ft, r r�ryv9
Date: January 15, 2004 ��;• � �� `� 0 1
Subject: SP - 432 - Site Plan - MicroTest
Per your request of January 8, 2004 we have reviewed the Proposed Site Plan�ofQicrotest Labs,
Inc. Facility Expansion 104 Gold Street, Agawam, MA; prepared by Baystate Environmental
Consultants Inc. 296 North Main Street, East Longmeadow, MA 01028; date: Dec.2003; Rev.
1/06/04; Rev 1/08/04; scale: 1"=30' and have the following additional comments:
1. We request one benchmark be shown on the plan.
2. With the expansion of the parking lot and the new proposed access road to the cul-de-sac we
recommend adding some type of travel direction pavement markings and/or signs within the parking
lot.
3. We recommend a minimum of 3 to 1 slopes wherever there is proposed re-grading. Since the two
detention ponds have 2 to 1 slopes, and the drainage calculations have been approved slope
stabilization measures should be implemented as needed.
4. Please show the type of curb on the plan to be used on the radius near the cul-de-sac for the curb
cut portion. •We recommend using a Bituminous Concrete Berm Type-11 (9" wide by 6 1/2" reveal)
to match the existing.
5. A minimum of 5 feet in depth for all water service piping should be shown on the plan.
6. The following notes should be added to the plans:
"Prior to any installation of any sewer, water or drainage lines, the contractor/owner shall contact
the Town of Agawam's Engineering Division, 786-0400 x 275/8. No piping/appurtenahces will be
installed or backfilled without the permission of the division."
"The contractor/owner shall be responsible for testing any existing Town gate valve where a new
connection will be made. The contractor/owner will also be responsible for repairing or replacing
such valve or installing a new valve at the property line in order to allow pressure testing of the new
water main."
7. We have certain standard details we use within the Town. The following details will be sent over
to you digitally in AutoCAD format for your use to include in the detail sheet: Sanitary Sewer
Manhole, Concrete Collar, Sanitary Sewer Manhole Frame and Cover, Hydrant Detail, Building
Sewer Connection, Permanent Pavement Replacement Detail, Wheel Chair Ramp (bounds not
needed), and Thrust Restraints Field Lok Gaskets. Please add a Bituminous Concrete Berm Type-H
detail since our version is only included in the'Typical Roadway Section.
8. The following permits are needed and can be picked up at the Department of Public Works:
Storm Drain Permit, Road Opening Permit, and a Curb Cut Permit.
OV9. A Sewer Extension Permit may be required depending on the design flow of the expansion. Please
consult the Department of Environmental Protection regulations. If it is required, construction on the
sanitary sewer connection may not begin until the D.E.P. approval is received.
If you have any questions, please do not hesitate to contact us.
Sincerely, Sincerely,
`1
e rganne j Ho an, P.E. Adam S. Chase, E.I.T.
T n Engineer Civil Engineer I
H AF.NG1NEER1sP143210].wpd
1
0
Memo
To: Planning Board
From: Sgt. Donald Galleran �
Subject: Site Plan - Microtest - Gold Street
Date: January 14, 2004
The site plan from Microtest Labs to build a 15,000 square foot addition to their already existing
building should have no impact on pedestrian or traffic safety.
However, they must be in compliance with the Town Ordinance regarding Handicapped Parking.
5 i
�a AGAWAM FIFE DEPARTMENT
800 MAIN STREET 0 AGAWAM, MA 01001 Q V NT
TELEPHONE (413) 786-0657
FAX (413) 786-1241
David A. Pisano Chief of Department
Stephen M. Martin Deputy Chief FfRES
�D
RE: MICRO-TEST LABS, INC. 1/12/04
104 GOLD ST.
As per. 780,527,and521 C.M.R.s and 148 M.G.L. and N.F.P.A. 13 and 72 this addition shall be
sprinkled, and alarmed. Please note that the hydrant must be located with in(100) ft. Of the fire
department connection and all alarm wiring must be MC or in CONDUIT where it is not
otherwise protected. Complete Narratives, Drawings, and Calculations, shall be submitted along
with a copy of the sprinkler installers license before work is to begin. Also be advised that paved
access to these structures is required.
Fire Insp. M.Mercadante
Town of Agawam
36 Main Street Agawam, Massachusetts 01001-1837
y� 1�
p MP
Tel, 413-786-0400 Fax 413-786-9927
MEMO
TO: Engineering Dept., Police Dept., Fire Dept.
FROM: Planning Board
SUBJECT: Site Plan - Microtest - Gold Street
DATE: January 8, 2004
Please review and comment on the attached Site Plan for Microtest on Gold Street prior to the
Board's January 15, 2004 meeting.
Thank you.
DSD:pre
33 14135258348 BAYSTATE ENV WS
PAGE 02/02
J.�..i V� JV i t L'1 t tt/i Wt n 1 ✓IL 1
1 VV VJL
AGAWAM PLANNINQ BOARD
Form D
Application for Site Plan Approval
Please complete the following form and return it and 10 copies of the Site Plan to:
Agawam Building Department
36 Maid Street
Agawam, MA 01001
1. Name of 3usiness Micro-Teat Labs, Inc.
Addzcss _ 104 Gold Street, Asaawam MA
Telephone 413-786-1680 fax
2. Narus of Applicant/Ownor'Steven Q._Richter (owner)
Address c/o Micro--Test .Labs, Inc.
Telephone Fax
3. Name of Engil3ecrlArcli tect Bay.atate Environmental Consultants, Inc_
Address 296 North Main Street;_East Longmeadow, MA 01028
�G�46
Telephone 413-525-3822 Fax 413-525-38272
4. Please give a brief description of the proposed project:
Froposed 15,000 square foot building addition with associated
site utilities and parking.
Rrvised 8114103
TOML P.0-1
Baystate Enviro*ntal
Consultants, Inc.
296 North Main Street
East Longmeadow, MA 01028 DATE JOB NO.
01/06/04 03-0508
ATTENTION
(413) 525-3822
FAX (413) 525-8348 RE; Micro-Test Labs, Inc.
TO: Town of Agawam o
Planning Board
c_
p Cr Q
p
WE ARE SENDING YOU 0 Attached [I Under separate cover via th vlowlg it ts:
❑ Shop Drawings ❑ Prints I] Plans ❑ Samples ❑ Specific ns v? rr„
❑ Copy of Letter ❑ Change Order❑ x:_ 7
COPIES DATE NO. DESCRIPTION
10 12/03 Revised Site Plans, Sheets 1-2 of 2, Revision No. 1, 01/06/04
THESE ARE TRANSMITTED as check below:
❑ For approval ❑ Approved as submitted ❑ u `iti cb_pies for approval
❑ For your use ❑ Approved as noted ❑ copies for distribution
❑ As requested ❑ Returned for correction ❑ Return corrected prints
ID For review and comment❑
❑ FOR BIDS DUE ❑ ITEMS RETURNED AFTER LOAN TO US
REMARKS
.l r
ro
f.J
COPY TO: Bill Jenkins—Micro-Test Labs, Inc. -SIGNED: Tom Jenkins, P.E.
/f enclosures are not as noted,kindly nodfy us at once
JOB a can L4-(.P
LOGS a( a Qs
Box # A
DOCUMENT#
PAGE# � D